Cargando…

Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults

Accurate prediction of aerobic capacity is necessary to guide appropriate exercise prescription. It is common to use 6-minute walk distance (6MWD) to predict peak oxygen uptake (VO(2peak)) in the clinical environment. The aim of this study was to determine whether prediction of VO(2peak) can be impr...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Fang, Tsang, Raymond C. C., Jones, Alice Y. M., Zhou, Mingchao, Xue, Kaiwen, Chen, Miaoling, Wang, Yulong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8148309/
https://www.ncbi.nlm.nih.gov/pubmed/34032813
http://dx.doi.org/10.1371/journal.pone.0252219
_version_ 1783697808616849408
author Liu, Fang
Tsang, Raymond C. C.
Jones, Alice Y. M.
Zhou, Mingchao
Xue, Kaiwen
Chen, Miaoling
Wang, Yulong
author_facet Liu, Fang
Tsang, Raymond C. C.
Jones, Alice Y. M.
Zhou, Mingchao
Xue, Kaiwen
Chen, Miaoling
Wang, Yulong
author_sort Liu, Fang
collection PubMed
description Accurate prediction of aerobic capacity is necessary to guide appropriate exercise prescription. It is common to use 6-minute walk distance (6MWD) to predict peak oxygen uptake (VO(2peak)) in the clinical environment. The aim of this study was to determine whether prediction of VO(2peak) can be improved by the inclusion of cardiovascular indices derived by impedance cardiography (ICG) during the 6MWT. A total of 62 healthy university students aged 21±1 years completed in separate days, a cardiopulmonary exercise test (CPET) and two 6MWTs (30 min apart), during which heart rate (HR), stroke volume (SV) and cardiac output (CO) were measured by ICG (PhysioFlow(®) PF07 Enduro(TM)). The CPET was conducted with the Ergoselect 200 Ergoline and oxygen consumption measured by a MasterScreen(TM) CPX breath-by-breath metabolic cart. Multiple regression analyses were conducted to generate VO(2peak) prediction equations using 6MWD with, or without the cardiovascular indices recorded at the end of the best performed 6MWT as predictor variables. The mean peak HR (bpm), SV (ml) and CO (L/min) recorded during 6MWT were 156±18, 95.6±9, 15±2.8 and during CPET were 176±16, 91.3±8, 16.2±2.7, respectively. Analyses revealed the following VO(2peak) prediction equation: VO(2peak) = 100.297+(0.019x6MWD)+(-0.598xHR(6MWT))+(-1.236xSV(6MWT)) + (8.671 x CO(6MWT)). This equation has a squared multiple correlation (R(2)) of 0.866, standard error of the estimate (SEE) of 2.28 mL/kg/min and SEE:VO(2peak) (SEE%) of 7.2%. Cross-validation of equation stability using predicted residual sum of squares (PRESS) statistics showed a R(2) (R(p)(2)), SEE (SEE(p)) and SEE(p)% of 0.842, 2.38 mL/kg/min and 7.6% respectively. The minimal shrinkage of R(2) implied regression model stability. Correlation between measured and predicted VO(2peak) using this equation was strong (r = 0.931, p<0.001). When 6MWD alone was used as the predictor for VO(2peak), the generated equation had a lower R(2) (0.549), and a higher SEE (4.08 mL/kg/min) and SEE% (12.9%). This is the first study which included cardiac indices during a 6MWT as variables for VO(2peak) prediction. Our results suggest that inclusion of cardiac indices measured during the 6MWT more accurately predicts VO(2peak) than using 6MWD data alone.
format Online
Article
Text
id pubmed-8148309
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-81483092021-06-07 Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults Liu, Fang Tsang, Raymond C. C. Jones, Alice Y. M. Zhou, Mingchao Xue, Kaiwen Chen, Miaoling Wang, Yulong PLoS One Research Article Accurate prediction of aerobic capacity is necessary to guide appropriate exercise prescription. It is common to use 6-minute walk distance (6MWD) to predict peak oxygen uptake (VO(2peak)) in the clinical environment. The aim of this study was to determine whether prediction of VO(2peak) can be improved by the inclusion of cardiovascular indices derived by impedance cardiography (ICG) during the 6MWT. A total of 62 healthy university students aged 21±1 years completed in separate days, a cardiopulmonary exercise test (CPET) and two 6MWTs (30 min apart), during which heart rate (HR), stroke volume (SV) and cardiac output (CO) were measured by ICG (PhysioFlow(®) PF07 Enduro(TM)). The CPET was conducted with the Ergoselect 200 Ergoline and oxygen consumption measured by a MasterScreen(TM) CPX breath-by-breath metabolic cart. Multiple regression analyses were conducted to generate VO(2peak) prediction equations using 6MWD with, or without the cardiovascular indices recorded at the end of the best performed 6MWT as predictor variables. The mean peak HR (bpm), SV (ml) and CO (L/min) recorded during 6MWT were 156±18, 95.6±9, 15±2.8 and during CPET were 176±16, 91.3±8, 16.2±2.7, respectively. Analyses revealed the following VO(2peak) prediction equation: VO(2peak) = 100.297+(0.019x6MWD)+(-0.598xHR(6MWT))+(-1.236xSV(6MWT)) + (8.671 x CO(6MWT)). This equation has a squared multiple correlation (R(2)) of 0.866, standard error of the estimate (SEE) of 2.28 mL/kg/min and SEE:VO(2peak) (SEE%) of 7.2%. Cross-validation of equation stability using predicted residual sum of squares (PRESS) statistics showed a R(2) (R(p)(2)), SEE (SEE(p)) and SEE(p)% of 0.842, 2.38 mL/kg/min and 7.6% respectively. The minimal shrinkage of R(2) implied regression model stability. Correlation between measured and predicted VO(2peak) using this equation was strong (r = 0.931, p<0.001). When 6MWD alone was used as the predictor for VO(2peak), the generated equation had a lower R(2) (0.549), and a higher SEE (4.08 mL/kg/min) and SEE% (12.9%). This is the first study which included cardiac indices during a 6MWT as variables for VO(2peak) prediction. Our results suggest that inclusion of cardiac indices measured during the 6MWT more accurately predicts VO(2peak) than using 6MWD data alone. Public Library of Science 2021-05-25 /pmc/articles/PMC8148309/ /pubmed/34032813 http://dx.doi.org/10.1371/journal.pone.0252219 Text en © 2021 Liu et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Liu, Fang
Tsang, Raymond C. C.
Jones, Alice Y. M.
Zhou, Mingchao
Xue, Kaiwen
Chen, Miaoling
Wang, Yulong
Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title_full Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title_fullStr Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title_full_unstemmed Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title_short Cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
title_sort cardiodynamic variables measured by impedance cardiography during a 6-minute walk test are reliable predictors of peak oxygen consumption in young healthy adults
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8148309/
https://www.ncbi.nlm.nih.gov/pubmed/34032813
http://dx.doi.org/10.1371/journal.pone.0252219
work_keys_str_mv AT liufang cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT tsangraymondcc cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT jonesaliceym cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT zhoumingchao cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT xuekaiwen cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT chenmiaoling cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults
AT wangyulong cardiodynamicvariablesmeasuredbyimpedancecardiographyduringa6minutewalktestarereliablepredictorsofpeakoxygenconsumptioninyounghealthyadults