Cargando…
Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures
INTRODUCTION: All-in-one parenteral nutrition (AIO-PN) is essential for patients with limited venous access, e.g. premature infants. So far, there are still some conflicting data related to the stability of AIO-PN. The aim of this study is to examine the physical stability and sterility of AIO-PN as...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8142921/ https://www.ncbi.nlm.nih.gov/pubmed/34084045 http://dx.doi.org/10.4103/jpbs.JPBS_278_19 |
_version_ | 1783696648256356352 |
---|---|
author | Hanifah, Suci Maulidani, Yuli Nugroho, Bambang Hernawan Sari, Chynthia Pradiftha |
author_facet | Hanifah, Suci Maulidani, Yuli Nugroho, Bambang Hernawan Sari, Chynthia Pradiftha |
author_sort | Hanifah, Suci |
collection | PubMed |
description | INTRODUCTION: All-in-one parenteral nutrition (AIO-PN) is essential for patients with limited venous access, e.g. premature infants. So far, there are still some conflicting data related to the stability of AIO-PN. The aim of this study is to examine the physical stability and sterility of AIO-PN as it was being stored at room and cold temperature. MATERIALS AND METHODS: AIO-PN contains dextrose, amino acid, lipid, sodium chloride, magnesium sulfate, potassium chloride, calcium gluconate, and vitamin. Formulation of AIO-PN was prepared based on the guidance of nutrition for 3-day-old preterm baby weighing 1000 g. The formulation of AIO-PN then was stored at room temperature (25.43ºC ± 0.54) and cold temperature (6.2ºC ± 2.04). RESULTS AND DISCUSSION: Based on the experiments, all formulas confidently fulfilled the sterile criteria, in which there is no microbial growth in the formula within 7 days. During those days, the droplet size of all formulas was under the range (<500 nm) with a good range of pH. However, during the process of storing under the room temperature, AIO-PN showed the reversible creaming starting on day 2 and the discoloration starting on day 4. Meanwhile, we found that there are no such physical changes in the formula within 7 days under the cold temperature. CONCLUSION: This research confirmed that AIO-PN that is being stored at room temperature cannot be used starting on day 4, but the formulation storage under the cold temperature is still accepted within 7 days. |
format | Online Article Text |
id | pubmed-8142921 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-81429212021-06-02 Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures Hanifah, Suci Maulidani, Yuli Nugroho, Bambang Hernawan Sari, Chynthia Pradiftha J Pharm Bioallied Sci Original Article INTRODUCTION: All-in-one parenteral nutrition (AIO-PN) is essential for patients with limited venous access, e.g. premature infants. So far, there are still some conflicting data related to the stability of AIO-PN. The aim of this study is to examine the physical stability and sterility of AIO-PN as it was being stored at room and cold temperature. MATERIALS AND METHODS: AIO-PN contains dextrose, amino acid, lipid, sodium chloride, magnesium sulfate, potassium chloride, calcium gluconate, and vitamin. Formulation of AIO-PN was prepared based on the guidance of nutrition for 3-day-old preterm baby weighing 1000 g. The formulation of AIO-PN then was stored at room temperature (25.43ºC ± 0.54) and cold temperature (6.2ºC ± 2.04). RESULTS AND DISCUSSION: Based on the experiments, all formulas confidently fulfilled the sterile criteria, in which there is no microbial growth in the formula within 7 days. During those days, the droplet size of all formulas was under the range (<500 nm) with a good range of pH. However, during the process of storing under the room temperature, AIO-PN showed the reversible creaming starting on day 2 and the discoloration starting on day 4. Meanwhile, we found that there are no such physical changes in the formula within 7 days under the cold temperature. CONCLUSION: This research confirmed that AIO-PN that is being stored at room temperature cannot be used starting on day 4, but the formulation storage under the cold temperature is still accepted within 7 days. Wolters Kluwer - Medknow 2021 2020-12-16 /pmc/articles/PMC8142921/ /pubmed/34084045 http://dx.doi.org/10.4103/jpbs.JPBS_278_19 Text en Copyright: © 2020 Journal of Pharmacy and Bioallied Sciences https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Hanifah, Suci Maulidani, Yuli Nugroho, Bambang Hernawan Sari, Chynthia Pradiftha Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title | Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title_full | Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title_fullStr | Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title_full_unstemmed | Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title_short | Provision of Standardized All-in-One Parenteral Nutrition (AIO-PN) for Very Preterm Neonates: Evaluation at Room and Cold Temperatures |
title_sort | provision of standardized all-in-one parenteral nutrition (aio-pn) for very preterm neonates: evaluation at room and cold temperatures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8142921/ https://www.ncbi.nlm.nih.gov/pubmed/34084045 http://dx.doi.org/10.4103/jpbs.JPBS_278_19 |
work_keys_str_mv | AT hanifahsuci provisionofstandardizedallinoneparenteralnutritionaiopnforverypretermneonatesevaluationatroomandcoldtemperatures AT maulidaniyuli provisionofstandardizedallinoneparenteralnutritionaiopnforverypretermneonatesevaluationatroomandcoldtemperatures AT nugrohobambanghernawan provisionofstandardizedallinoneparenteralnutritionaiopnforverypretermneonatesevaluationatroomandcoldtemperatures AT sarichynthiapradiftha provisionofstandardizedallinoneparenteralnutritionaiopnforverypretermneonatesevaluationatroomandcoldtemperatures |