Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus
PURPOSE: To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. METHODS: Prospective case series at a university hospital tertiary center. Axial lengt...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8139453/ https://www.ncbi.nlm.nih.gov/pubmed/34019547 http://dx.doi.org/10.1371/journal.pone.0248659 |
_version_ | 1783696010918232064 |
---|---|
author | Li, Ye Gokul, Akilesh McGhee, Charles Ziaei, Mohammed |
author_facet | Li, Ye Gokul, Akilesh McGhee, Charles Ziaei, Mohammed |
author_sort | Li, Ye |
collection | PubMed |
description | PURPOSE: To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. METHODS: Prospective case series at a university hospital tertiary center. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and thinnest corneal thickness (TCT) were measured using both devices in patients with keratoconus. Three groups were analyzed: eyes with no prior crosslinking or contact lens wear (Group A), eyes with prior crosslinking (Group B), and eyes with prior contact lens wear (Group C). Repeatability and agreement of measurements were analyzed. RESULTS: The study comprised of 214 eyes of 157 subjects. In Group A (n = 95 eyes), Group B (n = 86 eyes), and Group C (n = 33 eyes), intraclass correlation coefficient (ICC) was higher than 0.90 for all examined parameters, except for ACD readings in Group A with the REVO-NX (ICC = 0.83). Differences in ACD, TCT, and CCT were significantly different between the two devices for Groups A, B and C (p<0.05). AL measurements differed significantly in Groups A and B (p<0.05) but not in Group C (p = 0.18). Repeatability did not vary significantly between Groups A, B, or C in any parameter with both devices (p>0.05). There was poor agreement between the two devices across all parameters (p<0.05). CONCLUSIONS: Both devices demonstrated good repeatability but poor agreement across AL, ACD, CCT and TCT measurements. There was no significant difference in repeatability in virgin eyes compared to eyes with prior crosslinking or contact lens wear, however, the interchangeable use of the two devices is not recommended. |
format | Online Article Text |
id | pubmed-8139453 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-81394532021-06-02 Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus Li, Ye Gokul, Akilesh McGhee, Charles Ziaei, Mohammed PLoS One Research Article PURPOSE: To compare the repeatability and agreement in biometric measurements using Spectral Domain Anterior Segment OCT (AS-OCT, REVO-NX, Optopol) and Scheimpflug tomography (Pentacam-AXL, Oculus) in keratoconus. METHODS: Prospective case series at a university hospital tertiary center. Axial length (AL), anterior chamber depth (ACD), central corneal thickness (CCT), and thinnest corneal thickness (TCT) were measured using both devices in patients with keratoconus. Three groups were analyzed: eyes with no prior crosslinking or contact lens wear (Group A), eyes with prior crosslinking (Group B), and eyes with prior contact lens wear (Group C). Repeatability and agreement of measurements were analyzed. RESULTS: The study comprised of 214 eyes of 157 subjects. In Group A (n = 95 eyes), Group B (n = 86 eyes), and Group C (n = 33 eyes), intraclass correlation coefficient (ICC) was higher than 0.90 for all examined parameters, except for ACD readings in Group A with the REVO-NX (ICC = 0.83). Differences in ACD, TCT, and CCT were significantly different between the two devices for Groups A, B and C (p<0.05). AL measurements differed significantly in Groups A and B (p<0.05) but not in Group C (p = 0.18). Repeatability did not vary significantly between Groups A, B, or C in any parameter with both devices (p>0.05). There was poor agreement between the two devices across all parameters (p<0.05). CONCLUSIONS: Both devices demonstrated good repeatability but poor agreement across AL, ACD, CCT and TCT measurements. There was no significant difference in repeatability in virgin eyes compared to eyes with prior crosslinking or contact lens wear, however, the interchangeable use of the two devices is not recommended. Public Library of Science 2021-05-21 /pmc/articles/PMC8139453/ /pubmed/34019547 http://dx.doi.org/10.1371/journal.pone.0248659 Text en © 2021 Li et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Li, Ye Gokul, Akilesh McGhee, Charles Ziaei, Mohammed Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title | Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title_full | Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title_fullStr | Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title_full_unstemmed | Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title_short | Repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and Scheimpflug tomography in keratoconus |
title_sort | repeatability and agreement of biometric measurements using spectral domain anterior segment optical coherence tomography and scheimpflug tomography in keratoconus |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8139453/ https://www.ncbi.nlm.nih.gov/pubmed/34019547 http://dx.doi.org/10.1371/journal.pone.0248659 |
work_keys_str_mv | AT liye repeatabilityandagreementofbiometricmeasurementsusingspectraldomainanteriorsegmentopticalcoherencetomographyandscheimpflugtomographyinkeratoconus AT gokulakilesh repeatabilityandagreementofbiometricmeasurementsusingspectraldomainanteriorsegmentopticalcoherencetomographyandscheimpflugtomographyinkeratoconus AT mcgheecharles repeatabilityandagreementofbiometricmeasurementsusingspectraldomainanteriorsegmentopticalcoherencetomographyandscheimpflugtomographyinkeratoconus AT ziaeimohammed repeatabilityandagreementofbiometricmeasurementsusingspectraldomainanteriorsegmentopticalcoherencetomographyandscheimpflugtomographyinkeratoconus |