Cargando…

Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia

Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prev...

Descripción completa

Detalles Bibliográficos
Autores principales: Chong, Zhuo Lin, Soe, Hui Jen, Ismail, Amni Adilah, Mahboob, Tooba, Chandramathi, Samudi, Sekaran, Shamala Devi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8143448/
https://www.ncbi.nlm.nih.gov/pubmed/33921935
http://dx.doi.org/10.3390/bios11050129
_version_ 1783696755836059648
author Chong, Zhuo Lin
Soe, Hui Jen
Ismail, Amni Adilah
Mahboob, Tooba
Chandramathi, Samudi
Sekaran, Shamala Devi
author_facet Chong, Zhuo Lin
Soe, Hui Jen
Ismail, Amni Adilah
Mahboob, Tooba
Chandramathi, Samudi
Sekaran, Shamala Devi
author_sort Chong, Zhuo Lin
collection PubMed
description Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prevention, especially vaccination, to reduce dengue morbidity. This study evaluated ViroTrack Dengue Serostate, a biosensors-based semi-quantitative anti-dengue IgG (immunoglobulin G) immuno-magnetic agglutination assay for the diagnosis of previous and recent dengue in a single test. Blood samples were obtained from 484 healthy participants recruited randomly from two communities in Petaling district, Selangor, Malaysia. The reference tests were Panbio Dengue IgG indirect and capture enzyme-linked immunosorbent assays, in-house hemagglutination inhibition assay, and focus reduction neutralization test. Dengue Serostate had a sensitivity and specificity of 91.1% (95%CI 87.8–93.8) and 91.1% (95%CI 83.8–95.8) for the diagnosis of previous dengue, and 90.2% (95%CI 76.9–97.3) and 93.2% (95%CI 90.5–95.4) for the diagnosis of recent dengue, respectively. Its positive predictive value of 97.5% (95%CI 95.3–98.8) would prevent most dengue-naïve individuals from being vaccinated. ViroTrack Dengue Serostate’s good point-of-care diagnostic accuracy can ease the conduct of dengue serosurveys to inform dengue vaccination strategy and facilitate pre-vaccination screening to ensure safety.
format Online
Article
Text
id pubmed-8143448
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81434482021-05-25 Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia Chong, Zhuo Lin Soe, Hui Jen Ismail, Amni Adilah Mahboob, Tooba Chandramathi, Samudi Sekaran, Shamala Devi Biosensors (Basel) Article Dengue is a major threat to public health globally. While point-of-care diagnosis of acute/recent dengue is available to reduce its mortality, a lack of rapid and accurate testing for the detection of previous dengue remains a hurdle in expanding dengue seroepidemiological surveys to inform its prevention, especially vaccination, to reduce dengue morbidity. This study evaluated ViroTrack Dengue Serostate, a biosensors-based semi-quantitative anti-dengue IgG (immunoglobulin G) immuno-magnetic agglutination assay for the diagnosis of previous and recent dengue in a single test. Blood samples were obtained from 484 healthy participants recruited randomly from two communities in Petaling district, Selangor, Malaysia. The reference tests were Panbio Dengue IgG indirect and capture enzyme-linked immunosorbent assays, in-house hemagglutination inhibition assay, and focus reduction neutralization test. Dengue Serostate had a sensitivity and specificity of 91.1% (95%CI 87.8–93.8) and 91.1% (95%CI 83.8–95.8) for the diagnosis of previous dengue, and 90.2% (95%CI 76.9–97.3) and 93.2% (95%CI 90.5–95.4) for the diagnosis of recent dengue, respectively. Its positive predictive value of 97.5% (95%CI 95.3–98.8) would prevent most dengue-naïve individuals from being vaccinated. ViroTrack Dengue Serostate’s good point-of-care diagnostic accuracy can ease the conduct of dengue serosurveys to inform dengue vaccination strategy and facilitate pre-vaccination screening to ensure safety. MDPI 2021-04-22 /pmc/articles/PMC8143448/ /pubmed/33921935 http://dx.doi.org/10.3390/bios11050129 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chong, Zhuo Lin
Soe, Hui Jen
Ismail, Amni Adilah
Mahboob, Tooba
Chandramathi, Samudi
Sekaran, Shamala Devi
Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title_full Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title_fullStr Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title_full_unstemmed Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title_short Evaluation of the Diagnostic Accuracy of a New Biosensors-Based Rapid Diagnostic Test for the Point-Of-Care Diagnosis of Previous and Recent Dengue Infections in Malaysia
title_sort evaluation of the diagnostic accuracy of a new biosensors-based rapid diagnostic test for the point-of-care diagnosis of previous and recent dengue infections in malaysia
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8143448/
https://www.ncbi.nlm.nih.gov/pubmed/33921935
http://dx.doi.org/10.3390/bios11050129
work_keys_str_mv AT chongzhuolin evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia
AT soehuijen evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia
AT ismailamniadilah evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia
AT mahboobtooba evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia
AT chandramathisamudi evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia
AT sekaranshamaladevi evaluationofthediagnosticaccuracyofanewbiosensorsbasedrapiddiagnostictestforthepointofcarediagnosisofpreviousandrecentdengueinfectionsinmalaysia