Cargando…
Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans
Functional imaging with (68)Ga prostate-specific membrane antigen (PSMA) and positron emission tomography (PET) can fulfill an important role in treatment selection and adjustment in prostate cancer. This article focusses on quantitative assessment of (68)Ga-PSMA-PET. The effect of various parameter...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8150604/ https://www.ncbi.nlm.nih.gov/pubmed/34066854 http://dx.doi.org/10.3390/diagnostics11050847 |
_version_ | 1783698187793465344 |
---|---|
author | Rijnsdorp, Sjoerd Roef, Mark J. Arends, Albert J. |
author_facet | Rijnsdorp, Sjoerd Roef, Mark J. Arends, Albert J. |
author_sort | Rijnsdorp, Sjoerd |
collection | PubMed |
description | Functional imaging with (68)Ga prostate-specific membrane antigen (PSMA) and positron emission tomography (PET) can fulfill an important role in treatment selection and adjustment in prostate cancer. This article focusses on quantitative assessment of (68)Ga-PSMA-PET. The effect of various parameters on standardized uptake values (SUVs) is explored, and an optimal Bayesian penalized likelihood (BPL) reconstruction is suggested. PET acquisitions of two phantoms consisting of a background compartment and spheres with diameter 4 mm to 37 mm, both filled with solutions of (68)Ga in water, were performed with a GE Discovery 710 PET/CT scanner. Recovery coefficients (RCs) in multiple reconstructions with varying noise penalty factors and acquisition times were determined and analyzed. Apparent recovery coefficients of spheres with a diameter smaller than 17 mm were significantly lower than those of spheres with a diameter of 17 mm and bigger (p < 0.001) for a tumor-to-background (T/B) ratio of 10:1 and a scan time of 10 min per bed position. With a T/B ratio of 10:1, the four largest spheres exhibit significantly higher RCs than those with a T/B ratio of 20:1 (p < 0.0001). For spheres with a diameter of 8 mm and less, alignment with the voxel grid potentially affects the RC. Evaluation of PET/CT scans using (semi-)quantitative measures such as SUVs should be performed with great caution, as SUVs are influenced by scanning and reconstruction parameters. Based on the evaluation of multiple reconstructions with different β of phantom scans, an intermediate β (600) is suggested as the optimal value for the reconstruction of clinical (68)Ga-PSMA PET/CT scans, considering that both detectability and reproducibility are relevant. |
format | Online Article Text |
id | pubmed-8150604 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81506042021-05-27 Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans Rijnsdorp, Sjoerd Roef, Mark J. Arends, Albert J. Diagnostics (Basel) Article Functional imaging with (68)Ga prostate-specific membrane antigen (PSMA) and positron emission tomography (PET) can fulfill an important role in treatment selection and adjustment in prostate cancer. This article focusses on quantitative assessment of (68)Ga-PSMA-PET. The effect of various parameters on standardized uptake values (SUVs) is explored, and an optimal Bayesian penalized likelihood (BPL) reconstruction is suggested. PET acquisitions of two phantoms consisting of a background compartment and spheres with diameter 4 mm to 37 mm, both filled with solutions of (68)Ga in water, were performed with a GE Discovery 710 PET/CT scanner. Recovery coefficients (RCs) in multiple reconstructions with varying noise penalty factors and acquisition times were determined and analyzed. Apparent recovery coefficients of spheres with a diameter smaller than 17 mm were significantly lower than those of spheres with a diameter of 17 mm and bigger (p < 0.001) for a tumor-to-background (T/B) ratio of 10:1 and a scan time of 10 min per bed position. With a T/B ratio of 10:1, the four largest spheres exhibit significantly higher RCs than those with a T/B ratio of 20:1 (p < 0.0001). For spheres with a diameter of 8 mm and less, alignment with the voxel grid potentially affects the RC. Evaluation of PET/CT scans using (semi-)quantitative measures such as SUVs should be performed with great caution, as SUVs are influenced by scanning and reconstruction parameters. Based on the evaluation of multiple reconstructions with different β of phantom scans, an intermediate β (600) is suggested as the optimal value for the reconstruction of clinical (68)Ga-PSMA PET/CT scans, considering that both detectability and reproducibility are relevant. MDPI 2021-05-08 /pmc/articles/PMC8150604/ /pubmed/34066854 http://dx.doi.org/10.3390/diagnostics11050847 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Rijnsdorp, Sjoerd Roef, Mark J. Arends, Albert J. Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title | Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title_full | Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title_fullStr | Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title_full_unstemmed | Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title_short | Impact of the Noise Penalty Factor on Quantification in Bayesian Penalized Likelihood (Q.Clear) Reconstructions of (68)Ga-PSMA PET/CT Scans |
title_sort | impact of the noise penalty factor on quantification in bayesian penalized likelihood (q.clear) reconstructions of (68)ga-psma pet/ct scans |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8150604/ https://www.ncbi.nlm.nih.gov/pubmed/34066854 http://dx.doi.org/10.3390/diagnostics11050847 |
work_keys_str_mv | AT rijnsdorpsjoerd impactofthenoisepenaltyfactoronquantificationinbayesianpenalizedlikelihoodqclearreconstructionsof68gapsmapetctscans AT roefmarkj impactofthenoisepenaltyfactoronquantificationinbayesianpenalizedlikelihoodqclearreconstructionsof68gapsmapetctscans AT arendsalbertj impactofthenoisepenaltyfactoronquantificationinbayesianpenalizedlikelihoodqclearreconstructionsof68gapsmapetctscans |