Cargando…

Impact of slice thickness, pixel size, and CT dose on the performance of automatic contouring algorithms

PURPOSE: To investigate the impact of computed tomography (CT) image acquisition and reconstruction parameters, including slice thickness, pixel size, and dose, on automatic contouring algorithms. METHODS: Eleven scans from patients with head‐and‐neck cancer were reconstructed with varying slice thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Kai, Rhee, Dong Joo, Ger, Rachel, Layman, Rick, Yang, Jinzhong, Cardenas, Carlos E., Court, Laurence E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130223/
https://www.ncbi.nlm.nih.gov/pubmed/33779037
http://dx.doi.org/10.1002/acm2.13207