Cargando…
Optimization of hemolysis, icterus and lipemia interference thresholds for 35 clinical chemistry assays
OBJECTIVES: Interference of chemistry assays by hemolysis, icterus and lipemia (HIL) was investigated on the Abbott Alinity c system. We sought to empirically establish optimized HIL index thresholds for the purposes of reporting HIL interference in a hospital laboratory and advising clinicians on t...
Autores principales: | Ho, Clement K.M., Chen, Claire, Setoh, Johnson W.S., Yap, Willie W.T., Hawkins, Robert C.W. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8145753/ https://www.ncbi.nlm.nih.gov/pubmed/34095417 http://dx.doi.org/10.1016/j.plabm.2021.e00232 |
Ejemplares similares
-
Hemolysis, icterus and lipemia interfere with the determination of two oxidative stress biomarkers in canine serum
por: Perez-Montero, B., et al.
Publicado: (2023) -
Development of an Integrated Reporting System for Verifying Hemolysis, Icterus, and Lipemia in Clinical Chemistry Results
por: Shin, Dong Hoon, et al.
Publicado: (2014) -
Evaluation of interference effects from hemolysis, icterus and lipemia on the Roche Elecsys® Anti-SARS-CoV-2 assay
por: Tang, Nga-Yeung, et al.
Publicado: (2020) -
The incidence rate and influence factors of hemolysis, lipemia, icterus in fasting serum biochemistry specimens
por: Tian, Gang, et al.
Publicado: (2022) -
Educational Case: Hemolysis and Lipemia Interference With Laboratory Testing
por: Krasowski, Matthew D.
Publicado: (2019)