Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia

PURPOSE: To assess en face ellipsoid zone (EZ) maps of remaining retinal structure as outcome measures for the future clinical research in patients with choroideremia. METHODS: Twenty eyes from 12 patients with a confirmed genetic diagnosis of choroideremia were included retrospectively from a singl...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhai, Yi, Oke, Sarah, MacDonald, Ian M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8132016/
https://www.ncbi.nlm.nih.gov/pubmed/34111265
http://dx.doi.org/10.1167/tvst.10.6.17
_version_ 1783694832274767872
author Zhai, Yi
Oke, Sarah
MacDonald, Ian M.
author_facet Zhai, Yi
Oke, Sarah
MacDonald, Ian M.
author_sort Zhai, Yi
collection PubMed
description PURPOSE: To assess en face ellipsoid zone (EZ) maps of remaining retinal structure as outcome measures for the future clinical research in patients with choroideremia. METHODS: Twenty eyes from 12 patients with a confirmed genetic diagnosis of choroideremia were included retrospectively from a single site. From spectral domain-optical coherence tomography volume scans, slabs including the EZ were manually segmented to create the en face EZ maps. The preserved EZ area was measured by two graders. Lengths of the EZ were recorded at 0°, 45°, 90°, and 135°. The intraclass correlation coefficients and Bland–Altman plots were used to show intergrader agreement. The Pearson correlation coefficient evaluated the correlation between length and area. A Bland–Altman plot compared en face EZ and the preserved fundus autofluorescence area. RESULTS: Measurements of EZ area by two graders showed excellent agreement with an intraclass correlation coefficient of 0.992 (95% confidence interval, 0.980–0.997). A Pearson correlation analysis showed that the existing marker for preserved photoreceptor (horizontal EZ length) was correlated with the area (r = 0.722). The average EZ length in four meridians showed a much better correlation with the EZ area (r = 0.929). The fundus autofluorescence area was found to be a mean of 0.45 ± 0.99 mm(2) greater than the EZ area. CONCLUSIONS: EZ area measurement provides excellent intergrader reliability, although the process is time consuming. We propose a less time-consuming alternative to estimate the EZ by using the average EZ band length in meridians. Our data also suggest that the loss of photoreceptor inner segments is an early change in choroideremia and may happen before the loss of the retinal pigment epithelium. TRANSLATIONAL RELEVANCE: En face EZ mapping is a potential tool for future clinical trials to quantify preserved photoreceptor structure in choroideremia.
format Online
Article
Text
id pubmed-8132016
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-81320162021-05-25 Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia Zhai, Yi Oke, Sarah MacDonald, Ian M. Transl Vis Sci Technol Article PURPOSE: To assess en face ellipsoid zone (EZ) maps of remaining retinal structure as outcome measures for the future clinical research in patients with choroideremia. METHODS: Twenty eyes from 12 patients with a confirmed genetic diagnosis of choroideremia were included retrospectively from a single site. From spectral domain-optical coherence tomography volume scans, slabs including the EZ were manually segmented to create the en face EZ maps. The preserved EZ area was measured by two graders. Lengths of the EZ were recorded at 0°, 45°, 90°, and 135°. The intraclass correlation coefficients and Bland–Altman plots were used to show intergrader agreement. The Pearson correlation coefficient evaluated the correlation between length and area. A Bland–Altman plot compared en face EZ and the preserved fundus autofluorescence area. RESULTS: Measurements of EZ area by two graders showed excellent agreement with an intraclass correlation coefficient of 0.992 (95% confidence interval, 0.980–0.997). A Pearson correlation analysis showed that the existing marker for preserved photoreceptor (horizontal EZ length) was correlated with the area (r = 0.722). The average EZ length in four meridians showed a much better correlation with the EZ area (r = 0.929). The fundus autofluorescence area was found to be a mean of 0.45 ± 0.99 mm(2) greater than the EZ area. CONCLUSIONS: EZ area measurement provides excellent intergrader reliability, although the process is time consuming. We propose a less time-consuming alternative to estimate the EZ by using the average EZ band length in meridians. Our data also suggest that the loss of photoreceptor inner segments is an early change in choroideremia and may happen before the loss of the retinal pigment epithelium. TRANSLATIONAL RELEVANCE: En face EZ mapping is a potential tool for future clinical trials to quantify preserved photoreceptor structure in choroideremia. The Association for Research in Vision and Ophthalmology 2021-05-12 /pmc/articles/PMC8132016/ /pubmed/34111265 http://dx.doi.org/10.1167/tvst.10.6.17 Text en Copyright 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Zhai, Yi
Oke, Sarah
MacDonald, Ian M.
Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title_full Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title_fullStr Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title_full_unstemmed Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title_short Validating Ellipsoid Zone Area Measurement With Multimodal Imaging in Choroideremia
title_sort validating ellipsoid zone area measurement with multimodal imaging in choroideremia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8132016/
https://www.ncbi.nlm.nih.gov/pubmed/34111265
http://dx.doi.org/10.1167/tvst.10.6.17
work_keys_str_mv AT zhaiyi validatingellipsoidzoneareameasurementwithmultimodalimaginginchoroideremia
AT okesarah validatingellipsoidzoneareameasurementwithmultimodalimaginginchoroideremia
AT macdonaldianm validatingellipsoidzoneareameasurementwithmultimodalimaginginchoroideremia