Use of Electrical Impedance Tomography (EIT) to Estimate Tidal Volume in Anaesthetized Horses Undergoing Elective Surgery

SIMPLE SUMMARY: The aim of this study was to explore the usefulness of electrical impedance tomography (EIT), a novel monitoring tool measuring impedance change, to estimate tidal volume (volume of gas in litres moved in and out the airways and lungs with each breath) in anaesthetised horses. The re...

Descripción completa

Detalles Bibliográficos
Autores principales: Crivellari, Benedetta, Raisis, Anthea, Hosgood, Giselle, Waldmann, Andreas D., Murphy, David, Mosing, Martina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8151473/
https://www.ncbi.nlm.nih.gov/pubmed/34068514
http://dx.doi.org/10.3390/ani11051350
Descripción
Sumario:SIMPLE SUMMARY: The aim of this study was to explore the usefulness of electrical impedance tomography (EIT), a novel monitoring tool measuring impedance change, to estimate tidal volume (volume of gas in litres moved in and out the airways and lungs with each breath) in anaesthetised horses. The results of this study, performed in clinical cases, demonstrated that there was a positive linear relationship between tidal volume measurements obtained with spirometry and impedance changes measured by EIT within each subject and this individual relationship could be used to estimate tidal volume that showed acceptable agreement with a measured tidal volume in each horse. Thus, EIT can be used to observe changes in tidal volume by the means of impedance changes. However, absolute measurement of tidal volume is only possible after establishment of the individual relationship. ABSTRACT: This study explores the application of electric impedance tomography (EIT) to estimate tidal volume (VT) by measuring impedance change per breath (∆Z(breath)). Seventeen healthy horses were anaesthetised and mechanically ventilated for elective procedures requiring dorsal recumbency. Spirometric VT (VT(SPIRO)) and ∆Z(breath) were recorded periodically; up to six times throughout anaesthesia. Part 1 assessed these variables at incremental delivered VT of 10, 12 and 15 mL/kg. Part 2 estimated VT (VT(EIT)) in litres from ∆Z(breath) at three additional measurement points using a line of best fit obtained from Part 1. During part 2, VT was adjusted to maintain end-tidal carbon dioxide between 45–55 mmHg. Linear regression determined the correlation between VT(SPIRO) and ∆Z(breath) (part 1). Estimated VT(EIT) was assessed for agreement with measured VT(SPIRO) using Bland Altman analysis (part 2). Marked variability in slope and intercepts was observed across horses. Strong positive correlation between ∆Z(breath) and VT(SPIRO) was found in each horse (R(2) 0.9–0.99). The agreement between VT(EIT) and VT(SPIRO) was good with bias (LOA) of 0.26 (−0.36–0.88) L. These results suggest that, in anaesthetised horses, EIT can be used to monitor and estimate VT after establishing the individual relationship between these variables.