Cargando…

3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis

BACKGROUND & OBJECTIVE: The application of ultrasound imaging for spine evaluation could minimize radiation exposure for patients with adolescence idiopathic scoliosis (AIS). A customized three-dimensional (3D) ultrasound imaging system has been demonstrated to provide reliable and valid coronal...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Timothy Tin-Yan, Lai, Kelly Ka-Lee, Cheng, Jack Chun-Yiu, Castelein, René Marten, Lam, Tsz-Ping, Zheng, Yong-Ping
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chinese Speaking Orthopaedic Society 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144340/
https://www.ncbi.nlm.nih.gov/pubmed/34094858
http://dx.doi.org/10.1016/j.jot.2021.04.007
_version_ 1783696935716126720
author Lee, Timothy Tin-Yan
Lai, Kelly Ka-Lee
Cheng, Jack Chun-Yiu
Castelein, René Marten
Lam, Tsz-Ping
Zheng, Yong-Ping
author_facet Lee, Timothy Tin-Yan
Lai, Kelly Ka-Lee
Cheng, Jack Chun-Yiu
Castelein, René Marten
Lam, Tsz-Ping
Zheng, Yong-Ping
author_sort Lee, Timothy Tin-Yan
collection PubMed
description BACKGROUND & OBJECTIVE: The application of ultrasound imaging for spine evaluation could minimize radiation exposure for patients with adolescence idiopathic scoliosis (AIS). A customized three-dimensional (3D) ultrasound imaging system has been demonstrated to provide reliable and valid coronal curvature measurements. However, these measurements were using the spinous processes as anatomical reference, leading to a predictable underestimation of the traditionally used Cobb angles. An alternative 3D ultrasound image reconstruction method was applied to create coronal images with more lateral features for angle measurement. The objective of this study was to test the reliability and the validity of this angle, the ultrasound curve angle (UCA), and compare the UCA with the Cobb angles on X-ray images of patients with AIS. MATERIALS AND METHODS: This study was divided into: 1) Investigation of intra- and inter-reliability between two raters for measuring the UCA and two operators for acquiring ultrasound images; 2) Investigation of the validity between the radiographic Cobb angle and the UCA. Fifty patients and 164 patients with AIS, were included in the two stages, respectively. Patients underwent bi-planar X-ray and 3D ultrasound scanning on the same day. The proposed UCA was used to measure the coronal curvature from the ultrasound coronal images, which were formed using a newly customized volume projection imaging (VPI) method. The intra-rater/operator and inter-rater and operator reliability of the UCA were tested by intra-class correlation coefficient (ICC) (3,1) and (2,1), respectively. The validity of UCA measurements as compared to radiographic Cobb angles was tested by inter-method ICC (2,1), mean absolute difference (MAD), standard error of measurement (SEM), Pearson correlation coefficient and Bland–Altman statistics. The level of significance was set as 0.05. RESULTS: Excellent intra-rater and intra-operator (ICC (3,1)≥0.973) and excellent inter-rater and inter-operator reliability (ICC (2,1)≥0.925) for UCA measurement, with overall MAD and SEM no more than 3.5° and 1.7° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. Very good correlations were observed between UCA and Cobb angle for main thoracic ([Formula: see text] =0.893) and (thoraco)lumbar ([Formula: see text] =0.884) curves. The mean (SD) measurements in terms of radiographic Cobb and UCA were 27.2 ​± ​11.6° and 26.3 ​± ​11.4° for main thoracic curves; and 26.2 ​± ​11.4° and 24.8 ​± ​9.7° for (thoraco)lumbar curve respectively. One hundred sixty-four subjects (33 male and 131 female subjects; 11–18 years of age, mean of 15.1 ​± ​1.9 years) were included for the validity session. Excellent inter-method variations (ICC (2,K) ≥0.933) with overall MAD and SEM no more than 3.0° and 1.5° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. In addition, Bland–Altman plots demonstrated an acceptable agreement between ultrasound and radiographic Cobb measurements. CONCLUSION: In this study, very good correlations and agreement were demonstrated between the ultrasound and X-ray measurements of the scoliotic curvature. Judging from the promising results of this study, patients with AIS with different severity of curves can be evaluated and monitored by ultrasound imaging, reducing the usage of radiation during follow-ups. This method could also be used for scoliosis screening. The Translational potential of this article: Ultrasound curve angle (UCA) obtained from 3D ultrasound imaging system can provide reliable and valid evaluation on coronal curvature for patients with AIS, without the need of radiation.
