Cargando…

Caliper navigation for craniotomy planning of convexity targets

INTRODUCTION: A technique to localize a radiological target on the head convexity fast and with acceptable precision is sufficient for surgeries of superficial intracranial lesions, and of help in the setting of emergency surgery, computer navigation breakdown, limited resources and education. We pr...

Descripción completa

Detalles Bibliográficos
Autores principales: Jägersberg, Max, Kosterhon, Michael, Ringel, Florian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136664/
https://www.ncbi.nlm.nih.gov/pubmed/34014940
http://dx.doi.org/10.1371/journal.pone.0251023
_version_ 1783695472478650368
author Jägersberg, Max
Kosterhon, Michael
Ringel, Florian
author_facet Jägersberg, Max
Kosterhon, Michael
Ringel, Florian
author_sort Jägersberg, Max
collection PubMed
description INTRODUCTION: A technique to localize a radiological target on the head convexity fast and with acceptable precision is sufficient for surgeries of superficial intracranial lesions, and of help in the setting of emergency surgery, computer navigation breakdown, limited resources and education. We present a caliper technique based on fundamental geometry, with inexpensive and globally available tools (conventional CT or MRI image viewer, calculator, caliper). METHODS: The distances of the radiological target from two landmarks (nasion and porus acusticus externus) are assessed with an image viewer and Pythagoras’ theorem. The two distances are then marked around the landmarks onto the head of the patient with help of a caliper. The intersection defines the target. We tested the technique in a saw bone skull model and afterwards in the operating room. Convexity targets were localized with the caliper navigation technique and then with computer navigation as ground truth. RESULTS: In the saw bone model, the mean offset between the caliper navigated target and the real target was 2.9 ± 2.8 mm, 95% CI (1.6 mm; 4.2 mm). The mean offset between computer navigated target and real target was 1.6 ± 0.9 mm, 95% CI (1.2 mm; 2 mm) (ns). In 15 patients undergoing navigated cranial procedures, 100 targets were assessed in reference to computer navigation. The mean offset of the caliper navigation was 11 ± 5.2 mm, 95% CI (9.9 mm; 12 mm). CONCLUSION: This is a low-tech approach for translation of a radiological target to the patient’s head in short time and with globally available inexpensive tools, with satisfying precision for many procedures.
format Online
Article
Text
id pubmed-8136664
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-81366642021-06-02 Caliper navigation for craniotomy planning of convexity targets Jägersberg, Max Kosterhon, Michael Ringel, Florian PLoS One Research Article INTRODUCTION: A technique to localize a radiological target on the head convexity fast and with acceptable precision is sufficient for surgeries of superficial intracranial lesions, and of help in the setting of emergency surgery, computer navigation breakdown, limited resources and education. We present a caliper technique based on fundamental geometry, with inexpensive and globally available tools (conventional CT or MRI image viewer, calculator, caliper). METHODS: The distances of the radiological target from two landmarks (nasion and porus acusticus externus) are assessed with an image viewer and Pythagoras’ theorem. The two distances are then marked around the landmarks onto the head of the patient with help of a caliper. The intersection defines the target. We tested the technique in a saw bone skull model and afterwards in the operating room. Convexity targets were localized with the caliper navigation technique and then with computer navigation as ground truth. RESULTS: In the saw bone model, the mean offset between the caliper navigated target and the real target was 2.9 ± 2.8 mm, 95% CI (1.6 mm; 4.2 mm). The mean offset between computer navigated target and real target was 1.6 ± 0.9 mm, 95% CI (1.2 mm; 2 mm) (ns). In 15 patients undergoing navigated cranial procedures, 100 targets were assessed in reference to computer navigation. The mean offset of the caliper navigation was 11 ± 5.2 mm, 95% CI (9.9 mm; 12 mm). CONCLUSION: This is a low-tech approach for translation of a radiological target to the patient’s head in short time and with globally available inexpensive tools, with satisfying precision for many procedures. Public Library of Science 2021-05-20 /pmc/articles/PMC8136664/ /pubmed/34014940 http://dx.doi.org/10.1371/journal.pone.0251023 Text en © 2021 Jägersberg et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Jägersberg, Max
Kosterhon, Michael
Ringel, Florian
Caliper navigation for craniotomy planning of convexity targets
title Caliper navigation for craniotomy planning of convexity targets
title_full Caliper navigation for craniotomy planning of convexity targets
title_fullStr Caliper navigation for craniotomy planning of convexity targets
title_full_unstemmed Caliper navigation for craniotomy planning of convexity targets
title_short Caliper navigation for craniotomy planning of convexity targets
title_sort caliper navigation for craniotomy planning of convexity targets
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8136664/
https://www.ncbi.nlm.nih.gov/pubmed/34014940
http://dx.doi.org/10.1371/journal.pone.0251023
work_keys_str_mv AT jagersbergmax calipernavigationforcraniotomyplanningofconvexitytargets
AT kosterhonmichael calipernavigationforcraniotomyplanningofconvexitytargets
AT ringelflorian calipernavigationforcraniotomyplanningofconvexitytargets