Cargando…

Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy

BACKGROUND: The management of hypertensive disorders of pregnancy (HDP) during hospitalization requires an accurate blood pressure (BP) measurement, mainly by invasive intra-arterial reading. Nevertheless, little is known about the precision of non-invasive (NI) central BP measurements in HDP. We ai...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Ayman Khairy M., Shaamash, Ayman H., Mohamed, Asmaa G., Demitry, Salwa R., Razik, Nady A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149773/
https://www.ncbi.nlm.nih.gov/pubmed/34032932
http://dx.doi.org/10.1186/s43044-021-00172-7
_version_ 1783698017493188608
author Hassan, Ayman Khairy M.
Shaamash, Ayman H.
Mohamed, Asmaa G.
Demitry, Salwa R.
Razik, Nady A.
author_facet Hassan, Ayman Khairy M.
Shaamash, Ayman H.
Mohamed, Asmaa G.
Demitry, Salwa R.
Razik, Nady A.
author_sort Hassan, Ayman Khairy M.
collection PubMed
description BACKGROUND: The management of hypertensive disorders of pregnancy (HDP) during hospitalization requires an accurate blood pressure (BP) measurement, mainly by invasive intra-arterial reading. Nevertheless, little is known about the precision of non-invasive (NI) central BP measurements in HDP. We aimed to assess the accuracy of NI central BP assessment in comparison to invasive BP measurement in HDP. This cross-sectional study included all patients with HDP that were admitted to university hospitals for high BP control, from December 2018 till December 2019, and 10 healthy matched non-hypertensive controls. Patients were compared for demographic, anthropometric, and echocardiographic data. In all subjects, invasive BP assessment was done by radial arterial cannulation and NI assessment of BP was performed by an oscillometric automated device (Mobil-O-Graph); the comparison was done after initial control of BP. RESULTS: One hundred patients were included and divided into 3 groups (pre-existing hypertension (HTN), gestational HTN, and pre-eclampsia). There was no statistically significant difference between NI central and invasive methods in measuring both systolic BP (SBP) (126.39 ± 14.5 vs 127.43 ± 15.3, p = 0.5) and diastolic BP (82.41 ± 9.0 vs 83.78 ± 8.9, p = 0.14) among the total studied population. A strong positive correlation was found between NI central and invasive SBP (r = 0.96, p < 0.001). HDP was associated with an increase in arterial stiffness, left ventricular diastolic dysfunction, and complications. CONCLUSION: Non-invasive measurement of BP using oscillometric automated devices is as accurate as the invasive method, and it is a practical safe method in pregnant women with hypertensive disorders (CTR no. = NCT04303871).
format Online
Article
Text
id pubmed-8149773
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-81497732021-06-09 Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy Hassan, Ayman Khairy M. Shaamash, Ayman H. Mohamed, Asmaa G. Demitry, Salwa R. Razik, Nady A. Egypt Heart J Research BACKGROUND: The management of hypertensive disorders of pregnancy (HDP) during hospitalization requires an accurate blood pressure (BP) measurement, mainly by invasive intra-arterial reading. Nevertheless, little is known about the precision of non-invasive (NI) central BP measurements in HDP. We aimed to assess the accuracy of NI central BP assessment in comparison to invasive BP measurement in HDP. This cross-sectional study included all patients with HDP that were admitted to university hospitals for high BP control, from December 2018 till December 2019, and 10 healthy matched non-hypertensive controls. Patients were compared for demographic, anthropometric, and echocardiographic data. In all subjects, invasive BP assessment was done by radial arterial cannulation and NI assessment of BP was performed by an oscillometric automated device (Mobil-O-Graph); the comparison was done after initial control of BP. RESULTS: One hundred patients were included and divided into 3 groups (pre-existing hypertension (HTN), gestational HTN, and pre-eclampsia). There was no statistically significant difference between NI central and invasive methods in measuring both systolic BP (SBP) (126.39 ± 14.5 vs 127.43 ± 15.3, p = 0.5) and diastolic BP (82.41 ± 9.0 vs 83.78 ± 8.9, p = 0.14) among the total studied population. A strong positive correlation was found between NI central and invasive SBP (r = 0.96, p < 0.001). HDP was associated with an increase in arterial stiffness, left ventricular diastolic dysfunction, and complications. CONCLUSION: Non-invasive measurement of BP using oscillometric automated devices is as accurate as the invasive method, and it is a practical safe method in pregnant women with hypertensive disorders (CTR no. = NCT04303871). Springer Berlin Heidelberg 2021-05-25 /pmc/articles/PMC8149773/ /pubmed/34032932 http://dx.doi.org/10.1186/s43044-021-00172-7 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Hassan, Ayman Khairy M.
Shaamash, Ayman H.
Mohamed, Asmaa G.
Demitry, Salwa R.
Razik, Nady A.
Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title_full Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title_fullStr Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title_full_unstemmed Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title_short Comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
title_sort comparison between invasive and non-invasive assessment of blood pressure in hypertensive disorders of pregnancy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149773/
https://www.ncbi.nlm.nih.gov/pubmed/34032932
http://dx.doi.org/10.1186/s43044-021-00172-7
work_keys_str_mv AT hassanaymankhairym comparisonbetweeninvasiveandnoninvasiveassessmentofbloodpressureinhypertensivedisordersofpregnancy
AT shaamashaymanh comparisonbetweeninvasiveandnoninvasiveassessmentofbloodpressureinhypertensivedisordersofpregnancy
AT mohamedasmaag comparisonbetweeninvasiveandnoninvasiveassessmentofbloodpressureinhypertensivedisordersofpregnancy
AT demitrysalwar comparisonbetweeninvasiveandnoninvasiveassessmentofbloodpressureinhypertensivedisordersofpregnancy
AT raziknadya comparisonbetweeninvasiveandnoninvasiveassessmentofbloodpressureinhypertensivedisordersofpregnancy