format Online
Article
Text
id pubmed-8144340
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Chinese Speaking Orthopaedic Society
record_format MEDLINE/PubMed
spelling pubmed-81443402021-06-04 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis Lee, Timothy Tin-Yan Lai, Kelly Ka-Lee Cheng, Jack Chun-Yiu Castelein, René Marten Lam, Tsz-Ping Zheng, Yong-Ping J Orthop Translat Original Article BACKGROUND & OBJECTIVE: The application of ultrasound imaging for spine evaluation could minimize radiation exposure for patients with adolescence idiopathic scoliosis (AIS). A customized three-dimensional (3D) ultrasound imaging system has been demonstrated to provide reliable and valid coronal curvature measurements. However, these measurements were using the spinous processes as anatomical reference, leading to a predictable underestimation of the traditionally used Cobb angles. An alternative 3D ultrasound image reconstruction method was applied to create coronal images with more lateral features for angle measurement. The objective of this study was to test the reliability and the validity of this angle, the ultrasound curve angle (UCA), and compare the UCA with the Cobb angles on X-ray images of patients with AIS. MATERIALS AND METHODS: This study was divided into: 1) Investigation of intra- and inter-reliability between two raters for measuring the UCA and two operators for acquiring ultrasound images; 2) Investigation of the validity between the radiographic Cobb angle and the UCA. Fifty patients and 164 patients with AIS, were included in the two stages, respectively. Patients underwent bi-planar X-ray and 3D ultrasound scanning on the same day. The proposed UCA was used to measure the coronal curvature from the ultrasound coronal images, which were formed using a newly customized volume projection imaging (VPI) method. The intra-rater/operator and inter-rater and operator reliability of the UCA were tested by intra-class correlation coefficient (ICC) (3,1) and (2,1), respectively. The validity of UCA measurements as compared to radiographic Cobb angles was tested by inter-method ICC (2,1), mean absolute difference (MAD), standard error of measurement (SEM), Pearson correlation coefficient and Bland–Altman statistics. The level of significance was set as 0.05. RESULTS: Excellent intra-rater and intra-operator (ICC (3,1)≥0.973) and excellent inter-rater and inter-operator reliability (ICC (2,1)≥0.925) for UCA measurement, with overall MAD and SEM no more than 3.5° and 1.7° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. Very good correlations were observed between UCA and Cobb angle for main thoracic ([Formula: see text] =0.893) and (thoraco)lumbar ([Formula: see text] =0.884) curves. The mean (SD) measurements in terms of radiographic Cobb and UCA were 27.2 ​± ​11.6° and 26.3 ​± ​11.4° for main thoracic curves; and 26.2 ​± ​11.4° and 24.8 ​± ​9.7° for (thoraco)lumbar curve respectively. One hundred sixty-four subjects (33 male and 131 female subjects; 11–18 years of age, mean of 15.1 ​± ​1.9 years) were included for the validity session. Excellent inter-method variations (ICC (2,K) ≥0.933) with overall MAD and SEM no more than 3.0° and 1.5° were demonstrated for both main thoracic and (thoraco)lumbar curvatures. In addition, Bland–Altman plots demonstrated an acceptable agreement between ultrasound and radiographic Cobb measurements. CONCLUSION: In this study, very good correlations and agreement were demonstrated between the ultrasound and X-ray measurements of the scoliotic curvature. Judging from the promising results of this study, patients with AIS with different severity of curves can be evaluated and monitored by ultrasound imaging, reducing the usage of radiation during follow-ups. This method could also be used for scoliosis screening. The Translational potential of this article: Ultrasound curve angle (UCA) obtained from 3D ultrasound imaging system can provide reliable and valid evaluation on coronal curvature for patients with AIS, without the need of radiation. Chinese Speaking Orthopaedic Society 2021-05-19 /pmc/articles/PMC8144340/ /pubmed/34094858 http://dx.doi.org/10.1016/j.jot.2021.04.007 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Lee, Timothy Tin-Yan
Lai, Kelly Ka-Lee
Cheng, Jack Chun-Yiu
Castelein, René Marten
Lam, Tsz-Ping
Zheng, Yong-Ping
3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title_full 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title_fullStr 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title_full_unstemmed 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title_short 3D ultrasound imaging provides reliable angle measurement with validity comparable to X-ray in patients with adolescent idiopathic scoliosis
title_sort 3d ultrasound imaging provides reliable angle measurement with validity comparable to x-ray in patients with adolescent idiopathic scoliosis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144340/
https://www.ncbi.nlm.nih.gov/pubmed/34094858
http://dx.doi.org/10.1016/j.jot.2021.04.007
work_keys_str_mv AT leetimothytinyan 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis
AT laikellykalee 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis
AT chengjackchunyiu 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis
AT casteleinrenemarten 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis
AT lamtszping 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis
AT zhengyongping 3dultrasoundimagingprovidesreliableanglemeasurementwithvaliditycomparabletoxrayinpatientswithadolescentidiopathicscoliosis