Cargando…
Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina
Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluate...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8146092/ https://www.ncbi.nlm.nih.gov/pubmed/33924826 http://dx.doi.org/10.3390/genes12050659 |
_version_ | 1783697319923810304 |
---|---|
author | Fellner, María Dolores Bonaventura, Romina Basiletti, Jorge Avaro, Martín Benedetti, Estefanía Campos, Ana Dattero, María Elena Russo, Mara Vladmirsky, Sara Molina, Viviana Irazu, Lucía Rodriguez, Marcelo A. Pontoriero, Andrea Cisterna, Daniel M. Baumeister, Elsa G. |
author_facet | Fellner, María Dolores Bonaventura, Romina Basiletti, Jorge Avaro, Martín Benedetti, Estefanía Campos, Ana Dattero, María Elena Russo, Mara Vladmirsky, Sara Molina, Viviana Irazu, Lucía Rodriguez, Marcelo A. Pontoriero, Andrea Cisterna, Daniel M. Baumeister, Elsa G. |
author_sort | Fellner, María Dolores |
collection | PubMed |
description | Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluated using the World Health Organization (WHO) recommended test as reference method. A secondary standard calibrated for the E, N and RdRp genes against the Pan American Health Organization—World Health Organization—International Standard was used to calculate the limit of detection (LoD). A panel of artificial clinical samples, 32 positive and 30 negative for SARS-CoV-2, were analyzed to estimate the kappa concordance (κ) and the diagnostic performance. Differences among the LoD values for the target genes amplified by each kit were >1 log copies/reaction. The κ for the RT-qPCR kits was greater than 0.9, whereas that for the RT-LAMP assays ranged from 0.75 to 0.93. The clinical performance of RT-qPCR kits showed 100% specificity and high sensitivity, although with variations according to the gene analyzed. The E and N genes provided greater clinical sensitivity, whereas the RdRp gene increased the clinical specificity. The RT-LAMP assays revealed a variable diagnostic performance. The information provided can be useful to choose the most appropriate diagnostic test and may contribute to the establishment of a consensus in the diagnosis of SARS-CoV-2 in Argentina and the region. |
format | Online Article Text |
id | pubmed-8146092 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81460922021-05-26 Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina Fellner, María Dolores Bonaventura, Romina Basiletti, Jorge Avaro, Martín Benedetti, Estefanía Campos, Ana Dattero, María Elena Russo, Mara Vladmirsky, Sara Molina, Viviana Irazu, Lucía Rodriguez, Marcelo A. Pontoriero, Andrea Cisterna, Daniel M. Baumeister, Elsa G. Genes (Basel) Article Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluated using the World Health Organization (WHO) recommended test as reference method. A secondary standard calibrated for the E, N and RdRp genes against the Pan American Health Organization—World Health Organization—International Standard was used to calculate the limit of detection (LoD). A panel of artificial clinical samples, 32 positive and 30 negative for SARS-CoV-2, were analyzed to estimate the kappa concordance (κ) and the diagnostic performance. Differences among the LoD values for the target genes amplified by each kit were >1 log copies/reaction. The κ for the RT-qPCR kits was greater than 0.9, whereas that for the RT-LAMP assays ranged from 0.75 to 0.93. The clinical performance of RT-qPCR kits showed 100% specificity and high sensitivity, although with variations according to the gene analyzed. The E and N genes provided greater clinical sensitivity, whereas the RdRp gene increased the clinical specificity. The RT-LAMP assays revealed a variable diagnostic performance. The information provided can be useful to choose the most appropriate diagnostic test and may contribute to the establishment of a consensus in the diagnosis of SARS-CoV-2 in Argentina and the region. MDPI 2021-04-28 /pmc/articles/PMC8146092/ /pubmed/33924826 http://dx.doi.org/10.3390/genes12050659 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Fellner, María Dolores Bonaventura, Romina Basiletti, Jorge Avaro, Martín Benedetti, Estefanía Campos, Ana Dattero, María Elena Russo, Mara Vladmirsky, Sara Molina, Viviana Irazu, Lucía Rodriguez, Marcelo A. Pontoriero, Andrea Cisterna, Daniel M. Baumeister, Elsa G. Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title | Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title_full | Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title_fullStr | Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title_full_unstemmed | Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title_short | Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina |
title_sort | evaluation of rt-qpcr and loop-mediated isothermal amplification (lamp) assays for the detection of sars-cov-2 in argentina |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8146092/ https://www.ncbi.nlm.nih.gov/pubmed/33924826 http://dx.doi.org/10.3390/genes12050659 |
work_keys_str_mv | AT fellnermariadolores evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT bonaventuraromina evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT basilettijorge evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT avaromartin evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT benedettiestefania evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT camposana evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT datteromariaelena evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT russomara evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT vladmirskysara evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT molinaviviana evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT irazulucia evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT rodriguezmarceloa evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT pontorieroandrea evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT cisternadanielm evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina AT baumeisterelsag evaluationofrtqpcrandloopmediatedisothermalamplificationlampassaysforthedetectionofsarscov2inargentina |