Cargando…

Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system

BACKGROUND: Hydrogen has advantages that can be used as energy, but research on safe use is needed. OBJECTIVE: In this study, an actuation system for rehabilitation is developed to drive the actuator using hydrogen storage alloy and to analyze the hydrogen release characteristics of the alloy. METHO...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Mi Yeon, Chong, Woo Suk, Yu, Chang Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOS Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8150652/
https://www.ncbi.nlm.nih.gov/pubmed/33682757
http://dx.doi.org/10.3233/THC-218018
_version_ 1783698198893690880
author Shin, Mi Yeon
Chong, Woo Suk
Yu, Chang Ho
author_facet Shin, Mi Yeon
Chong, Woo Suk
Yu, Chang Ho
author_sort Shin, Mi Yeon
collection PubMed
description BACKGROUND: Hydrogen has advantages that can be used as energy, but research on safe use is needed. OBJECTIVE: In this study, an actuation system for rehabilitation is developed to drive the actuator using hydrogen storage alloy and to analyze the hydrogen release characteristics of the alloy. METHODS: The system is automatically control and report the pressure, temperature and hydrogen flow using LabVIEW-based modules and LabVIEW software. Zr [Formula: see text] Ti [Formula: see text] Cr [Formula: see text] Fe [Formula: see text] alloy was selected as hydrogen storage alloy. 5 MPa of hydrogen pressure was applied at 8.56 g of alloy powder for activation process and the temperature outside was maintained at 19 [Formula: see text] C to 21 [Formula: see text] C. The amount of hydrogen absorption was measured about 1.47 wt%. The actuation test was conducted at the temperature from 25 [Formula: see text] C to 80 [Formula: see text] C, increased by every 5 [Formula: see text] C. The actuation height was measured at each load of 5, 10, 15, and 20 kg. The voltage and current which is applied to peltier elements were set to 5.0 V and 2.5 A. The pressure changing in the system was checked for 5 min for each temperature, however, if the temperature at which the pressure inside the system changed, the time to heat the module was increased to 20 min. Hydrogen was first released at 70 [Formula: see text] C. RESULTS: The loads of 5 and 10 kg were raised by 87 and 19 mm at 70 [Formula: see text] C, respectively. At 75 [Formula: see text] C, loads of 5, 10 and 15 kg were raised by 131, 70, and 15 mm, respectively. At 80 [Formula: see text] C, 5, 10, 15, and 20 kg were raised by 150, the end of the actuator, 83, 55, and 28 mm, respectively. CONCLUSIONS: The actuation system in this paper can be applied to assistive device and rehabilitation system for assisting the movement of daily life of the elderly or people with disability.
format Online
Article
Text
id pubmed-8150652
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher IOS Press
record_format MEDLINE/PubMed
spelling pubmed-81506522021-06-09 Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system Shin, Mi Yeon Chong, Woo Suk Yu, Chang Ho Technol Health Care Research Article BACKGROUND: Hydrogen has advantages that can be used as energy, but research on safe use is needed. OBJECTIVE: In this study, an actuation system for rehabilitation is developed to drive the actuator using hydrogen storage alloy and to analyze the hydrogen release characteristics of the alloy. METHODS: The system is automatically control and report the pressure, temperature and hydrogen flow using LabVIEW-based modules and LabVIEW software. Zr [Formula: see text] Ti [Formula: see text] Cr [Formula: see text] Fe [Formula: see text] alloy was selected as hydrogen storage alloy. 5 MPa of hydrogen pressure was applied at 8.56 g of alloy powder for activation process and the temperature outside was maintained at 19 [Formula: see text] C to 21 [Formula: see text] C. The amount of hydrogen absorption was measured about 1.47 wt%. The actuation test was conducted at the temperature from 25 [Formula: see text] C to 80 [Formula: see text] C, increased by every 5 [Formula: see text] C. The actuation height was measured at each load of 5, 10, 15, and 20 kg. The voltage and current which is applied to peltier elements were set to 5.0 V and 2.5 A. The pressure changing in the system was checked for 5 min for each temperature, however, if the temperature at which the pressure inside the system changed, the time to heat the module was increased to 20 min. Hydrogen was first released at 70 [Formula: see text] C. RESULTS: The loads of 5 and 10 kg were raised by 87 and 19 mm at 70 [Formula: see text] C, respectively. At 75 [Formula: see text] C, loads of 5, 10 and 15 kg were raised by 131, 70, and 15 mm, respectively. At 80 [Formula: see text] C, 5, 10, 15, and 20 kg were raised by 150, the end of the actuator, 83, 55, and 28 mm, respectively. CONCLUSIONS: The actuation system in this paper can be applied to assistive device and rehabilitation system for assisting the movement of daily life of the elderly or people with disability. IOS Press 2021-03-25 /pmc/articles/PMC8150652/ /pubmed/33682757 http://dx.doi.org/10.3233/THC-218018 Text en © 2021 – The authors. Published by IOS Press. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial (CC BY-NC 4.0) License (https://creativecommons.org/licenses/by-nc/4.0/) , which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Shin, Mi Yeon
Chong, Woo Suk
Yu, Chang Ho
Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title_full Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title_fullStr Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title_full_unstemmed Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title_short Development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
title_sort development of an actuation system to apply hydrogen storage alloy for the rehabilitative system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8150652/
https://www.ncbi.nlm.nih.gov/pubmed/33682757
http://dx.doi.org/10.3233/THC-218018
work_keys_str_mv AT shinmiyeon developmentofanactuationsystemtoapplyhydrogenstoragealloyfortherehabilitativesystem
AT chongwoosuk developmentofanactuationsystemtoapplyhydrogenstoragealloyfortherehabilitativesystem
AT yuchangho developmentofanactuationsystemtoapplyhydrogenstoragealloyfortherehabilitativesystem