Cargando…
Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial
BACKGROUND: Recurrent paroxysmal atrial fibrillation (AF) after catheter ablation is presumably caused by failure to achieve durable pulmonary vein isolation (PVI). The primary methods of PVI are radiofrequency catheter ablation (RF) and cryoballoon catheter ablation (CRYO), but these methods have n...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136462/ https://www.ncbi.nlm.nih.gov/pubmed/33835823 http://dx.doi.org/10.1161/CIRCEP.120.009573 |
_version_ | 1783695448558534656 |
---|---|
author | Sørensen, Samuel K. Johannessen, Arne Worck, René Hansen, Morten L. Hansen, Jim |
author_facet | Sørensen, Samuel K. Johannessen, Arne Worck, René Hansen, Morten L. Hansen, Jim |
author_sort | Sørensen, Samuel K. |
collection | PubMed |
description | BACKGROUND: Recurrent paroxysmal atrial fibrillation (AF) after catheter ablation is presumably caused by failure to achieve durable pulmonary vein isolation (PVI). The primary methods of PVI are radiofrequency catheter ablation (RF) and cryoballoon catheter ablation (CRYO), but these methods have not been directly compared with respect to PVI durability and the effect thereof on AF burden (% of time in AF). METHODS: Accordingly, we performed a randomized trial including 98 patients (68% male, 61 [55–67] years) with paroxysmal AF assigned 1:1 to PVI by contact-force sensing, irrigated radiofrequency catheter, or second-generation cryoballoon catheter. Implantable cardiac monitors were inserted ≥1 month before PVI for assessment of AF burden and recurrence, and all patients, irrespective of AF recurrence, underwent a second procedure 4 to 6 months after PVI to determine PVI durability. RESULTS: In the second procedure, 152 out of 199 (76%) pulmonary veins (PVs) were found durably isolated after RF and 161 out of 200 (81%) after CRYO (P=0.32), corresponding to durable isolation of all veins in 47% of patients in both groups (P=1.0). Median AF burden before PVI was 5.4% (interquartile range, 0.5%–13.0%) versus 4.0% (0.6%–18.1%), RF versus CRYO (P=0.71), and reduced to 0.0% (0.0%–0.1%) and 0.0% (0.0%–0.5%), respectively (P=0.58)—a reduction of 99.9% (92.9%–100.0%) and 99.3% (85.9%–100.0%; P=0.36). AF burden after PVI significantly correlated to the number of durably isolated PVs (P<0.01), but 9 out of 45 (20%) patients with durable isolation of all veins had recurrence of AF within 4 to 6 months after PVI (excluding a 3-month blanking period). CONCLUSIONS: PVI by RF and CRYO produce similar moderate to high PVI durability. Both treatments lead to marked reductions in AF burden, which is related to the number of durably isolated PVs. However, for one-fifth of paroxysmal AF patients, complete and durable PVI was not sufficient to prevent even short-term AF recurrence. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03805555. |
format | Online Article Text |
id | pubmed-8136462 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-81364622021-05-26 Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial Sørensen, Samuel K. Johannessen, Arne Worck, René Hansen, Morten L. Hansen, Jim Circ Arrhythm Electrophysiol Original Articles BACKGROUND: Recurrent paroxysmal atrial fibrillation (AF) after catheter ablation is presumably caused by failure to achieve durable pulmonary vein isolation (PVI). The primary methods of PVI are radiofrequency catheter ablation (RF) and cryoballoon catheter ablation (CRYO), but these methods have not been directly compared with respect to PVI durability and the effect thereof on AF burden (% of time in AF). METHODS: Accordingly, we performed a randomized trial including 98 patients (68% male, 61 [55–67] years) with paroxysmal AF assigned 1:1 to PVI by contact-force sensing, irrigated radiofrequency catheter, or second-generation cryoballoon catheter. Implantable cardiac monitors were inserted ≥1 month before PVI for assessment of AF burden and recurrence, and all patients, irrespective of AF recurrence, underwent a second procedure 4 to 6 months after PVI to determine PVI