Cargando…
Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate
Although mineral trioxide aggregates (MTA) have been adopted as an endodontic sealer because of excellent sealing effect and bioactive property and been modified with improvement of its characteristics, the developed MTA sealers have not yet satisfied all the ideal requirements of endodontic sealers...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131355/ https://www.ncbi.nlm.nih.gov/pubmed/34006881 http://dx.doi.org/10.1038/s41598-021-90033-9 |
_version_ | 1783694691306307584 |
---|---|
author | Kim, Hyun-Jung Jang, Ji-Hyun Kim, Sun-Young |
author_facet | Kim, Hyun-Jung Jang, Ji-Hyun Kim, Sun-Young |
author_sort | Kim, Hyun-Jung |
collection | PubMed |
description | Although mineral trioxide aggregates (MTA) have been adopted as an endodontic sealer because of excellent sealing effect and bioactive property and been modified with improvement of its characteristics, the developed MTA sealers have not yet satisfied all the ideal requirements of endodontic sealers. The aim of this study was to assess the characteristics of elastin-like polypeptide (ELP)-incorporated MTA for use as an endodontic sealer and compare them with those of commercial MTA sealers. Two commercial MTA sealers and three experimental ELP-incorporated MTA sealers with 0.3, 0.4, and 0.5 liquid/powder (L/P) ratio for 10 wt% ELP liquid were evaluated. The push-out bond strength, flow rate, sealer penetrability and wash-out resistance were tested and the sealer-dentin interface was observed using a scanning electron microscope (SEM). Our study revealed the ELP-incorporated MTA sealer, especially in 0.4 L/P ratio, exhibited the higher push-out bond strength and flow rate (P < 0.05), and equal or superior sealer penetration and remarkable wash-out resistance compared to commercial MTA sealers. The groups of ELP-based experimental sealers also exhibited more intimate contact with dentin compared to the commercial MTA sealers. Our research will suggest the possible adoption of the ELP-incorporated MTA as endodontic sealer for clinical use. |
format | Online Article Text |
id | pubmed-8131355 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-81313552021-05-19 Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate Kim, Hyun-Jung Jang, Ji-Hyun Kim, Sun-Young Sci Rep Article Although mineral trioxide aggregates (MTA) have been adopted as an endodontic sealer because of excellent sealing effect and bioactive property and been modified with improvement of its characteristics, the developed MTA sealers have not yet satisfied all the ideal requirements of endodontic sealers. The aim of this study was to assess the characteristics of elastin-like polypeptide (ELP)-incorporated MTA for use as an endodontic sealer and compare them with those of commercial MTA sealers. Two commercial MTA sealers and three experimental ELP-incorporated MTA sealers with 0.3, 0.4, and 0.5 liquid/powder (L/P) ratio for 10 wt% ELP liquid were evaluated. The push-out bond strength, flow rate, sealer penetrability and wash-out resistance were tested and the sealer-dentin interface was observed using a scanning electron microscope (SEM). Our study revealed the ELP-incorporated MTA sealer, especially in 0.4 L/P ratio, exhibited the higher push-out bond strength and flow rate (P < 0.05), and equal or superior sealer penetration and remarkable wash-out resistance compared to commercial MTA sealers. The groups of ELP-based experimental sealers also exhibited more intimate contact with dentin compared to the commercial MTA sealers. Our research will suggest the possible adoption of the ELP-incorporated MTA as endodontic sealer for clinical use. Nature Publishing Group UK 2021-05-18 /pmc/articles/PMC8131355/ /pubmed/34006881 http://dx.doi.org/10.1038/s41598-021-90033-9 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Kim, Hyun-Jung Jang, Ji-Hyun Kim, Sun-Young Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title | Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title_full | Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title_fullStr | Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title_full_unstemmed | Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title_short | Investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
title_sort | investigation of characteristics as endodontic sealer of novel experimental elastin-like polypeptide-based mineral trioxide aggregate |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8131355/ https://www.ncbi.nlm.nih.gov/pubmed/34006881 http://dx.doi.org/10.1038/s41598-021-90033-9 |
work_keys_str_mv | AT kimhyunjung investigationofcharacteristicsasendodonticsealerofnovelexperimentalelastinlikepolypeptidebasedmineraltrioxideaggregate AT jangjihyun investigationofcharacteristicsasendodonticsealerofnovelexperimentalelastinlikepolypeptidebasedmineraltrioxideaggregate AT kimsunyoung investigationofcharacteristicsasendodonticsealerofnovelexperimentalelastinlikepolypeptidebasedmineraltrioxideaggregate |