Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It

PURPOSE OF STUDY: The purpose of the study was to evaluate the effect of patient characteristics and equipment-related factors on the computed tomography (CT) dose received by patients from positron emission tomography-CT (PET-CT) using system-generated dose-length product (DLP) values and also to c...

Descripción completa

Detalles Bibliográficos
Autores principales: Kumar, Vikrant, Tayal, Sachin, Ali, Abbas, Gandhi, Arun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130704/
https://www.ncbi.nlm.nih.gov/pubmed/34040293
http://dx.doi.org/10.4103/ijnm.IJNM_112_20
_version_ 1783694576410689536
author Kumar, Vikrant
Tayal, Sachin
Ali, Abbas
Gandhi, Arun
author_facet Kumar, Vikrant
Tayal, Sachin
Ali, Abbas
Gandhi, Arun
author_sort Kumar, Vikrant
collection PubMed
description PURPOSE OF STUDY: The purpose of the study was to evaluate the effect of patient characteristics and equipment-related factors on the computed tomography (CT) dose received by patients from positron emission tomography-CT (PET-CT) using system-generated dose-length product (DLP) values and also to check the effective dose (ED) received from various CT protocols at our institute. MATERIALS AND METHODS: This retrospective study included 78 adult patients who underwent F-18 fluorodeoxyglucose whole-body PET-CT and were divided into three groups based on the area of primary cancerous lesion. In Group A, we had 44 patients who underwent PET-CT (head-and-neck protocol), in Group B, we had 24 patients who underwent PET-CT (whole body with brain protocol), and in Group C, we had 10 patients who underwent PET-CT (pelvis protocol). All of the patients under the study are of South Asian ethnicity. A majority of patients 53.85% were males and remaining 46.15% were females. The product of conversion factor (k-coefficient), as described in “American Association of Physicists in Medicine Report No. 96” and DLP value generated by the scanner, was used to calculate the ED. Moreover, we also performed regression analysis to check relation between body weight, height, scan range, tube current, Volume computed tomography dose index (CTDIvol), DLP, and ED. RESULTS: The regression analysis shows that scan range, patient height, weight, tube current, and DLP were significantly correlated with ED (P < 0.05 for all). Moreover, the DLP and conversion factor method estimated the ED from various groups. Patients under Group A (head-and-neck protocol), Group B (whole body with brain protocol), Group C (pelvis protocol) received an average ED of 22.45 mSv, 22.40 mSv, and 21.24 mSv, respectively. CONCLUSION: ED from CT component of PET-CT can be assessed as the product of scanner-generated DLP and conversion factor for selected range. Moreover, body weight, scan range, and tube current had an independent significant effect on ED received from CT.
format Online
Article
Text
id pubmed-8130704
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-81307042021-05-25 Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It Kumar, Vikrant Tayal, Sachin Ali, Abbas Gandhi, Arun Indian J Nucl Med Original Article PURPOSE OF STUDY: The purpose of the study was to evaluate the effect of patient characteristics and equipment-related factors on the computed tomography (CT) dose received by patients from positron emission tomography-CT (PET-CT) using system-generated dose-length product (DLP) values and also to check the effective dose (ED) received from various CT protocols at our institute. MATERIALS AND METHODS: This retrospective study included 78 adult patients who underwent F-18 fluorodeoxyglucose whole-body PET-CT and were divided into three groups based on the area of primary cancerous lesion. In Group A, we had 44 patients who underwent PET-CT (head-and-neck protocol), in Group B, we had 24 patients who underwent PET-CT (whole body with brain protocol), and in Group C, we had 10 patients who underwent PET-CT (pelvis protocol). All of the patients under the study are of South Asian ethnicity. A majority of patients 53.85% were males and remaining 46.15% were females. The product of conversion factor (k-coefficient), as described in “American Association of Physicists in Medicine Report No. 96” and DLP value generated by the scanner, was used to calculate the ED. Moreover, we also performed regression analysis to check relation between body weight, height, scan range, tube current, Volume computed tomography dose index (CTDIvol), DLP, and ED. RESULTS: The regression analysis shows that scan range, patient height, weight, tube current, and DLP were significantly correlated with ED (P < 0.05 for all). Moreover, the DLP and conversion factor method estimated the ED from various groups. Patients under Group A (head-and-neck protocol), Group B (whole body with brain protocol), Group C (pelvis protocol) received an average ED of 22.45 mSv, 22.40 mSv, and 21.24 mSv, respectively. CONCLUSION: ED from CT component of PET-CT can be assessed as the product of scanner-generated DLP and conversion factor for selected range. Moreover, body weight, scan range, and tube current had an independent significant effect on ED received from CT. Wolters Kluwer - Medknow 2021 2021-03-04 /pmc/articles/PMC8130704/ /pubmed/34040293 http://dx.doi.org/10.4103/ijnm.IJNM_112_20 Text en Copyright: © 2021 Indian Journal of Nuclear Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Kumar, Vikrant
Tayal, Sachin
Ali, Abbas
Gandhi, Arun
Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title_full Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title_fullStr Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title_full_unstemmed Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title_short Assessment of Effective Dose Received in Various Computed Tomography Protocols and Factors Affecting It
title_sort assessment of effective dose received in various computed tomography protocols and factors affecting it
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8130704/
https://www.ncbi.nlm.nih.gov/pubmed/34040293
http://dx.doi.org/10.4103/ijnm.IJNM_112_20
work_keys_str_mv AT kumarvikrant assessmentofeffectivedosereceivedinvariouscomputedtomographyprotocolsandfactorsaffectingit
AT tayalsachin assessmentofeffectivedosereceivedinvariouscomputedtomographyprotocolsandfactorsaffectingit
AT aliabbas assessmentofeffectivedosereceivedinvariouscomputedtomographyprotocolsandfactorsaffectingit
AT gandhiarun assessmentofeffectivedosereceivedinvariouscomputedtomographyprotocolsandfactorsaffectingit