Cargando…

Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results

Custom-made, three-dimensionally-printed (3D) bone prostheses gain increasing importance in the reconstruction of bone defects after musculoskeletal tumor resections. They may allow preservation of little remaining bone stock and ensure joint or limb salvage. However, we believe that by constructing...

Descripción completa

Detalles Bibliográficos
Autores principales: Guder, Wiebke K., Hardes, Jendrik, Nottrott, Markus, Podleska, Lars E., Streitbürger, Arne
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8145557/
https://www.ncbi.nlm.nih.gov/pubmed/33924789
http://dx.doi.org/10.3390/jpm11050351
_version_ 1783697202445549568
author Guder, Wiebke K.
Hardes, Jendrik
Nottrott, Markus
Podleska, Lars E.
Streitbürger, Arne
author_facet Guder, Wiebke K.
Hardes, Jendrik
Nottrott, Markus
Podleska, Lars E.
Streitbürger, Arne
author_sort Guder, Wiebke K.
collection PubMed
description Custom-made, three-dimensionally-printed (3D) bone prostheses gain increasing importance in the reconstruction of bone defects after musculoskeletal tumor resections. They may allow preservation of little remaining bone stock and ensure joint or limb salvage. However, we believe that by constructing anatomy-imitating implants with highly cancellous titanium alloy (TiAl(6)V(4)) surfaces using 3D printing technology, further benefits such as functional enhancement and reduction of complications may be achieved. We present a case series of four patients reconstructed using custom-made, 3D-printed intercalary monobloc tibia prostheses treated between 2016 and 2020. The mean patient age at operation was 30 years. Tumor resections were performed for Ewing sarcoma (n = 2), high-grade undifferentiated pleomorphic bone sarcoma (n = 1) and adamantinoma (n = 1). Mean resection length was 17.5 cm and mean operation time 147 min. All patients achieved full weight-bearing and limb salvage at a mean follow-up of 21.25 months. One patient developed a non-union at the proximal bone-implant interface. Alteration of implant design prevented non-union in later patients. Mean MSTS and TESS scores were 23.5 and 88. 3D-printed, custom-made intercalary tibia prostheses achieved joint and limb salvage in this case series despite high, published complication rates for biological and endoprosthetic reconstructions of the diaphyseal and distal tibia. Ingrowth of soft tissues into the highly cancellous implant surface structure reduces dead space, enhances function, and appears promising in reducing complication rates.
format Online
Article
Text
id pubmed-8145557
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81455572021-05-26 Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results Guder, Wiebke K. Hardes, Jendrik Nottrott, Markus Podleska, Lars E. Streitbürger, Arne J Pers Med Article Custom-made, three-dimensionally-printed (3D) bone prostheses gain increasing importance in the reconstruction of bone defects after musculoskeletal tumor resections. They may allow preservation of little remaining bone stock and ensure joint or limb salvage. However, we believe that by constructing anatomy-imitating implants with highly cancellous titanium alloy (TiAl(6)V(4)) surfaces using 3D printing technology, further benefits such as functional enhancement and reduction of complications may be achieved. We present a case series of four patients reconstructed using custom-made, 3D-printed intercalary monobloc tibia prostheses treated between 2016 and 2020. The mean patient age at operation was 30 years. Tumor resections were performed for Ewing sarcoma (n = 2), high-grade undifferentiated pleomorphic bone sarcoma (n = 1) and adamantinoma (n = 1). Mean resection length was 17.5 cm and mean operation time 147 min. All patients achieved full weight-bearing and limb salvage at a mean follow-up of 21.25 months. One patient developed a non-union at the proximal bone-implant interface. Alteration of implant design prevented non-union in later patients. Mean MSTS and TESS scores were 23.5 and 88. 3D-printed, custom-made intercalary tibia prostheses achieved joint and limb salvage in this case series despite high, published complication rates for biological and endoprosthetic reconstructions of the diaphyseal and distal tibia. Ingrowth of soft tissues into the highly cancellous implant surface structure reduces dead space, enhances function, and appears promising in reducing complication rates. MDPI 2021-04-28 /pmc/articles/PMC8145557/ /pubmed/33924789 http://dx.doi.org/10.3390/jpm11050351 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Guder, Wiebke K.
Hardes, Jendrik
Nottrott, Markus
Podleska, Lars E.
Streitbürger, Arne
Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title_full Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title_fullStr Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title_full_unstemmed Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title_short Highly Cancellous Titanium Alloy (TiAl(6)V(4)) Surfaces on Three-Dimensionally Printed, Custom-Made Intercalary Tibia Prostheses: Promising Short- to Intermediate-Term Results
title_sort highly cancellous titanium alloy (tial(6)v(4)) surfaces on three-dimensionally printed, custom-made intercalary tibia prostheses: promising short- to intermediate-term results
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8145557/
https://www.ncbi.nlm.nih.gov/pubmed/33924789
http://dx.doi.org/10.3390/jpm11050351
work_keys_str_mv AT guderwiebkek highlycancelloustitaniumalloytial6v4surfacesonthreedimensionallyprintedcustommadeintercalarytibiaprosthesespromisingshorttointermediatetermresults
AT hardesjendrik highlycancelloustitaniumalloytial6v4surfacesonthreedimensionallyprintedcustommadeintercalarytibiaprosthesespromisingshorttointermediatetermresults
AT nottrottmarkus highlycancelloustitaniumalloytial6v4surfacesonthreedimensionallyprintedcustommadeintercalarytibiaprosthesespromisingshorttointermediatetermresults
AT podleskalarse highlycancelloustitaniumalloytial6v4surfacesonthreedimensionallyprintedcustommadeintercalarytibiaprosthesespromisingshorttointermediatetermresults
AT streitburgerarne highlycancelloustitaniumalloytial6v4surfacesonthreedimensionallyprintedcustommadeintercalarytibiaprosthesespromisingshorttointermediatetermresults