Cargando…
Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans
OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants. MAT...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144255/ https://www.ncbi.nlm.nih.gov/pubmed/34031775 http://dx.doi.org/10.1186/s40729-021-00329-8 |
_version_ | 1783696919395041280 |
---|---|
author | Iglhaut, Gerhard Salomon, Sebastian Fretwurst, Tobias Thomas, Peter Endres, Janina Kessler, Selina Summer, Burkhard |
author_facet | Iglhaut, Gerhard Salomon, Sebastian Fretwurst, Tobias Thomas, Peter Endres, Janina Kessler, Selina Summer, Burkhard |
author_sort | Iglhaut, Gerhard |
collection | PubMed |
description | OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants. MATERIAL AND METHODS: A total of 40 patients with one titanium implant, half of them (n=20) provided with a M abutment (control group) and the other half (n=20) with LMS abutments (test group), were included in the study. Clinical parameters pocket probing depth (PD), full-mouth plaque score (FMPS), radiographic bone loss (RBL), clinical attachment level (CAL), mucosal recession (MR), bleeding on probing (BOP), and width of keratinized mucosa (KM) were evaluated. The peri-implant sulcus fluid was analyzed for cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10 via flow cytometry. RESULTS: Clinical evaluation demonstrated no significant difference of PD (mean LMS = 3.50 mm/SD 0.95 mm vs mean M = 3.45 mm/SD 0.76 mm (p=0.855)), MR (mean LMS = 0.30 mm/SD 0.57 mm vs mean M = 0.35 mm/SD 0.67 mm (p=0.801)), CAL (mean LMS = 3.60 mm/SD 1.14 mm vs mean M = 3.55 mm/SD 0.89 mm (p=0.878)), and KM (mean LMS = 2.03 mm/SD 1.08 mm vs mean M = 2.13 mm/SD 0.92 mm (p=0.754)) between LMS and M abutments. LMS abutments showed less BOP than M abutments (26.7% vs 30.8%), but statistically not significant (p = 0.2235). Radiographic bone loss (mean LMS = 0.22 mm/SD 0.44 mm vs mean M = 0.59 mm/SD 0.49 mm) was reduced in the test group in comparison with the control group (p=0.016). In the collected PICF, the levels of pro-inflammatory cytokines IL-1α (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p=0.968)) and IL-1β (median LMS = 60.43 pg/ml vs M = 83.11 pg/ml (p=0.4777)) were lower, and the levels of IL-6 (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p<0.0001)) were significantly lower in the test group. In contrast, the levels of IL-8 (median LMS = 255.7 pg/ml vs M = 178.7 pg/ml (p=0.3306)) were higher in the test group, though not significantly. The levels of anti-inflammatory IL-10 were significantly increased in the test group (LMS median = 0.555 pg/ml vs M median = 0.465 pg/ml (p=0.0365)). IL-1β showed a significant correlation to radiologic bone loss (p=0.0024). The other variables IL-1α, IL-6, IL-8, and IL-10 had no significant correlation to radiological bone loss. CONCLUSION: Within the limitations of this study, titanium implants provided with laser-microtextured surface abutments seem to demonstrate less pro-inflammatory and more anti-inflammatory activity and to show reduced radiographic bone loss compared to machined titanium abutments. CLINICAL RELEVANCE: The use of laser-microtextured surface abutments might have the potential to support peri-implant tissue health. |
format | Online Article Text |
id | pubmed-8144255 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-81442552021-06-09 Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans Iglhaut, Gerhard Salomon, Sebastian Fretwurst, Tobias Thomas, Peter Endres, Janina Kessler, Selina Summer, Burkhard Int J Implant Dent Research OBJECTIVE: The objective of the present study was to examine the clinical and immunological parameters in samples collected from the peri-implant crevicular fluid (PICF) of machined titanium (M) abutments compared to titanium abutments with a laser-microtextured surface (LMS) on dental implants. MATERIAL AND METHODS: A total of 40 patients with one titanium implant, half of them (n=20) provided