Cargando…

Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size

PURPOSE: Incorporating (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET/CT) for gross tumor volume (GTV) delineation is challenging due to varying tumor edge based on the set threshold of the standardized uptake value (SUV). This study aims to determine an opt...

Descripción completa

Detalles Bibliográficos
Autores principales: Tibdewal, Anil, Patil, Mangesh, Misra, Shagun, Purandare, Nilendu, Rangarajan, Venkatesh, Mummudi, Naveen, Karimundackal, George, Jiwnani, Sabita, Agarwal, Jaiprakash
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130683/
https://www.ncbi.nlm.nih.gov/pubmed/34040289
http://dx.doi.org/10.4103/ijnm.IJNM_134_20
_version_ 1783694571096506368
author Tibdewal, Anil
Patil, Mangesh
Misra, Shagun
Purandare, Nilendu
Rangarajan, Venkatesh
Mummudi, Naveen
Karimundackal, George
Jiwnani, Sabita
Agarwal, Jaiprakash
author_facet Tibdewal, Anil
Patil, Mangesh
Misra, Shagun
Purandare, Nilendu
Rangarajan, Venkatesh
Mummudi, Naveen
Karimundackal, George
Jiwnani, Sabita
Agarwal, Jaiprakash
author_sort Tibdewal, Anil
collection PubMed
description PURPOSE: Incorporating (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET/CT) for gross tumor volume (GTV) delineation is challenging due to varying tumor edge based on the set threshold of the standardized uptake value (SUV). This study aims to determine an optimal SUV threshold that correlates best with the pathological tumor size. MATERIALS AND METHODS: From January 2013 to July 2014, 25 consecutive patients of operable nonsmall-cell lung cancer (NSCLC) who underwent staging(18)F-FDG-PET/CT before surgical resection were included in the test cohort and 12 patients in the validation cohort. GTVs were delineated on the staging PET/CT by automatic delineation using various percentage threshold of maximum SUV (SUVmax) and absolute SUV. The maximum pathological tumor diameter was then matched with the maximum auto-delineated tumor diameter with varying SUV thresholds. First-order linear regression and Bland–Altman plots were used to obtain an optimal SUV threshold for each patient. Three radiation oncologists with varying degrees of experiences also delineated GTVs with the visual aid of PET/CT to assess interobserver variation in delineation. RESULTS: In the test set, the mean optimal percentage threshold for GTV was SUVmax of 35.6%±18.6% and absolute SUV of 4.35 ± 1.7. In the validation set, the mean optimal percentage threshold SUV and absolute SUV were 36.9 ± 16.9 and 4.1 ± 1.6, respectively. After a combined analysis of all 37 patients, the mean optimal threshold was 36% ± 17.9% and 4.27 ± 1.7, respectively. Using Bland–Altman plots, auto-contouring with 40% SUVmax and SUV 4 was in greater agreement with the pathological tumor diameter. CONCLUSION: Automatic GTV delineation on PETCT in NSCLC with percentage threshold SUV of 40% and absolute SUV of 4 correlated best with pathological tumor size. Auto-contouring using these thresholds will increase the precision of radiotherapy contouring of GTV and will save time.
format Online
Article
Text
id pubmed-8130683
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81306832021-05-25 Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size Tibdewal, Anil Patil, Mangesh Misra, Shagun Purandare, Nilendu Rangarajan, Venkatesh Mummudi, Naveen Karimundackal, George Jiwnani, Sabita Agarwal, Jaiprakash Indian J Nucl Med Original Article PURPOSE: Incorporating (18)F-fluorodeoxyglucose positron emission tomography-computed tomography ((18)F-FDG-PET/CT) for gross tumor volume (GTV) delineation is challenging due to varying tumor edge based on the set threshold of the standardized uptake value (SUV). This study aims to determine an optimal SUV threshold that correlates best with the pathological tumor size. MATERIALS AND METHODS: From January 2013 to July 2014, 25 consecutive patients of operable nonsmall-cell lung cancer (NSCLC) who underwent staging(18)F-FDG-PET/CT before surgical resection were included in the test cohort and 12 patients in the validation cohort. GTVs were delineated on the staging PET/CT by automatic delineation using various percentage threshold of maximum SUV (SUVmax) and absolute SUV. The maximum pathological tumor diameter was then matched with the maximum auto-delineated tumor diameter with varying SUV thresholds. First-order linear regression and Bland–Altman plots were used to obtain an optimal SUV threshold for each patient. Three radiation oncologists with varying degrees of experiences also delineated GTVs with the visual aid of PET/CT to assess interobserver variation in delineation. RESULTS: In the test set, the mean optimal percentage threshold for GTV was SUVmax of 35.6%±18.6% and absolute SUV of 4.35 ± 1.7. In the validation set, the mean optimal percentage threshold SUV and absolute SUV were 36.9 ± 16.9 and 4.1 ± 1.6, respectively. After a combined analysis of all 37 patients, the mean optimal threshold was 36% ± 17.9% and 4.27 ± 1.7, respectively. Using Bland–Altman plots, auto-contouring with 40% SUVmax and SUV 4 was in greater agreement with the pathological tumor diameter. CONCLUSION: Automatic GTV delineation on PETCT in NSCLC with percentage threshold SUV of 40% and absolute SUV of 4 correlated best with pathological tumor size. Auto-contouring using these thresholds will increase the precision of radiotherapy contouring of GTV and will save time. Wolters Kluwer - Medknow 2021 2021-03-04 /pmc/articles/PMC8130683/ /pubmed/34040289 http://dx.doi.org/10.4103/ijnm.IJNM_134_20 Text en Copyright: © 2021 Indian Journal of Nuclear Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Tibdewal, Anil
Patil, Mangesh
Misra, Shagun
Purandare, Nilendu
Rangarajan, Venkatesh
Mummudi, Naveen
Karimundackal, George
Jiwnani, Sabita
Agarwal, Jaiprakash
Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title_full Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title_fullStr Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title_full_unstemmed Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title_short Optimal Standardized Uptake Value Threshold for Auto contouring of Gross Tumor Volume using Positron Emission Tomography/Computed Tomography in Patients with Operable Nonsmall-Cell Lung Cancer: Comparison with Pathological Tumor Size
title_sort optimal standardized uptake value threshold for auto contouring of gross tumor volume using positron emission tomography/computed tomography in patients with operable nonsmall-cell lung cancer: comparison with pathological tumor size
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130683/
https://www.ncbi.nlm.nih.gov/pubmed/34040289
http://dx.doi.org/10.4103/ijnm.IJNM_134_20
work_keys_str_mv AT tibdewalanil optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT patilmangesh optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT misrashagun optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT purandarenilendu optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT rangarajanvenkatesh optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT mummudinaveen optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT karimundackalgeorge optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT jiwnanisabita optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize
AT agarwaljaiprakash optimalstandardizeduptakevaluethresholdforautocontouringofgrosstumorvolumeusingpositronemissiontomographycomputedtomographyinpatientswithoperablenonsmallcelllungcancercomparisonwithpathologicaltumorsize