Cargando…
Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients
PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respira...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Yonsei University College of Medicine
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149927/ https://www.ncbi.nlm.nih.gov/pubmed/34027637 http://dx.doi.org/10.3349/ymj.2021.62.6.503 |
_version_ | 1783698053154209792 |
---|---|
author | Kim, Ha Yeon Ham, Sung-Yeon Kim, Eun Jung Yoon, Hei Jin Choi, Seung Yeon Koo, Bon-Nyeo |
author_facet | Kim, Ha Yeon Ham, Sung-Yeon Kim, Eun Jung Yoon, Hei Jin Choi, Seung Yeon Koo, Bon-Nyeo |
author_sort | Kim, Ha Yeon |
collection | PubMed |
description | PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery. MATERIALS AND METHODS: Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4). RESULTS: Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups. CONCLUSION: Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation. |
format | Online Article Text |
id | pubmed-8149927 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Yonsei University College of Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-81499272021-06-05 Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients Kim, Ha Yeon Ham, Sung-Yeon Kim, Eun Jung Yoon, Hei Jin Choi, Seung Yeon Koo, Bon-Nyeo Yonsei Med J Original Article PURPOSE: Children have few small alveoli, which reduce lung compliance; in contrast, their cartilaginous rib cage makes their chest wall highly compliant. This combination promotes lung collapse. Prolonged inspiratory to expiratory (I:E) ratio ventilation is used to optimize gas exchange and respiratory mechanics in surgery. However, the optimal ratio is unclear in children. We hypothesized that, compared to a 1:2 I:E ratio, a 1:1 I:E ratio would improve dynamic compliance and oxygenation, and affect the peak airway pressure in pediatric patients undergoing surgery. MATERIALS AND METHODS: Forty-eight patients aged ≤6 years who were scheduled to undergo surgery under general anesthesia with an arterial line were randomly allocated to receive 1:1 (group 1:1) or 1:2 (group 1:2) I:E ratio ventilation. Airway pressure, respiratory system compliance, and arterial blood gas analyses were compared between groups immediately after induction (T0), 30 min after induction (T1), 60 min after induction (T2), immediately after surgery (T3), and on arrival at the post-anesthesia care unit (T4). RESULTS: Peak and plateau airway pressures were significantly lower in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.048, respectively). The dynamic and static compliances were significantly higher in group 1:1 than in group 1:2 at T1 (p=0.044 and 0.045, respectively). However, the partial pressure of oxygen did not significantly differ between groups. CONCLUSION: Compared to a 1:2 I:E ratio, a 1:1 I:E ratio improved dynamic compliance and lowered the peak airway pressure without complications in pediatric patients. Nevertheless, our results do not support its use solely for improving oxygenation. Yonsei University College of Medicine 2021-06-01 2021-05-14 /pmc/articles/PMC8149927/ /pubmed/34027637 http://dx.doi.org/10.3349/ymj.2021.62.6.503 Text en © Copyright: Yonsei University College of Medicine 2021 https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Ha Yeon Ham, Sung-Yeon Kim, Eun Jung Yoon, Hei Jin Choi, Seung Yeon Koo, Bon-Nyeo Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title | Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title_full | Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title_fullStr | Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title_full_unstemmed | Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title_short | Effect of Equal Ratio Ventilation on Respiratory Mechanics and Oxygenation During Volume-Controlled Ventilation in Pediatric Patients |
title_sort | effect of equal ratio ventilation on respiratory mechanics and oxygenation during volume-controlled ventilation in pediatric patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8149927/ https://www.ncbi.nlm.nih.gov/pubmed/34027637 http://dx.doi.org/10.3349/ymj.2021.62.6.503 |
work_keys_str_mv | AT kimhayeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients AT hamsungyeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients AT kimeunjung effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients AT yoonheijin effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients AT choiseungyeon effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients AT koobonnyeo effectofequalratioventilationonrespiratorymechanicsandoxygenationduringvolumecontrolledventilationinpediatricpatients |