Cargando…

Bicycle spiroergometry: comparison of standardized examination protocols for adolescents: is it necessary to define own standard values for each protocol?

PURPOSE: To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol. METHODS: One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Windhaber, Jana, Steinbauer, Monica, Holter, Magdalena, Wieland, Annemarie, Kogler, Kristina, Riedl, Regina, Schober, Peter, Castellani, Christoph, Singer, Georg, Till, Holger
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144119/
https://www.ncbi.nlm.nih.gov/pubmed/33712869
http://dx.doi.org/10.1007/s00421-021-04601-y
Descripción
Sumario:PURPOSE: To compare performance data of adolescents collected with five different bicycle spiroergometry protocols and to assess the necessity for establishing standard values for each protocol. METHODS: One-hundred-twenty adolescents completed two bicycle spiroergometries within 14 days. One of the two tests was performed based on our institutional weight-adapted protocol (P0). The other test was performed based on one out of four exercise protocols widely used for children and adolescents (P1, 2, 3 or 4) with 30 persons each. The two tests were performed in a random order. Routine parameters of cardiopulmonary exercise tests (CPET) such as VO(2)peak, maximum power, O(2) pulse, OUES, VE/VCO(2) slope as well as ventilatory and lactate thresholds were investigated. Agreement between protocols was evaluated by Bland–Altman analysis, coefficients of variation (CV) and intra-class correlation coefficients (ICC). RESULTS: None of the CPET parameters were significantly different between P0 and P1, 2, 3 or 4. For most of the parameters, low biases between P0 and P1–P4 were found and 95% confidence intervalls were narrow. CV and ICC values largely corresponded to well-defined analytical goals (CV < 10% and ICC > 0.9). Only maximal power (Pmax) showed differences in size and drift of the bias depending on the length of the step duration of the protocols. CONCLUSION: Comparability between examination protocols has been shown for CPET parameters independent on step duration. Protocol-dependent standard values do not appear to be necessary. Only Pmax is dependent on the step duration, but in most cases, this has no significant influence on the fitness assessment.