Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony®
PURPOSE: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un‐flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work w...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130229/ https://www.ncbi.nlm.nih.gov/pubmed/33779041 http://dx.doi.org/10.1002/acm2.13234 |
_version_ | 1783694471382171648 |
---|---|
author | Ferris, William S. Culberson, Wesley S. Smilowitz, Jennifer B. Bayouth, John E. |
author_facet | Ferris, William S. Culberson, Wesley S. Smilowitz, Jennifer B. Bayouth, John E. |
author_sort | Ferris, William S. |
collection | PubMed |
description | PURPOSE: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un‐flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work was to assess the impact of the variable‐width aperture on delivered dose using measurements and simulations. METHODS: Longitudinal beam profile measurements were acquired using an Edge diode with static gantry. Jaw‐offset peak, width, and integral factors were calculated for profiles with the jaws in the extreme positions using both variable‐width (Synchrony) and fixed‐width apertures. Treatment plans with target motion and compensation were compared to planned doses to study the impact of the variable aperture on volumetric dose. RESULTS: The jaw offset peak factor (JOPF) for the Synchrony jaw settings were 0.964 and 0.983 for the 1.0‐ and 2.5‐cm jaw settings, respectively. These values decreased to 0.925 and 0.982 for the fixed‐width settings, indicating that the peak value of the profile would decrease by 7.5% compared to centered if the aperture width was held constant. The IMRT dose distributions reveal similar results, where gamma pass rates are above tolerance for the Synchrony jaw settings but fall significantly for the fixed‐width 1‐cm jaws. CONCLUSIONS: The variable‐width behavior of Synchrony jaws provides a larger output correction for the 1‐cm jaw setting. Without the variable‐aperture correction, plans with the 1‐cm jaw setting would underdose the target if the jaws spend a significant amount of time in the extreme positions. This work investigated the change in delivered dose with jaws in the extreme positions, therefore overall changes in dose due to offset jaws are expected to be less for composite treatment deliveries. |
format | Online Article Text |
id | pubmed-8130229 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-81302292021-05-21 Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® Ferris, William S. Culberson, Wesley S. Smilowitz, Jennifer B. Bayouth, John E. J Appl Clin Med Phys Technical Notes PURPOSE: Radixact Synchrony corrects for target motion during treatment by adjusting the jaw and MLC positions in real time. As the jaws move off axis, Synchrony attempts to adjust for a loss in output due to the un‐flattened 6 MV beam by increasing the jaw aperture width. The purpose of this work was to assess the impact of the variable‐width aperture on delivered dose using measurements and simulations. METHODS: Longitudinal beam profile measurements were acquired using an Edge diode with static gantry. Jaw‐offset peak, width, and integral factors were calculated for profiles with the jaws in the extreme positions using both variable‐width (Synchrony) and fixed‐width apertures. Treatment plans with target motion and compensation were compared to planned doses to study the impact of the variable aperture on volumetric dose. RESULTS: The jaw offset peak factor (JOPF) for the Synchrony jaw settings were 0.964 and 0.983 for the 1.0‐ and 2.5‐cm jaw settings, respectively. These values decreased to 0.925 and 0.982 for the fixed‐width settings, indicating that the peak value of the profile would decrease by 7.5% compared to centered if the aperture width was held constant. The IMRT dose distributions reveal similar results, where gamma pass rates are above tolerance for the Synchrony jaw settings but fall significantly for the fixed‐width 1‐cm jaws. CONCLUSIONS: The variable‐width behavior of Synchrony jaws provides a larger output correction for the 1‐cm jaw setting. Without the variable‐aperture correction, plans with the 1‐cm jaw setting would underdose the target if the jaws spend a significant amount of time in the extreme positions. This work investigated the change in delivered dose with jaws in the extreme positions, therefore overall changes in dose due to offset jaws are expected to be less for composite treatment deliveries. John Wiley and Sons Inc. 2021-03-29 /pmc/articles/PMC8130229/ /pubmed/33779041 http://dx.doi.org/10.1002/acm2.13234 Text en © 2021 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technical Notes Ferris, William S. Culberson, Wesley S. Smilowitz, Jennifer B. Bayouth, John E. Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title | Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title_full | Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title_fullStr | Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title_full_unstemmed | Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title_short | Effects of variable‐width jaw motion on beam characteristics for Radixact Synchrony® |
title_sort | effects of variable‐width jaw motion on beam characteristics for radixact synchrony® |
topic | Technical Notes |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130229/ https://www.ncbi.nlm.nih.gov/pubmed/33779041 http://dx.doi.org/10.1002/acm2.13234 |
work_keys_str_mv | AT ferriswilliams effectsofvariablewidthjawmotiononbeamcharacteristicsforradixactsynchrony AT culbersonwesleys effectsofvariablewidthjawmotiononbeamcharacteristicsforradixactsynchrony AT smilowitzjenniferb effectsofvariablewidthjawmotiononbeamcharacteristicsforradixactsynchrony AT bayouthjohne effectsofvariablewidthjawmotiononbeamcharacteristicsforradixactsynchrony |