with a M abutment (control group) and the other half (n=20) with LMS abutments (test group), were included in the study. Clinical parameters pocket probing depth (PD), full-mouth plaque score (FMPS), radiographic bone loss (RBL), clinical attachment level (CAL), mucosal recession (MR), bleeding on probing (BOP), and width of keratinized mucosa (KM) were evaluated. The peri-implant sulcus fluid was analyzed for cytokines IL-1α, IL-1β, IL-6, IL-8, and IL-10 via flow cytometry. RESULTS: Clinical evaluation demonstrated no significant difference of PD (mean LMS = 3.50 mm/SD 0.95 mm vs mean M = 3.45 mm/SD 0.76 mm (p=0.855)), MR (mean LMS = 0.30 mm/SD 0.57 mm vs mean M = 0.35 mm/SD 0.67 mm (p=0.801)), CAL (mean LMS = 3.60 mm/SD 1.14 mm vs mean M = 3.55 mm/SD 0.89 mm (p=0.878)), and KM (mean LMS = 2.03 mm/SD 1.08 mm vs mean M = 2.13 mm/SD 0.92 mm (p=0.754)) between LMS and M abutments. LMS abutments showed less BOP than M abutments (26.7% vs 30.8%), but statistically not significant (p = 0.2235). Radiographic bone loss (mean LMS = 0.22 mm/SD 0.44 mm vs mean M = 0.59 mm/SD 0.49 mm) was reduced in the test group in comparison with the control group (p=0.016). In the collected PICF, the levels of pro-inflammatory cytokines IL-1α (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p=0.968)) and IL-1β (median LMS = 60.43 pg/ml vs M = 83.11 pg/ml (p=0.4777)) were lower, and the levels of IL-6 (median LMS = 180.8 pg/ml vs M = 200.9 pg/ml (p<0.0001)) were significantly lower in the test group. In contrast, the levels of IL-8 (median LMS = 255.7 pg/ml vs M = 178.7 pg/ml (p=0.3306)) were higher in the test group, though not significantly. The levels of anti-inflammatory IL-10 were significantly increased in the test group (LMS median = 0.555 pg/ml vs M median = 0.465 pg/ml (p=0.0365)). IL-1β showed a significant correlation to radiologic bone loss (p=0.0024). The other variables IL-1α, IL-6, IL-8, and IL-10 had no significant correlation to radiological bone loss. CONCLUSION: Within the limitations of this study, titanium implants provided with laser-microtextured surface abutments seem to demonstrate less pro-inflammatory and more anti-inflammatory activity and to show reduced radiographic bone loss compared to machined titanium abutments. CLINICAL RELEVANCE: The use of laser-microtextured surface abutments might have the potential to support peri-implant tissue health. Springer Berlin Heidelberg 2021-05-25 /pmc/articles/PMC8144255/ /pubmed/34031775 http://dx.doi.org/10.1186/s40729-021-00329-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Iglhaut, Gerhard Salomon, Sebastian Fretwurst, Tobias Thomas, Peter Endres, Janina Kessler, Selina Summer, Burkhard Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title | Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title_full | Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title_fullStr | Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title_full_unstemmed | Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title_short | Cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
title_sort | cross-sectional evaluation of clinical and immunological parameters at partially microgrooved vs machined abutments in humans |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144255/ https://www.ncbi.nlm.nih.gov/pubmed/34031775 http://dx.doi.org/10.1186/s40729-021-00329-8 |
work_keys_str_mv | AT iglhautgerhard crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT salomonsebastian crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT fretwursttobias crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT thomaspeter crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT endresjanina crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT kesslerselina crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans AT summerburkhard crosssectionalevaluationofclinicalandimmunologicalparametersatpartiallymicrogroovedvsmachinedabutmentsinhumans |