Cargando…

Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period

Purpose: To evaluate technical outcome, diagnostic yield and safety of computed tomographic fluoroscopy-guided percutaneous core needle biopsies in patients with mediastinal masses. Methods: Overall, 155 CT fluoroscopy-guided mediastinal core needle biopsies, performed from March 2010 to June 2020 w...

Descripción completa

Detalles Bibliográficos
Autores principales: Burgard, Caroline, Stahl, Robert, de Figueiredo, Giovanna Negrao, Dinkel, Julien, Liebig, Thomas, Cioni, Dania, Neri, Emanuele, Trumm, Christoph G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144979/
https://www.ncbi.nlm.nih.gov/pubmed/33926046
http://dx.doi.org/10.3390/diagnostics11050781
_version_ 1783697073148788736
author Burgard, Caroline
Stahl, Robert
de Figueiredo, Giovanna Negrao
Dinkel, Julien
Liebig, Thomas
Cioni, Dania
Neri, Emanuele
Trumm, Christoph G.
author_facet Burgard, Caroline
Stahl, Robert
de Figueiredo, Giovanna Negrao
Dinkel, Julien
Liebig, Thomas
Cioni, Dania
Neri, Emanuele
Trumm, Christoph G.
author_sort Burgard, Caroline
collection PubMed
description Purpose: To evaluate technical outcome, diagnostic yield and safety of computed tomographic fluoroscopy-guided percutaneous core needle biopsies in patients with mediastinal masses. Methods: Overall, 155 CT fluoroscopy-guided mediastinal core needle biopsies, performed from March 2010 to June 2020 were included. Size of lesion, size of needle, access path, number of success, number of biopsies per session, diagnostic yield, patient’s position, effective dose, rate of complications, tumor localization, size of tumor and histopathological diagnosis were considered. Post-interventional CT was performed, and patients observed for any complications. Complications were classified per the Society of Interventional Radiology (SIR). Results: 148 patients (age, 54.7 ± 18.2) underwent 155 CT-fluoroscopy-guided percutaneous biopsies with tumors in the anterior (114; 73.5%), middle (17; 11%) and posterior (24; 15.5%) mediastinum, of which 152 (98%) were technically successful. For placement of the biopsy needle, in 82 (52.9%) procedures a parasternal trajectory was chosen, in 36 (23.3%) a paravertebral access, in 20 (12.9%) through the lateral intercostal space and in 17 (11%) the thoracic anterior midline, respectively. A total of 136 (89.5%) of the biopsies were considered adequate for a specific histopathologic analysis. Total DLP (dose-length product) was 575.7 ± 488.8 mGy*cm. Mean lesion size was 6.0 ± 3.3 cm. Neoplastic pathology was diagnosed in 115 (75.7%) biopsies and 35 (23%) biopsy samples showed no evidence of malignancy. Minor complications were observed in 18 (11.6%) procedures and major pneumothorax requiring drainage insertion in 3 interventions (1.9%). Conclusion: CT fluoroscopy-guided percutaneous core needle biopsy of mediastinal masses is an effective and safe procedure for the initial assessment of patients with mediastinal tumors.
format Online
Article
Text
id pubmed-8144979
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81449792021-05-26 Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period Burgard, Caroline Stahl, Robert de Figueiredo, Giovanna Negrao Dinkel, Julien Liebig, Thomas Cioni, Dania Neri, Emanuele Trumm, Christoph G. Diagnostics (Basel) Article Purpose: To evaluate technical outcome, diagnostic yield and safety of computed tomographic fluoroscopy-guided percutaneous core needle biopsies in patients with mediastinal masses. Methods: Overall, 155 CT fluoroscopy-guided mediastinal core needle biopsies, performed from March 2010 to June 2020 were included. Size of lesion, size of needle, access path, number of success, number of biopsies per session, diagnostic yield, patient’s position, effective dose, rate of complications, tumor localization, size of tumor and histopathological diagnosis were considered. Post-interventional CT was performed, and patients observed for any complications. Complications were classified per the Society of Interventional Radiology (SIR). Results: 148 patients (age, 54.7 ± 18.2) underwent 155 CT-fluoroscopy-guided percutaneous biopsies with tumors in the anterior (114; 73.5%), middle (17; 11%) and posterior (24; 15.5%) mediastinum, of which 152 (98%) were technically successful. For placement of the biopsy needle, in 82 (52.9%) procedures a parasternal trajectory was chosen, in 36 (23.3%) a paravertebral access, in 20 (12.9%) through the lateral intercostal space and in 17 (11%) the thoracic anterior midline, respectively. A total of 136 (89.5%) of the biopsies were considered adequate for a specific histopathologic analysis. Total DLP (dose-length product) was 575.7 ± 488.8 mGy*cm. Mean lesion size was 6.0 ± 3.3 cm. Neoplastic pathology was diagnosed in 115 (75.7%) biopsies and 35 (23%) biopsy samples showed no evidence of malignancy. Minor complications were observed in 18 (11.6%) procedures and major pneumothorax requiring drainage insertion in 3 interventions (1.9%). Conclusion: CT fluoroscopy-guided percutaneous core needle biopsy of mediastinal masses is an effective and safe procedure for the initial assessment of patients with mediastinal tumors. MDPI 2021-04-26 /pmc/articles/PMC8144979/ /pubmed/33926046 http://dx.doi.org/10.3390/diagnostics11050781 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Burgard, Caroline
Stahl, Robert
de Figueiredo, Giovanna Negrao
Dinkel, Julien
Liebig, Thomas
Cioni, Dania
Neri, Emanuele
Trumm, Christoph G.
Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title_full Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title_fullStr Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title_full_unstemmed Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title_short Percutaneous CT Fluoroscopy-Guided Core Needle Biopsy of Mediastinal Masses: Technical Outcome and Complications of 155 Procedures during a 10-Year Period
title_sort percutaneous ct fluoroscopy-guided core needle biopsy of mediastinal masses: technical outcome and complications of 155 procedures during a 10-year period
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8144979/
https://www.ncbi.nlm.nih.gov/pubmed/33926046
http://dx.doi.org/10.3390/diagnostics11050781
work_keys_str_mv AT burgardcaroline percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT stahlrobert percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT defigueiredogiovannanegrao percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT dinkeljulien percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT liebigthomas percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT cionidania percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT neriemanuele percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod
AT trummchristophg percutaneousctfluoroscopyguidedcoreneedlebiopsyofmediastinalmassestechnicaloutcomeandcomplicationsof155proceduresduringa10yearperiod