Cargando…
Reliable detection of SARS-CoV-2 with patient-collected swabs and saline gargles: A three-headed comparison on multiple molecular platforms
With increasing demands for SARS-CoV-2 testing, as well as the shortages for testing supplies, collection devices, and trained healthcare workers (HCWs) to collect specimens, self-collection is an attractive prospect to reduce the need for HCWs and expenditure of personal protective equipment. Apart...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Authors. Published by Elsevier B.V.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8141269/ https://www.ncbi.nlm.nih.gov/pubmed/34029634 http://dx.doi.org/10.1016/j.jviromet.2021.114184 |
Sumario: | With increasing demands for SARS-CoV-2 testing, as well as the shortages for testing supplies, collection devices, and trained healthcare workers (HCWs) to collect specimens, self-collection is an attractive prospect to reduce the need for HCWs and expenditure of personal protective equipment. Apart from the traditional nasopharyngeal swab used for SARS-CoV-2 detection, alternative specimens have been validated such as a combined swabs of the oropharynx and anterior nares (OP/N), or throat samples using saline gargles. Both the alternative specimen types are amenable to self-collection. Objectives. This study aimed to compare the sensitivity of HCW-collected (OP/N) swabs, self-collected OP/N swabs, and self-collected saline gargles. Among 38 individuals previously testing positive for SARS-CoV-2 (or their close contacts), two self-collected specimen types (OP/N and saline gargles) were compared to HCW-collected OP/N swabs. SARS-CoV-2 testing was performed on three molecular assays: a laboratory-developed test (LDT), and two commercial assays on automated platforms: Cobas 6800 (Roche Diagnostics) and Panther (Hologic). The sensitivity of self-collected OP/N swabs was equivalent to healthcare worker (HCW)-collected OP/N swabs at 100.0 % [92.6%–100.0%] for all three molecular tests. The sensitivity of saline gargles was not significantly different than HCW-collected OP/N swabs, but varied slightly between instruments at 93.8 % [85.9%–93.8%] for the LDT, 96.8 % [88.6%–96.8%] for the Cobas assay, and 96.7 % [89.2%–96.9%] for the Panther assay. Overall, self-collection using OP/N swabs or saline gargles are reasonable alternatives to HCW-based collections for SARS-CoV-2 detection, and could facilitate broader surveillance strategies. |
---|