Cargando…

Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy

PURPOSE: To compare anterior segment parameters in patients with Fuchs endothelial dystrophy (FED) who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) in one eye and no corneal surgery in the fellow eye. METHODS: This prospective study was conducted on 28 eyes of 14 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Karadag, Remzi, Hammersmith, Kristin M., Nagra, Parveen K., Rapuano, Christopher J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PUBLISHED BY KNOWLEDGE E 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8126739/
https://www.ncbi.nlm.nih.gov/pubmed/34055252
http://dx.doi.org/10.18502/jovr.v16i2.9078
_version_ 1783693826997616640
author Karadag, Remzi
Hammersmith, Kristin M.
Nagra, Parveen K.
Rapuano, Christopher J.
author_facet Karadag, Remzi
Hammersmith, Kristin M.
Nagra, Parveen K.
Rapuano, Christopher J.
author_sort Karadag, Remzi
collection PubMed
description PURPOSE: To compare anterior segment parameters in patients with Fuchs endothelial dystrophy (FED) who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) in one eye and no corneal surgery in the fellow eye. METHODS: This prospective study was conducted on 28 eyes of 14 patients with FED who underwent DSAEK in one eye at least one year prior (DSAEK group) and no corneal surgery in the fellow eye (control group). Each eye was analyzed with the anterior segment optical coherence tomography, specular microscopy, and Scheimpflug imaging systems. Data were compared between the two groups. RESULTS: The mean age of the patients was 76.9 [Formula: see text] 7.0 years. There were no statistically significant differences in the mean central corneal thickness (CCT), central anterior chamber depth, anterior chamber angle parameters, cylinder and keratometry values between two groups (all P-values [Formula: see text] 0.05). The paracentral corneal thickness, corneal volume, endothelial cell density, and hexagonal cell ratio measurements were statistically significantly higher in the DSAEK group than the control (all P-values < 0.05), and anterior chamber volume in the DSAEK group was significantly less than the control (P = 0.046). While posterior and total corneal densitometry values in the DSAEK group were statistically significantly lower than the control (P < 0.001 and P = 0.011, respectively), there were no statistically significant differences in the anterior or middle corneal densities (P = 0.108 and P = 0.134, respectively). CONCLUSION: We found that total corneal densitometry value decreased in DSAEK group. Although DSAEK surgery did not affect the anterior chamber angle parameters, it reduced the anterior chamber volume and increased the corneal volume and paracentral corneal thickness due to the addition of the DSAEK graft.
format Online
Article
Text
id pubmed-8126739
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher PUBLISHED BY KNOWLEDGE E
record_format MEDLINE/PubMed
spelling pubmed-81267392021-05-27 Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy Karadag, Remzi Hammersmith, Kristin M. Nagra, Parveen K. Rapuano, Christopher J. J Ophthalmic Vis Res Original Article PURPOSE: To compare anterior segment parameters in patients with Fuchs endothelial dystrophy (FED) who underwent Descemet stripping automated endothelial keratoplasty (DSAEK) in one eye and no corneal surgery in the fellow eye. METHODS: This prospective study was conducted on 28 eyes of 14 patients with FED who underwent DSAEK in one eye at least one year prior (DSAEK group) and no corneal surgery in the fellow eye (control group). Each eye was analyzed with the anterior segment optical coherence tomography, specular microscopy, and Scheimpflug imaging systems. Data were compared between the two groups. RESULTS: The mean age of the patients was 76.9 [Formula: see text] 7.0 years. There were no statistically significant differences in the mean central corneal thickness (CCT), central anterior chamber depth, anterior chamber angle parameters, cylinder and keratometry values between two groups (all P-values [Formula: see text] 0.05). The paracentral corneal thickness, corneal volume, endothelial cell density, and hexagonal cell ratio measurements were statistically significantly higher in the DSAEK group than the control (all P-values < 0.05), and anterior chamber volume in the DSAEK group was significantly less than the control (P = 0.046). While posterior and total corneal densitometry values in the DSAEK group were statistically significantly lower than the control (P < 0.001 and P = 0.011, respectively), there were no statistically significant differences in the anterior or middle corneal densities (P = 0.108 and P = 0.134, respectively). CONCLUSION: We found that total corneal densitometry value decreased in DSAEK group. Although DSAEK surgery did not affect the anterior chamber angle parameters, it reduced the anterior chamber volume and increased the corneal volume and paracentral corneal thickness due to the addition of the DSAEK graft. PUBLISHED BY KNOWLEDGE E 2021-04-29 /pmc/articles/PMC8126739/ /pubmed/34055252 http://dx.doi.org/10.18502/jovr.v16i2.9078 Text en Copyright © 2021 Karadag et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. which permits unrestricted use and redistribution provided that the original author and source are credited.
spellingShingle Original Article
Karadag, Remzi
Hammersmith, Kristin M.
Nagra, Parveen K.
Rapuano, Christopher J.
Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title_full Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title_fullStr Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title_full_unstemmed Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title_short Anterior Chamber Characteristics, Endothelial Parameters, and Corneal Densitometry After Descemet Stripping Automated Endothelial Keratoplasty in Patients With Fuchs Dystrophy
title_sort anterior chamber characteristics, endothelial parameters, and corneal densitometry after descemet stripping automated endothelial keratoplasty in patients with fuchs dystrophy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8126739/
https://www.ncbi.nlm.nih.gov/pubmed/34055252
http://dx.doi.org/10.18502/jovr.v16i2.9078
work_keys_str_mv AT karadagremzi anteriorchambercharacteristicsendothelialparametersandcornealdensitometryafterdescemetstrippingautomatedendothelialkeratoplastyinpatientswithfuchsdystrophy
AT hammersmithkristinm anteriorchambercharacteristicsendothelialparametersandcornealdensitometryafterdescemetstrippingautomatedendothelialkeratoplastyinpatientswithfuchsdystrophy
AT nagraparveenk anteriorchambercharacteristicsendothelialparametersandcornealdensitometryafterdescemetstrippingautomatedendothelialkeratoplastyinpatientswithfuchsdystrophy
AT rapuanochristopherj anteriorchambercharacteristicsendothelialparametersandcornealdensitometryafterdescemetstrippingautomatedendothelialkeratoplastyinpatientswithfuchsdystrophy