Cargando…

Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device

The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal...

Descripción completa

Detalles Bibliográficos
Autores principales: Raharja, Antony, Leo, Shaun M., Chow, Isabelle, Indusegaran, Mathura, Hammond, Christopher J., Mahroo, Omar A., Wong, Sui H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153331/
https://www.ncbi.nlm.nih.gov/pubmed/34068365
http://dx.doi.org/10.3390/life11050437
_version_ 1783698777554550784
author Raharja, Antony
Leo, Shaun M.
Chow, Isabelle
Indusegaran, Mathura
Hammond, Christopher J.
Mahroo, Omar A.
Wong, Sui H.
author_facet Raharja, Antony
Leo, Shaun M.
Chow, Isabelle
Indusegaran, Mathura
Hammond, Christopher J.
Mahroo, Omar A.
Wong, Sui H.
author_sort Raharja, Antony
collection PubMed
description The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal electroretinography. This study explored the use of a handheld device (RETeval, LKC technologies, Gaithersburg, MD, USA) in 72 IIH patients of varying stages and severity (and seven controls) and investigated associations between PhNR parameters and disease severity. PhNR amplitudes at 72 ms (P(72)) and p-ratio (ratio to b-wave peak value) differed significantly across groups, with a trend towards smaller amplitudes in those with severe IIH, defined as papilloedema with Modified Frisén Scale (MFS) ≥ 3, retinal nerve fibre layer (RNFL) ≥ 150 μm or atrophic papilloedema (p = 0.0048 and p = 0.018 for P72 and p-ratio, respectively). PhNR parameters did not correlate with MFS, RNFL thickness, standard automated perimetry mean deviation or macular ganglion cell layer volume. This study suggests that PhNR measurement using a handheld device is feasible and could potentially augment the assessment of disease severity in IIH. The clinical utility of PhNR monitoring in IIH patients requires further investigation.
format Online
Article
Text
id pubmed-8153331
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81533312021-05-27 Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device Raharja, Antony Leo, Shaun M. Chow, Isabelle Indusegaran, Mathura Hammond, Christopher J. Mahroo, Omar A. Wong, Sui H. Life (Basel) Article The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal electroretinography. This study explored the use of a handheld device (RETeval, LKC technologies, Gaithersburg, MD, USA) in 72 IIH patients of varying stages and severity (and seven controls) and investigated associations between PhNR parameters and disease severity. PhNR amplitudes at 72 ms (P(72)) and p-ratio (ratio to b-wave peak value) differed significantly across groups, with a trend towards smaller amplitudes in those with severe IIH, defined as papilloedema with Modified Frisén Scale (MFS) ≥ 3, retinal nerve fibre layer (RNFL) ≥ 150 μm or atrophic papilloedema (p = 0.0048 and p = 0.018 for P72 and p-ratio, respectively). PhNR parameters did not correlate with MFS, RNFL thickness, standard automated perimetry mean deviation or macular ganglion cell layer volume. This study suggests that PhNR measurement using a handheld device is feasible and could potentially augment the assessment of disease severity in IIH. The clinical utility of PhNR monitoring in IIH patients requires further investigation. MDPI 2021-05-13 /pmc/articles/PMC8153331/ /pubmed/34068365 http://dx.doi.org/10.3390/life11050437 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Raharja, Antony
Leo, Shaun M.
Chow, Isabelle
Indusegaran, Mathura
Hammond, Christopher J.
Mahroo, Omar A.
Wong, Sui H.
Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title_full Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title_fullStr Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title_full_unstemmed Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title_short Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
title_sort exploratory study of the association between the severity of idiopathic intracranial hypertension and electroretinogram photopic negative response amplitude obtained using a handheld device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153331/
https://www.ncbi.nlm.nih.gov/pubmed/34068365
http://dx.doi.org/10.3390/life11050437
work_keys_str_mv AT raharjaantony exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT leoshaunm exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT chowisabelle exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT indusegaranmathura exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT hammondchristopherj exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT mahrooomara exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice
AT wongsuih exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice