Cargando…

Clinical trial of carotid artery stenting using dual-layer CASPER stent for carotid endarterectomy in patients at high and normal risk in the Japanese population

BACKGROUND: The dual-layer nitinol CASPER stent was designed to prevent plaque prolapse into its strut and periprocedural stroke. OBJECTIVE: To conduct a clinical trial for government approval of the device in patients at either high or normal risk for carotid endarterectomy (CEA). METHODS: Eligible...

Descripción completa

Detalles Bibliográficos
Autores principales: Imamura, Hirotoshi, Sakai, Nobuyuki, Matsumoto, Yasushi, Yamagami, Hiroshi, Terada, Tomoaki, Fujinaka, Toshiyuki, Yoshimura, Shinichi, Sugiu, Kenji, Ishii, Akira, Matsumaru, Yuji, Izumi, Takashi, Oishi, Hidenori, Higashi, Toshio, Iihara, Koji, Kuwayama, Naoya, Ito, Yasushi, Nakamura, Masato, Hyodo, Akio, Ogasawara, Kuniaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8142440/
https://www.ncbi.nlm.nih.gov/pubmed/32934139
http://dx.doi.org/10.1136/neurintsurg-2020-016250
Descripción
Sumario:BACKGROUND: The dual-layer nitinol CASPER stent was designed to prevent plaque prolapse into its strut and periprocedural stroke. OBJECTIVE: To conduct a clinical trial for government approval of the device in patients at either high or normal risk for carotid endarterectomy (CEA). METHODS: Eligible patients had ≥50% symptomatic stenosis or ≥80% asymptomatic stenosis according to the North American Symptomatic Carotid Endarterectomy Trial methods (peak systolic velocity 130 and 230 cm/s on ultrasonography, respectively). The primary endpoint was the lack of major adverse events (MAEs), defined as death, stroke, and myocardial infarction within 30 days, and ipsilateral stroke within 1 year. The performance goal was set at 90.5%. MAE rates were also compared between the CEA high- and normal-risk groups. RESULTS: 140 carotid artery stenting procedures, including 40% of patients at high risk and 60% at normal risk for CEA, were performed in 13 institutes. MAEs occurred in two cases (one intraprocedural and one postprocedural stroke), and the MAE rate was 1.4%. The non-MAE rate was 98.6% according to Kaplan-Meier analysis, which was superior to the previously set performance goal. The deployment success, target lesion revascularization (TLR), in-stent restenosis, and cerebrovascular event rates were 99.3%, 2.4%, 8.5%, and 7.2%, respectively. The MAE rate in patients with normal CEA risk was 1.2%, which was similar to the high-risk CEA group, with no significant difference due to the small number of MAEs. CONCLUSIONS: The MAE rate following use of the CASPER stent was low (1.4%). The MAE, deployment success, TLR, in-stenosis, and cerebrovascular event rates were similar to those of previous reports.