Impurities in Drug Vials Intended for Intravitreal Medication

Sterility is an important prerequisite for minimizing the risk of severe vision loss due to endophthalmitis after intravitreal injections. We describe three cases series of incidents where an unclear contamination of the drug solution or syringe caused the injection process to stop and continue with...

Descripción completa

Detalles Bibliográficos
Autores principales: Pohl, Lisa, Strudel, Lisa, Dimopoulos, Spyridon, Ziemssen, Focke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8142807/
https://www.ncbi.nlm.nih.gov/pubmed/34055435
http://dx.doi.org/10.1155/2020/8824585
_version_ 1783696627749355520
author Pohl, Lisa
Strudel, Lisa
Dimopoulos, Spyridon
Ziemssen, Focke
author_facet Pohl, Lisa
Strudel, Lisa
Dimopoulos, Spyridon
Ziemssen, Focke
author_sort Pohl, Lisa
collection PubMed
description Sterility is an important prerequisite for minimizing the risk of severe vision loss due to endophthalmitis after intravitreal injections. We describe three cases series of incidents where an unclear contamination of the drug solution or syringe caused the injection process to stop and continue with a new preparation. During a period of 12 months with 30,502 intravitreal injections at a tertiary center, wherein 7,076 were of the drug Aflibercept drawn up from a glass vial, three cases of the critical incident reporting system relating to intravitreal injections were identified: (1) After a typical contact with the filter cannula, the glass of an Aflibercept vial was no longer intact. (2) In the course of another injection, there was a clear deposition of debris on the outer edge of the syringe when removing the attached filter cannula. (3) After inserting the syringe into the rubber top of the vial, a whitish particle of unclear origin was identified within the drug solution. Later, this contamination/particle was identified as part of the greyish rubber that was punched out with the cannula, according to the analyses of the material sent in and the manufacturer's investigations. Thus, even in busy clinics, visual inspection of the injection solution and materials used for impurities, preferably before and after pulling them out of a vial, must be an essential part of the injection process. Even when using ready-to-use prefilled syringes (PFS), vigilance must be kept high, knowing the risk of potential contamination.
format Online
Article
Text
id pubmed-8142807
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-81428072021-05-27 Impurities in Drug Vials Intended for Intravitreal Medication Pohl, Lisa Strudel, Lisa Dimopoulos, Spyridon Ziemssen, Focke Case Rep Ophthalmol Med Case Series Sterility is an important prerequisite for minimizing the risk of severe vision loss due to endophthalmitis after intravitreal injections. We describe three cases series of incidents where an unclear contamination of the drug solution or syringe caused the injection process to stop and continue with a new preparation. During a period of 12 months with 30,502 intravitreal injections at a tertiary center, wherein 7,076 were of the drug Aflibercept drawn up from a glass vial, three cases of the critical incident reporting system relating to intravitreal injections were identified: (1) After a typical contact with the filter cannula, the glass of an Aflibercept vial was no longer intact. (2) In the course of another injection, there was a clear deposition of debris on the outer edge of the syringe when removing the attached filter cannula. (3) After inserting the syringe into the rubber top of the vial, a whitish particle of unclear origin was identified within the drug solution. Later, this contamination/particle was identified as part of the greyish rubber that was punched out with the cannula, according to the analyses of the material sent in and the manufacturer's investigations. Thus, even in busy clinics, visual inspection of the injection solution and materials used for impurities, preferably before and after pulling them out of a vial, must be an essential part of the injection process. Even when using ready-to-use prefilled syringes (PFS), vigilance must be kept high, knowing the risk of potential contamination. Hindawi 2020-12-02 /pmc/articles/PMC8142807/ /pubmed/34055435 http://dx.doi.org/10.1155/2020/8824585 Text en Copyright © 2020 Lisa Pohl et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Series
Pohl, Lisa
Strudel, Lisa
Dimopoulos, Spyridon
Ziemssen, Focke
Impurities in Drug Vials Intended for Intravitreal Medication
title Impurities in Drug Vials Intended for Intravitreal Medication
title_full Impurities in Drug Vials Intended for Intravitreal Medication
title_fullStr Impurities in Drug Vials Intended for Intravitreal Medication
title_full_unstemmed Impurities in Drug Vials Intended for Intravitreal Medication
title_short Impurities in Drug Vials Intended for Intravitreal Medication
title_sort impurities in drug vials intended for intravitreal medication
topic Case Series
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8142807/
https://www.ncbi.nlm.nih.gov/pubmed/34055435
http://dx.doi.org/10.1155/2020/8824585
work_keys_str_mv AT pohllisa impuritiesindrugvialsintendedforintravitrealmedication
AT strudellisa impuritiesindrugvialsintendedforintravitrealmedication
AT dimopoulosspyridon impuritiesindrugvialsintendedforintravitrealmedication
AT ziemssenfocke impuritiesindrugvialsintendedforintravitrealmedication