Cargando…

Application of a Proposed Multi-Positional Circumferential Arm Liposuction Method and Quantification of its Clinical Efficacy Evaluation

BACKGROUND: Upper arm liposuction mainly focuses on the posterolateral region, which may lead to a lack of harmony between the aspirated and unaspirated areas. In addition, the treatment effect of arm liposuction is often evaluated only by preoperative and postoperative photograph comparison and sim...

Descripción completa

Detalles Bibliográficos
Autores principales: Gu, Yunpeng, Kang, Ning, Lv, Qianwen, Qi, Yue, Liu, Zhenjun, Chen, Weiwei, Sun, Xuejian, Chen, Haodong, Ma, Gui-e, Qi, Zuoliang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144089/
https://www.ncbi.nlm.nih.gov/pubmed/33528617
http://dx.doi.org/10.1007/s00266-020-02121-2
Descripción
Sumario:BACKGROUND: Upper arm liposuction mainly focuses on the posterolateral region, which may lead to a lack of harmony between the aspirated and unaspirated areas. In addition, the treatment effect of arm liposuction is often evaluated only by preoperative and postoperative photograph comparison and simple measurement; quantitative research on this topic is still lacking. METHODS: The multi-positional circumferential arm liposuction (MCAL) technique was proposed and applied to a total of 34 females in our hospital from 2017 to 2019. Three-dimensional data of 12 patients before the operation and after 2–3 months were collected and processed by 3D imaging, and the volume reduction rate was evaluated quantitatively. RESULTS: The MCAL method was successfully applied in the clinic, and its surgical effect was quantitatively studied. The mean follow-up time of 12 patients was (75.2 ±13.1) days, and the postoperative volume was significantly reduced. The postoperative volume of patients with type I, type II and type III decreased by (10.79 ±2.55)%, (17.25 ±3.02)% and (22.76 ±3.51)%, respectively. CONCLUSION: Our new MCAL technique was successful, maximizing the esthetic results in upper limb contour refinements in the superficial fascial layer. The clinical efficacy of this proposed MCAL method was evaluated by CT and 3D digital technology, which provided further accuracy in demonstrating its effect on the shape of the arm. LEVEL OF EVIDENCE IV: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors https://www.springer.com. SUPPLEMENTARY INFORMATION: The online version of this article (10.1007/s00266-020-02121-2) contains supplementary material, which is available to authorized users.