Cargando…

Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era

To evaluate the problems in doing emergency tracheostomy and tracheostomy care of patients with unknown COVID-19 status. Study the usefulness of the specially designed Tracheostomy Shield. A prospective hospital-based study was conducted at a tertiary care center in India treating COVID and Non COVI...

Descripción completa

Detalles Bibliográficos
Autores principales: Kirti, Y. K., Soni, Smita, Yashveer, J. K., Anjali, A. R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer India 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8128088/
https://www.ncbi.nlm.nih.gov/pubmed/34026594
http://dx.doi.org/10.1007/s12070-021-02632-7
_version_ 1783694052568334336
author Kirti, Y. K.
Soni, Smita
Yashveer, J. K.
Anjali, A. R.
author_facet Kirti, Y. K.
Soni, Smita
Yashveer, J. K.
Anjali, A. R.
author_sort Kirti, Y. K.
collection PubMed
description To evaluate the problems in doing emergency tracheostomy and tracheostomy care of patients with unknown COVID-19 status. Study the usefulness of the specially designed Tracheostomy Shield. A prospective hospital-based study was conducted at a tertiary care center in India treating COVID and Non COVID patients. The study was done from April 2020 to December 2020. A total of 80 tracheostomy were done using Tracheostomy shield. Open tracheostomies were 38 while 42 patients were already intubated (closed circuit). The Tracheostomy shield was also used in 380 tracheostomy tubes changes. Two patients were found COVID positive on RT-PCR after tracheostomy. There was no scope for testing all tube changes with RT-PCR. The use of our indigenously designed Tracheostomy shield has been effective in reducing the aerosol spread and there was no COVID transmission reported. The use of patient Tracheostomy shield is of uttermost importance in reducing the respiratory droplets splashing on to the surgeon and assistant while doing awake tracheostomy. It is extremely useful while changing tubes as there are chances of false negatives antigen test which might be miss leading. The use of Tracheostomy shield is very important in the current context of new and fast evolving respiratory infections.
format Online
Article
Text
id pubmed-8128088
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer India
record_format MEDLINE/PubMed
spelling pubmed-81280882021-05-18 Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era Kirti, Y. K. Soni, Smita Yashveer, J. K. Anjali, A. R. Indian J Otolaryngol Head Neck Surg Original Article To evaluate the problems in doing emergency tracheostomy and tracheostomy care of patients with unknown COVID-19 status. Study the usefulness of the specially designed Tracheostomy Shield. A prospective hospital-based study was conducted at a tertiary care center in India treating COVID and Non COVID patients. The study was done from April 2020 to December 2020. A total of 80 tracheostomy were done using Tracheostomy shield. Open tracheostomies were 38 while 42 patients were already intubated (closed circuit). The Tracheostomy shield was also used in 380 tracheostomy tubes changes. Two patients were found COVID positive on RT-PCR after tracheostomy. There was no scope for testing all tube changes with RT-PCR. The use of our indigenously designed Tracheostomy shield has been effective in reducing the aerosol spread and there was no COVID transmission reported. The use of patient Tracheostomy shield is of uttermost importance in reducing the respiratory droplets splashing on to the surgeon and assistant while doing awake tracheostomy. It is extremely useful while changing tubes as there are chances of false negatives antigen test which might be miss leading. The use of Tracheostomy shield is very important in the current context of new and fast evolving respiratory infections. Springer India 2021-05-17 2022-10 /pmc/articles/PMC8128088/ /pubmed/34026594 http://dx.doi.org/10.1007/s12070-021-02632-7 Text en © Association of Otolaryngologists of India 2021
spellingShingle Original Article
Kirti, Y. K.
Soni, Smita
Yashveer, J. K.
Anjali, A. R.
Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title_full Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title_fullStr Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title_full_unstemmed Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title_short Novel Use of Tracheostomy Shield for Emergency Tracheostomy in Covid 19 Era
title_sort novel use of tracheostomy shield for emergency tracheostomy in covid 19 era
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8128088/
https://www.ncbi.nlm.nih.gov/pubmed/34026594
http://dx.doi.org/10.1007/s12070-021-02632-7
work_keys_str_mv AT kirtiyk noveluseoftracheostomyshieldforemergencytracheostomyincovid19era
AT sonismita noveluseoftracheostomyshieldforemergencytracheostomyincovid19era
AT yashveerjk noveluseoftracheostomyshieldforemergencytracheostomyincovid19era
AT anjaliar noveluseoftracheostomyshieldforemergencytracheostomyincovid19era