Cargando…

Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance

BACKGROUND: Although the incidence of positive resection margins in breast-conserving surgery has decreased, both incomplete resection and unnecessary large resections still occur. This is especially the case in the surgical treatment of ductal carcinoma in situ (DCIS). Diffuse reflectance spectrosc...

Descripción completa

Detalles Bibliográficos
Autores principales: de Boer, Lisanne L., Kho, Esther, Van de Vijver, Koen K., Vranken Peeters, Marie-Jeanne T. F. D., van Duijnhoven, Frederieke, Hendriks, Benno H. W., Sterenborg, Henricus J. C. M., Ruers, Theo J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8141169/
https://www.ncbi.nlm.nih.gov/pubmed/34022928
http://dx.doi.org/10.1186/s13058-021-01436-5
_version_ 1783696311257661440
author de Boer, Lisanne L.
Kho, Esther
Van de Vijver, Koen K.
Vranken Peeters, Marie-Jeanne T. F. D.
van Duijnhoven, Frederieke
Hendriks, Benno H. W.
Sterenborg, Henricus J. C. M.
Ruers, Theo J. M.
author_facet de Boer, Lisanne L.
Kho, Esther
Van de Vijver, Koen K.
Vranken Peeters, Marie-Jeanne T. F. D.
van Duijnhoven, Frederieke
Hendriks, Benno H. W.
Sterenborg, Henricus J. C. M.
Ruers, Theo J. M.
author_sort de Boer, Lisanne L.
collection PubMed
description BACKGROUND: Although the incidence of positive resection margins in breast-conserving surgery has decreased, both incomplete resection and unnecessary large resections still occur. This is especially the case in the surgical treatment of ductal carcinoma in situ (DCIS). Diffuse reflectance spectroscopy (DRS), an optical technology based on light tissue interactions, can potentially characterize tissue during surgery thereby guiding the surgeon intraoperatively. DRS has shown to be able to discriminate pure healthy breast tissue from pure invasive carcinoma (IC) but limited research has been done on (1) the actual optical characteristics of DCIS and (2) the ability of DRS to characterize measurements that are a mixture of tissue types. METHODS: In this study, DRS spectra were acquired from 107 breast specimens from 107 patients with proven IC and/or DCIS (1488 measurement locations). With a generalized estimating equation model, the differences between the DRS spectra of locations with DCIS and IC and only healthy tissue were compared to see if there were significant differences between these spectra. Subsequently, different classification models were developed to be able to predict if the DRS spectrum of a measurement location represented a measurement location with “healthy” or “malignant” tissue. In the development and testing of the models, different definitions for “healthy” and “malignant” were used. This allowed varying the level of homogeneity in the train and test data. RESULTS: It was found that the optical characteristics of IC and DCIS were similar. Regarding the classification of tissue with a mixture of tissue types, it was found that using mixed measurement locations in the development of the classification models did not tremendously improve the accuracy of the classification of other measurement locations with a mixture of tissue types. The evaluated classification models were able to classify measurement locations with > 5% malignant cells with a Matthews correlation coefficient of 0.41 or 0.40. Some models showed better sensitivity whereas others had better specificity. CONCLUSION: The results suggest that DRS has the potential to detect malignant tissue, including DCIS, in healthy breast tissue and could thus be helpful for surgical guidance. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13058-021-01436-5.
format Online
Article
Text
id pubmed-8141169
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-81411692021-05-25 Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance de Boer, Lisanne L. Kho, Esther Van de Vijver, Koen K. Vranken Peeters, Marie-Jeanne T. F. D. van Duijnhoven, Frederieke Hendriks, Benno H. W. Sterenborg, Henricus J. C. M. Ruers, Theo J. M. Breast Cancer Res Research Article BACKGROUND: Although the incidence of positive resection margins in breast-conserving surgery has decreased, both incomplete resection and unnecessary large resections still occur. This is especially the case in the surgical treatment of ductal carcinoma in situ (DCIS). Diffuse reflectance spectroscopy (DRS), an optical technology based on light tissue interactions, can potentially characterize tissue during surgery thereby guiding the surgeon intraoperatively. DRS has shown to be able to discriminate pure healthy breast tissue from pure invasive carcinoma (IC) but limited research has been done on (1) the actual optical characteristics of DCIS and (2) the ability of DRS to characterize measurements that are a mixture of tissue types. METHODS: In this study, DRS spectra were acquired from 107 breast specimens from 107 patients with proven IC and/or DCIS (1488 measurement locations). With a generalized estimating equation model, the differences between the DRS spectra of locations with DCIS and IC and only healthy tissue were compared to see if there were significant differences between these spectra. Subsequently, different classification models were developed to be able to predict if the DRS spectrum of a measurement location represented a measurement location with “healthy” or “malignant” tissue. In the development and testing of the models, different definitions for “healthy” and “malignant” were used. This allowed varying the level of homogeneity in the train and test data. RESULTS: It was found that the optical characteristics of IC and DCIS were similar. Regarding the classification of tissue with a mixture of tissue types, it was found that using mixed measurement locations in the development of the classification models did not tremendously improve the accuracy of the classification of other measurement locations with a mixture of tissue types. The evaluated classification models were able to classify measurement locations with > 5% malignant cells with a Matthews correlation coefficient of 0.41 or 0.40. Some models showed better sensitivity whereas others had better specificity. CONCLUSION: The results suggest that DRS has the potential to detect malignant tissue, including DCIS, in healthy breast tissue and could thus be helpful for surgical guidance. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13058-021-01436-5. BioMed Central 2021-05-22 2021 /pmc/articles/PMC8141169/ /pubmed/34022928 http://dx.doi.org/10.1186/s13058-021-01436-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
de Boer, Lisanne L.
Kho, Esther
Van de Vijver, Koen K.
Vranken Peeters, Marie-Jeanne T. F. D.
van Duijnhoven, Frederieke
Hendriks, Benno H. W.
Sterenborg, Henricus J. C. M.
Ruers, Theo J. M.
Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title_full Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title_fullStr Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title_full_unstemmed Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title_short Optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
title_sort optical tissue measurements of invasive carcinoma and ductal carcinoma in situ for surgical guidance
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8141169/
https://www.ncbi.nlm.nih.gov/pubmed/34022928
http://dx.doi.org/10.1186/s13058-021-01436-5
work_keys_str_mv AT deboerlisannel opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT khoesther opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT vandevijverkoenk opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT vrankenpeetersmariejeannetfd opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT vanduijnhovenfrederieke opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT hendriksbennohw opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT sterenborghenricusjcm opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance
AT ruerstheojm opticaltissuemeasurementsofinvasivecarcinomaandductalcarcinomainsituforsurgicalguidance