Cargando…
Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device
The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153331/ https://www.ncbi.nlm.nih.gov/pubmed/34068365 http://dx.doi.org/10.3390/life11050437 |
_version_ | 1783698777554550784 |
---|---|
author | Raharja, Antony Leo, Shaun M. Chow, Isabelle Indusegaran, Mathura Hammond, Christopher J. Mahroo, Omar A. Wong, Sui H. |
author_facet | Raharja, Antony Leo, Shaun M. Chow, Isabelle Indusegaran, Mathura Hammond, Christopher J. Mahroo, Omar A. Wong, Sui H. |
author_sort | Raharja, Antony |
collection | PubMed |
description | The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal electroretinography. This study explored the use of a handheld device (RETeval, LKC technologies, Gaithersburg, MD, USA) in 72 IIH patients of varying stages and severity (and seven controls) and investigated associations between PhNR parameters and disease severity. PhNR amplitudes at 72 ms (P(72)) and p-ratio (ratio to b-wave peak value) differed significantly across groups, with a trend towards smaller amplitudes in those with severe IIH, defined as papilloedema with Modified Frisén Scale (MFS) ≥ 3, retinal nerve fibre layer (RNFL) ≥ 150 μm or atrophic papilloedema (p = 0.0048 and p = 0.018 for P72 and p-ratio, respectively). PhNR parameters did not correlate with MFS, RNFL thickness, standard automated perimetry mean deviation or macular ganglion cell layer volume. This study suggests that PhNR measurement using a handheld device is feasible and could potentially augment the assessment of disease severity in IIH. The clinical utility of PhNR monitoring in IIH patients requires further investigation. |
format | Online Article Text |
id | pubmed-8153331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-81533312021-05-27 Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device Raharja, Antony Leo, Shaun M. Chow, Isabelle Indusegaran, Mathura Hammond, Christopher J. Mahroo, Omar A. Wong, Sui H. Life (Basel) Article The photopic negative response (PhNR) is a negative component of the photopic flash electroretinogram that follows the b-wave and is thought to arise from the retinal ganglion cells. Reduction in its amplitude in idiopathic intracranial hypertension (IIH) has been previously documented using formal electroretinography. This study explored the use of a handheld device (RETeval, LKC technologies, Gaithersburg, MD, USA) in 72 IIH patients of varying stages and severity (and seven controls) and investigated associations between PhNR parameters and disease severity. PhNR amplitudes at 72 ms (P(72)) and p-ratio (ratio to b-wave peak value) differed significantly across groups, with a trend towards smaller amplitudes in those with severe IIH, defined as papilloedema with Modified Frisén Scale (MFS) ≥ 3, retinal nerve fibre layer (RNFL) ≥ 150 μm or atrophic papilloedema (p = 0.0048 and p = 0.018 for P72 and p-ratio, respectively). PhNR parameters did not correlate with MFS, RNFL thickness, standard automated perimetry mean deviation or macular ganglion cell layer volume. This study suggests that PhNR measurement using a handheld device is feasible and could potentially augment the assessment of disease severity in IIH. The clinical utility of PhNR monitoring in IIH patients requires further investigation. MDPI 2021-05-13 /pmc/articles/PMC8153331/ /pubmed/34068365 http://dx.doi.org/10.3390/life11050437 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Raharja, Antony Leo, Shaun M. Chow, Isabelle Indusegaran, Mathura Hammond, Christopher J. Mahroo, Omar A. Wong, Sui H. Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title | Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title_full | Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title_fullStr | Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title_full_unstemmed | Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title_short | Exploratory Study of the Association between the Severity of Idiopathic Intracranial Hypertension and Electroretinogram Photopic Negative Response Amplitude Obtained Using a Handheld Device |
title_sort | exploratory study of the association between the severity of idiopathic intracranial hypertension and electroretinogram photopic negative response amplitude obtained using a handheld device |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153331/ https://www.ncbi.nlm.nih.gov/pubmed/34068365 http://dx.doi.org/10.3390/life11050437 |
work_keys_str_mv | AT raharjaantony exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT leoshaunm exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT chowisabelle exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT indusegaranmathura exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT hammondchristopherj exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT mahrooomara exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice AT wongsuih exploratorystudyoftheassociationbetweentheseverityofidiopathicintracranialhypertensionandelectroretinogramphotopicnegativeresponseamplitudeobtainedusingahandhelddevice |