Cargando…
Endothelial glycocalyx during early reperfusion in patients undergoing cardiac surgery
BACKGROUND: Experimental cardiac ischemia-reperfusion injury causes degradation of the glycocalyx and coronary washout of its components syndecan-1 and heparan sulfate. Systemic elevation of syndecan-1 and heparan sulfate is well described in cardiac surgery. Still, the events during immediate reper...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8128269/ https://www.ncbi.nlm.nih.gov/pubmed/33999952 http://dx.doi.org/10.1371/journal.pone.0251747 |
Sumario: | BACKGROUND: Experimental cardiac ischemia-reperfusion injury causes degradation of the glycocalyx and coronary washout of its components syndecan-1 and heparan sulfate. Systemic elevation of syndecan-1 and heparan sulfate is well described in cardiac surgery. Still, the events during immediate reperfusion after aortic declamping are unknown both in the systemic and in the coronary circulation. METHODS: In thirty patients undergoing aortic valve replacement, arterial concentrations of syndecan-1 and heparan sulfate were measured immediately before and at one, five and ten minutes after aortic declamping (reperfusion). Parallel blood samples were drawn from the coronary sinus to calculate trans-coronary gradients (coronary sinus–artery). RESULTS: Compared with immediately before aortic declamping, arterial syndecan-1 increased by 18% [253.8 (151.6–372.0) ng/ml vs. 299.1 (172.0–713.7) ng/ml, p < 0.001] but arterial heparan sulfate decreased by 14% [148.1 (135.7–161.7) ng/ml vs. 128.0 (119.0–138.2) ng/ml, p < 0.001] at one minute after aortic declamping. There was no coronary washout of syndecan-1 or heparan sulfate during reperfusion. On the contrary, trans-coronary sequestration of syndecan-1 occurred at five [-12.96 ng/ml (-36.38–5.15), p = 0.007] and at ten minutes [-12.37 ng/ml (-31.80–6.62), p = 0.049] after reperfusion. CONCLUSIONS: Aortic declamping resulted in extracardiac syndecan-1 release and extracardiac heparan sulfate sequestration. Syndecan-1 was sequestered in the coronary circulation during early reperfusion. Glycocalyx has been shown to degrade during cardiac surgery. Besides degradation, glycocalyx has propensity for regeneration. The present results of syndecan-1 and heparan sulfate sequestration may reflect endogenous restoration of the damaged glycocalyx in open heart surgery. |
---|