Cargando…

Efficacy of pillar implants to reduce snoring and daytime sleepiness

OBJECTIVE: To measure the efficacy of pillar implants in reducing snoring. MATERIALS AND METHODS: A total of 30 adult patients who underwent pillar implants were assessed preoperatively and at 1, 3, 6 and 12 months after the implantation. Improvement was measured using snoring frequency, visual anal...

Descripción completa

Detalles Bibliográficos
Autores principales: Khasawneh, Laith, Odat, Haitham, Khassawneh, Basheer Y, Kheirallah, Khalid A, Khassawneh, Adi H, Omari, Ahmad Al, Smadi, Maisa, Alzoubi, Firas, Alomari, Safwan, Al-Mistarehi, Abdel-Hameed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Future Science Ltd 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8147739/
https://www.ncbi.nlm.nih.gov/pubmed/34046203
http://dx.doi.org/10.2144/fsoa-2021-0020
_version_ 1783697693316481024
author Khasawneh, Laith
Odat, Haitham
Khassawneh, Basheer Y
Kheirallah, Khalid A
Khassawneh, Adi H
Omari, Ahmad Al
Smadi, Maisa
Alzoubi, Firas
Alomari, Safwan
Al-Mistarehi, Abdel-Hameed
author_facet Khasawneh, Laith
Odat, Haitham
Khassawneh, Basheer Y
Kheirallah, Khalid A
Khassawneh, Adi H
Omari, Ahmad Al
Smadi, Maisa
Alzoubi, Firas
Alomari, Safwan
Al-Mistarehi, Abdel-Hameed
author_sort Khasawneh, Laith
collection PubMed
description OBJECTIVE: To measure the efficacy of pillar implants in reducing snoring. MATERIALS AND METHODS: A total of 30 adult patients who underwent pillar implants were assessed preoperatively and at 1, 3, 6 and 12 months after the implantation. Improvement was measured using snoring frequency, visual analog scale for snoring loudness, and Epworth sleepiness scale for daytime sleepiness. RESULTS: The mean snoring frequency, loudness and Epworth score were reduced from 6.9, 9.2 and 7.4 at the baseline to 5, 5.9 and 5.6, respectively, at 12 months postoperatively (all p < 0.03). The partial implant extrusion rate was 6.7%. CONCLUSION: We suggest that a pillar implant procedure should be considered before proceeding to more morbid surgeries in patients with snoring and daytime sleepiness.
format Online
Article
Text
id pubmed-8147739
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Future Science Ltd
record_format MEDLINE/PubMed
spelling pubmed-81477392021-05-26 Efficacy of pillar implants to reduce snoring and daytime sleepiness Khasawneh, Laith Odat, Haitham Khassawneh, Basheer Y Kheirallah, Khalid A Khassawneh, Adi H Omari, Ahmad Al Smadi, Maisa Alzoubi, Firas Alomari, Safwan Al-Mistarehi, Abdel-Hameed Future Sci OA Research Article OBJECTIVE: To measure the efficacy of pillar implants in reducing snoring. MATERIALS AND METHODS: A total of 30 adult patients who underwent pillar implants were assessed preoperatively and at 1, 3, 6 and 12 months after the implantation. Improvement was measured using snoring frequency, visual analog scale for snoring loudness, and Epworth sleepiness scale for daytime sleepiness. RESULTS: The mean snoring frequency, loudness and Epworth score were reduced from 6.9, 9.2 and 7.4 at the baseline to 5, 5.9 and 5.6, respectively, at 12 months postoperatively (all p < 0.03). The partial implant extrusion rate was 6.7%. CONCLUSION: We suggest that a pillar implant procedure should be considered before proceeding to more morbid surgeries in patients with snoring and daytime sleepiness. Future Science Ltd 2021-03-29 /pmc/articles/PMC8147739/ /pubmed/34046203 http://dx.doi.org/10.2144/fsoa-2021-0020 Text en © 2021 Laith Khasawneh https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/)
spellingShingle Research Article
Khasawneh, Laith
Odat, Haitham
Khassawneh, Basheer Y
Kheirallah, Khalid A
Khassawneh, Adi H
Omari, Ahmad Al
Smadi, Maisa
Alzoubi, Firas
Alomari, Safwan
Al-Mistarehi, Abdel-Hameed
Efficacy of pillar implants to reduce snoring and daytime sleepiness
title Efficacy of pillar implants to reduce snoring and daytime sleepiness
title_full Efficacy of pillar implants to reduce snoring and daytime sleepiness
title_fullStr Efficacy of pillar implants to reduce snoring and daytime sleepiness
title_full_unstemmed Efficacy of pillar implants to reduce snoring and daytime sleepiness
title_short Efficacy of pillar implants to reduce snoring and daytime sleepiness
title_sort efficacy of pillar implants to reduce snoring and daytime sleepiness
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8147739/
https://www.ncbi.nlm.nih.gov/pubmed/34046203
http://dx.doi.org/10.2144/fsoa-2021-0020
work_keys_str_mv AT khasawnehlaith efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT odathaitham efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT khassawnehbasheery efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT kheirallahkhalida efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT khassawnehadih efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT omariahmadal efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT smadimaisa efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT alzoubifiras efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT alomarisafwan efficacyofpillarimplantstoreducesnoringanddaytimesleepiness
AT almistarehiabdelhameed efficacyofpillarimplantstoreducesnoringanddaytimesleepiness