durability. RESULTS: In the second procedure, 152 out of 199 (76%) pulmonary veins (PVs) were found durably isolated after RF and 161 out of 200 (81%) after CRYO (P=0.32), corresponding to durable isolation of all veins in 47% of patients in both groups (P=1.0). Median AF burden before PVI was 5.4% (interquartile range, 0.5%–13.0%) versus 4.0% (0.6%–18.1%), RF versus CRYO (P=0.71), and reduced to 0.0% (0.0%–0.1%) and 0.0% (0.0%–0.5%), respectively (P=0.58)—a reduction of 99.9% (92.9%–100.0%) and 99.3% (85.9%–100.0%; P=0.36). AF burden after PVI significantly correlated to the number of durably isolated PVs (P<0.01), but 9 out of 45 (20%) patients with durable isolation of all veins had recurrence of AF within 4 to 6 months after PVI (excluding a 3-month blanking period). CONCLUSIONS: PVI by RF and CRYO produce similar moderate to high PVI durability. Both treatments lead to marked reductions in AF burden, which is related to the number of durably isolated PVs. However, for one-fifth of paroxysmal AF patients, complete and durable PVI was not sufficient to prevent even short-term AF recurrence. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03805555. Lippincott Williams & Wilkins 2021-04-09 /pmc/articles/PMC8136462/ /pubmed/33835823 http://dx.doi.org/10.1161/CIRCEP.120.009573 Text en © 2021 The Authors. https://creativecommons.org/licenses/by-nc-nd/4.0/Circulation: Arrhythmia and Electrophysiology is published on behalf of the American Heart Association, Inc., by Wolters Kluwer Health, Inc. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial-NoDerivs (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use, distribution, and reproduction in any medium, provided that the original work is properly cited, the use is noncommercial, and no modifications or adaptations are made. This article is made available via the PMC Open Access Subset for unrestricted re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the COVID-19 pandemic or until permissions are revoked in writing. Upon expiration of these permissions, PMC is granted a perpetual license to make this article available via PMC and Europe PMC, consistent with existing copyright protections. |
spellingShingle | Original Articles Sørensen, Samuel K. Johannessen, Arne Worck, René Hansen, Morten L. Hansen, Jim Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title | Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title_full | Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title_fullStr | Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title_full_unstemmed | Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title_short | Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial |
title_sort | radiofrequency versus cryoballoon catheter ablation for paroxysmal atrial fibrillation: durability of pulmonary vein isolation and effect on atrial fibrillation burden: the race-af randomized controlled trial |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136462/ https://www.ncbi.nlm.nih.gov/pubmed/33835823 http://dx.doi.org/10.1161/CIRCEP.120.009573 |
work_keys_str_mv | AT sørensensamuelk radiofrequencyversuscryoballooncatheterablationforparoxysmalatrialfibrillationdurabilityofpulmonaryveinisolationandeffectonatrialfibrillationburdentheraceafrandomizedcontrolledtrial AT johannessenarne radiofrequencyversuscryoballooncatheterablationforparoxysmalatrialfibrillationdurabilityofpulmonaryveinisolationandeffectonatrialfibrillationburdentheraceafrandomizedcontrolledtrial AT worckrene radiofrequencyversuscryoballooncatheterablationforparoxysmalatrialfibrillationdurabilityofpulmonaryveinisolationandeffectonatrialfibrillationburdentheraceafrandomizedcontrolledtrial AT hansenmortenl radiofrequencyversuscryoballooncatheterablationforparoxysmalatrialfibrillationdurabilityofpulmonaryveinisolationandeffectonatrialfibrillationburdentheraceafrandomizedcontrolledtrial AT hansenjim radiofrequencyversuscryoballooncatheterablationforparoxysmalatrialfibrillationdurabilityofpulmonaryveinisolationandeffectonatrialfibrillationburdentheraceafrandomizedcontrolledtrial |