Cargando…

Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study

BACKGROUND: Postpartum hemorrhage (PPH) is a major obstetric complication, and the real-time measurement of blood loss is important in the management and treatment of PPH. We designed a new two-set liquid collection bag (TSLCB) for measuring postpartum blood loss in vaginal delivery. The aim of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Fang, Lu, Nanjia, Weng, Xiaofeng, Tian, Yanping, Sun, Shiwen, Li, Baohua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8133090/
https://www.ncbi.nlm.nih.gov/pubmed/34106652
http://dx.doi.org/10.1097/MD.0000000000025906
_version_ 1783695017832873984
author Wang, Fang
Lu, Nanjia
Weng, Xiaofeng
Tian, Yanping
Sun, Shiwen
Li, Baohua
author_facet Wang, Fang
Lu, Nanjia
Weng, Xiaofeng
Tian, Yanping
Sun, Shiwen
Li, Baohua
author_sort Wang, Fang
collection PubMed
description BACKGROUND: Postpartum hemorrhage (PPH) is a major obstetric complication, and the real-time measurement of blood loss is important in the management and treatment of PPH. We designed a new two-set liquid collection bag (TSLCB) for measuring postpartum blood loss in vaginal delivery. The aim of this study was to evaluate the effectiveness of the TSLCB in separating the blood from the amniotic fluid during vaginal delivery and in determining the accuracy of the measured postpartum blood loss. METHODS: A prospective, randomized, case control study was conducted in the Women's Hospital, Zhejiang University School of Medicine, from March 2018 to April 2018. Sixty single pregnant women with spontaneous labor at 37–41 weeks without maternal complications were randomly divided into the experimental and control groups. The TSLCB was used to evaluate separately the amount of blood and amniotic fluid. For the control group, visual estimation and traditional plastic blood-collecting consumables were used to estimate the amount of postpartum blood loss. The measured blood loss between the two groups was compared, and the association of the measured blood loss with various clinical lab indices and vital signs was investigated. RESULTS: The TSLCB (the experimental group) improved the detection of the measured blood loss compared with visual estimation and the traditional method (the control group) (P < .05). In the experimental group, correlation analysis showed that the measured blood loss at delivery and within 24 h of delivery was significantly associated with the decreased hemoglobin level, red blood cell count, and hematocrit level of patients (r = −0.574, −0.455, −0.437; r = 0.-595, −0.368, −0.374; P < .05). In the control group, only the measured blood loss within 24 h of delivery was associated with the decreased hemoglobin level (r = −0.395, P < .05). No blood transfusion and plasma expanders were required in the treatment of PPH for both groups. CONCLUSIONS: The TSLCB can be used to accurately measure the postpartum blood loss in vaginal delivery by medical personnel.
format Online
Article
Text
id pubmed-8133090
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-81330902021-05-24 Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study Wang, Fang Lu, Nanjia Weng, Xiaofeng Tian, Yanping Sun, Shiwen Li, Baohua Medicine (Baltimore) 5600 BACKGROUND: Postpartum hemorrhage (PPH) is a major obstetric complication, and the real-time measurement of blood loss is important in the management and treatment of PPH. We designed a new two-set liquid collection bag (TSLCB) for measuring postpartum blood loss in vaginal delivery. The aim of this study was to evaluate the effectiveness of the TSLCB in separating the blood from the amniotic fluid during vaginal delivery and in determining the accuracy of the measured postpartum blood loss. METHODS: A prospective, randomized, case control study was conducted in the Women's Hospital, Zhejiang University School of Medicine, from March 2018 to April 2018. Sixty single pregnant women with spontaneous labor at 37–41 weeks without maternal complications were randomly divided into the experimental and control groups. The TSLCB was used to evaluate separately the amount of blood and amniotic fluid. For the control group, visual estimation and traditional plastic blood-collecting consumables were used to estimate the amount of postpartum blood loss. The measured blood loss between the two groups was compared, and the association of the measured blood loss with various clinical lab indices and vital signs was investigated. RESULTS: The TSLCB (the experimental group) improved the detection of the measured blood loss compared with visual estimation and the traditional method (the control group) (P < .05). In the experimental group, correlation analysis showed that the measured blood loss at delivery and within 24 h of delivery was significantly associated with the decreased hemoglobin level, red blood cell count, and hematocrit level of patients (r = −0.574, −0.455, −0.437; r = 0.-595, −0.368, −0.374; P < .05). In the control group, only the measured blood loss within 24 h of delivery was associated with the decreased hemoglobin level (r = −0.395, P < .05). No blood transfusion and plasma expanders were required in the treatment of PPH for both groups. CONCLUSIONS: The TSLCB can be used to accurately measure the postpartum blood loss in vaginal delivery by medical personnel. Lippincott Williams & Wilkins 2021-05-14 /pmc/articles/PMC8133090/ /pubmed/34106652 http://dx.doi.org/10.1097/MD.0000000000025906 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle 5600
Wang, Fang
Lu, Nanjia
Weng, Xiaofeng
Tian, Yanping
Sun, Shiwen
Li, Baohua
Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title_full Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title_fullStr Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title_full_unstemmed Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title_short Measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: A prospective, randomized, case control study
title_sort measurement of postpartum blood loss using a new two-set liquid collection bag for vaginal delivery: a prospective, randomized, case control study
topic 5600
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8133090/
https://www.ncbi.nlm.nih.gov/pubmed/34106652
http://dx.doi.org/10.1097/MD.0000000000025906
work_keys_str_mv AT wangfang measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy
AT lunanjia measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy
AT wengxiaofeng measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy
AT tianyanping measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy
AT sunshiwen measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy
AT libaohua measurementofpostpartumbloodlossusinganewtwosetliquidcollectionbagforvaginaldeliveryaprospectiverandomizedcasecontrolstudy