Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients

PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respira...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Ha Yeon, Ham, Sung-Yeon, Kim, Eun Jung, Yoon, Hei Jin, Choi, Seung Yeon, Koo, Bon-Nyeo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149927/
https://www.ncbi.nlm.nih.gov/pubmed/34027637
http://dx.doi.org/10.3349/ymj.2021.62.6.503
_version_ 1783698053154209792
author Kim, Ha Yeon
Ham, Sung-Yeon
Kim, Eun Jung
Yoon, Hei Jin
Choi, Seung Yeon
Koo, Bon-Nyeo
author_facet Kim, Ha Yeon
Ham, Sung-Yeon
Kim, Eun Jung
Yoon, Hei Jin
Choi, Seung Yeon
Koo, Bon-Nyeo
author_sort Kim, Ha Yeon
collection PubMed
description PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery. MATERIALS AND METHODS: Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4). RESULTS: Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups. CONCLUSION: Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation.
format Online
Article
Text
id pubmed-8149927
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-81499272021-06-05 Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients Kim, Ha Yeon Ham, Sung-Yeon Kim, Eun Jung Yoon, Hei Jin Choi, Seung Yeon Koo, Bon-Nyeo Yonsei Med J Original Article PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery. MATERIALS AND METHODS: Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4). RESULTS: Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups. CONCLUSION: Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation. Yonsei University College of Medicine 2021-06-01 2021-05-14 /pmc/articles/PMC8149927/ /pubmed/34027637 http://dx.doi.org/10.3349/ymj.2021.62.6.503 Text en © Copyright: Yonsei University College of Medicine 2021 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Ha Yeon
Ham, Sung-Yeon
Kim, Eun Jung
Yoon, Hei Jin
Choi, Seung Yeon
Koo, Bon-Nyeo
Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title_full Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title_fullStr Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title_full_unstemmed Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title_short Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
title_sort effect of equal ratio ventilation on respiratory mechanics and oxygenation during volume-controlled ventilation in pediatric patients
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149927/
https://www.ncbi.nlm.nih.gov/pubmed/34027637
http://dx.doi.org/10.3349/ymj.2021.62.6.503
work_keys_str_mv AT kimhayeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients
AT hamsungyeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients
AT kimeunjung effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients
AT yoonheijin effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients
AT choiseungyeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients
AT koobonnyeo effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients