Cargando…

Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial

Expanded hemodialysis (HDx) with medium cutoff (MCO) membranes, which remove middle-to-large molecules well, may be a good option to replace online hemodiafiltration (online-HDF). To provide more evidence, this randomized controlled trial compared several cardiovascular parameters between patients u...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Yeonhee, Jang, Myoung-jin, Jeon, Junseok, Lee, Jung Eun, Huh, Wooseong, Choi, Bum Soon, Park, Cheol Whee, Chin, Ho Jun, Kang, Chae Lin, Kim, Dong Ki, Han, Seung Seok, Joo, Kwon Wook
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144214/
https://www.ncbi.nlm.nih.gov/pubmed/34031503
http://dx.doi.org/10.1038/s41598-021-90311-6
_version_ 1783696915350683648
author Lee, Yeonhee
Jang, Myoung-jin
Jeon, Junseok
Lee, Jung Eun
Huh, Wooseong
Choi, Bum Soon
Park, Cheol Whee
Chin, Ho Jun
Kang, Chae Lin
Kim, Dong Ki
Han, Seung Seok
Joo, Kwon Wook
author_facet Lee, Yeonhee
Jang, Myoung-jin
Jeon, Junseok
Lee, Jung Eun
Huh, Wooseong
Choi, Bum Soon
Park, Cheol Whee
Chin, Ho Jun
Kang, Chae Lin
Kim, Dong Ki
Han, Seung Seok
Joo, Kwon Wook
author_sort Lee, Yeonhee
collection PubMed
description Expanded hemodialysis (HDx) with medium cutoff (MCO) membranes, which remove middle-to-large molecules well, may be a good option to replace online hemodiafiltration (online-HDF). To provide more evidence, this randomized controlled trial compared several cardiovascular parameters between patients undergoing HDx and online-HDF. Eighty patients undergoing thrice-weekly hemodialysis were randomly assigned to receive either HDx with a Theranova membrane (n = 43) or online-HDF (n = 37). The primary endpoints were changes in brachial-ankle pulse wave velocity (baPWV), echocardiographic parameters, and coronary artery calcium (CAC) scores over 1 year, and the secondary endpoints included blood cardiovascular biomarkers, mortality, and patient-reported outcomes. A linear mixed model and log-rank test were used to estimate the group differences. 65 patients had completed the trial. The changes in baPWV and echocardiographic parameters did not differ between the two groups. The CAC scores remained stable in the online-HDF group, whereas an increasing trend was shown in the HDx group (P = 0.012). Other endpoints, including cardiovascular and all-cause mortalities, were similar between the two groups. The changes in cardiovascular parameters did not differ between HDx with an MCO membrane and online-HDF. However, attention may be needed in patients with high CAC scores or scores with an increasing tendency when online-HDF is replaced with HDx with an MCO membrane.
format Online
Article
Text
id pubmed-8144214
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-81442142021-05-25 Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial Lee, Yeonhee Jang, Myoung-jin Jeon, Junseok Lee, Jung Eun Huh, Wooseong Choi, Bum Soon Park, Cheol Whee Chin, Ho Jun Kang, Chae Lin Kim, Dong Ki Han, Seung Seok Joo, Kwon Wook Sci Rep Article Expanded hemodialysis (HDx) with medium cutoff (MCO) membranes, which remove middle-to-large molecules well, may be a good option to replace online hemodiafiltration (online-HDF). To provide more evidence, this randomized controlled trial compared several cardiovascular parameters between patients undergoing HDx and online-HDF. Eighty patients undergoing thrice-weekly hemodialysis were randomly assigned to receive either HDx with a Theranova membrane (n = 43) or online-HDF (n = 37). The primary endpoints were changes in brachial-ankle pulse wave velocity (baPWV), echocardiographic parameters, and coronary artery calcium (CAC) scores over 1 year, and the secondary endpoints included blood cardiovascular biomarkers, mortality, and patient-reported outcomes. A linear mixed model and log-rank test were used to estimate the group differences. 65 patients had completed the trial. The changes in baPWV and echocardiographic parameters did not differ between the two groups. The CAC scores remained stable in the online-HDF group, whereas an increasing trend was shown in the HDx group (P = 0.012). Other endpoints, including cardiovascular and all-cause mortalities, were similar between the two groups. The changes in cardiovascular parameters did not differ between HDx with an MCO membrane and online-HDF. However, attention may be needed in patients with high CAC scores or scores with an increasing tendency when online-HDF is replaced with HDx with an MCO membrane. Nature Publishing Group UK 2021-05-24 /pmc/articles/PMC8144214/ /pubmed/34031503 http://dx.doi.org/10.1038/s41598-021-90311-6 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Lee, Yeonhee
Jang, Myoung-jin
Jeon, Junseok
Lee, Jung Eun
Huh, Wooseong
Choi, Bum Soon
Park, Cheol Whee
Chin, Ho Jun
Kang, Chae Lin
Kim, Dong Ki
Han, Seung Seok
Joo, Kwon Wook
Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title_full Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title_fullStr Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title_full_unstemmed Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title_short Cardiovascular Risk Comparison between Expanded Hemodialysis Using Theranova and Online Hemodiafiltration (CARTOON): A Multicenter Randomized Controlled Trial
title_sort cardiovascular risk comparison between expanded hemodialysis using theranova and online hemodiafiltration (cartoon): a multicenter randomized controlled trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144214/
https://www.ncbi.nlm.nih.gov/pubmed/34031503
http://dx.doi.org/10.1038/s41598-021-90311-6
work_keys_str_mv AT leeyeonhee cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT jangmyoungjin cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT jeonjunseok cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT leejungeun cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT huhwooseong cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT choibumsoon cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT parkcheolwhee cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT chinhojun cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT kangchaelin cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT kimdongki cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT hanseungseok cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial
AT jookwonwook cardiovascularriskcomparisonbetweenexpandedhemodialysisusingtheranovaandonlinehemodiafiltrationcartoonamulticenterrandomizedcontrolledtrial