Cargando…

A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study

Purpose To evaluate the accuracy of an augmented reality holographic guidance system for potential use in patient alignment in radiotherapy applications. Methods A cubic phantom was scanned on a CT simulator and a 3D mesh was extracted using the Eclipse Scripting API. An application was created for...

Descripción completa

Detalles Bibliográficos
Autores principales: Cardan, Rex, Covington, Elizabeth L, Popple, Richard
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153089/
https://www.ncbi.nlm.nih.gov/pubmed/34055539
http://dx.doi.org/10.7759/cureus.14695
_version_ 1783698724192518144
author Cardan, Rex
Covington, Elizabeth L
Popple, Richard
author_facet Cardan, Rex
Covington, Elizabeth L
Popple, Richard
author_sort Cardan, Rex
collection PubMed
description Purpose To evaluate the accuracy of an augmented reality holographic guidance system for potential use in patient alignment in radiotherapy applications. Methods A cubic phantom was scanned on a CT simulator and a 3D mesh was extracted using the Eclipse Scripting API. An application was created for the Microsoft HoloLens to allow users to see the scanned mesh as a hologram overlaid in the treatment vault. Six therapists were equipped with the HoloLens glasses and instructed to move the real phantom to align with the perceived spatial hologram using only couch controls. The initial couch coordinates were recorded and then recorded at each step as the therapist moved the phantom to each new location. The application varied the position of the virtual phantom to 10 preprogrammed locations within a 40-cm cubic volume in a combination of vertical, longitudinal, and lateral axis shifts. The absolute position difference between the holographic world and real-world phantom was recorded at each step. Also, the relative position from one position to the next was recorded. Results Fifty shifts were collected across the six therapists. The mean difference between the physical position and instructed holographic position was 0.58 ± 0.31 cm for relative shifts and 0.51 ± 0.33 cm for absolute position. The maximum difference between the holographic position and the actual post shift position was 1.53 cm for relative and 1.58 cm for absolute. Conclusion Holographic augmented reality guidance using the Microsoft HoloLens provides adequate accuracy for initial treatment alignment but lacks the fine alignment accuracy of X-ray imaging systems.
format Online
Article
Text
id pubmed-8153089
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-81530892021-05-27 A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study Cardan, Rex Covington, Elizabeth L Popple, Richard Cureus Medical Physics Purpose To evaluate the accuracy of an augmented reality holographic guidance system for potential use in patient alignment in radiotherapy applications. Methods A cubic phantom was scanned on a CT simulator and a 3D mesh was extracted using the Eclipse Scripting API. An application was created for the Microsoft HoloLens to allow users to see the scanned mesh as a hologram overlaid in the treatment vault. Six therapists were equipped with the HoloLens glasses and instructed to move the real phantom to align with the perceived spatial hologram using only couch controls. The initial couch coordinates were recorded and then recorded at each step as the therapist moved the phantom to each new location. The application varied the position of the virtual phantom to 10 preprogrammed locations within a 40-cm cubic volume in a combination of vertical, longitudinal, and lateral axis shifts. The absolute position difference between the holographic world and real-world phantom was recorded at each step. Also, the relative position from one position to the next was recorded. Results Fifty shifts were collected across the six therapists. The mean difference between the physical position and instructed holographic position was 0.58 ± 0.31 cm for relative shifts and 0.51 ± 0.33 cm for absolute position. The maximum difference between the holographic position and the actual post shift position was 1.53 cm for relative and 1.58 cm for absolute. Conclusion Holographic augmented reality guidance using the Microsoft HoloLens provides adequate accuracy for initial treatment alignment but lacks the fine alignment accuracy of X-ray imaging systems. Cureus 2021-04-26 /pmc/articles/PMC8153089/ /pubmed/34055539 http://dx.doi.org/10.7759/cureus.14695 Text en Copyright © 2021, Cardan et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Medical Physics
Cardan, Rex
Covington, Elizabeth L
Popple, Richard
A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title_full A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title_fullStr A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title_full_unstemmed A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title_short A Holographic Augmented Reality Guidance System for Patient Alignment: A Feasibility Study
title_sort holographic augmented reality guidance system for patient alignment: a feasibility study
topic Medical Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153089/
https://www.ncbi.nlm.nih.gov/pubmed/34055539
http://dx.doi.org/10.7759/cureus.14695
work_keys_str_mv AT cardanrex aholographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy
AT covingtonelizabethl aholographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy
AT popplerichard aholographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy
AT cardanrex holographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy
AT covingtonelizabethl holographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy
AT popplerichard holographicaugmentedrealityguidancesystemforpatientalignmentafeasibilitystudy