Cargando…
Advanced muon radiography with compact accelerator system
By using a well-defined mono-energetic, pencil-like, high-energy and intense muon beam, one can realize, via simultaneous measurements of energy-loss and multiple-scattering, a quick and element-selective radiography to detect e.g. a few kg of U which is shielded in a thick Fe container or hidden wi...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japan Academy
2004
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153360/ |
Sumario: | By using a well-defined mono-energetic, pencil-like, high-energy and intense muon beam, one can realize, via simultaneous measurements of energy-loss and multiple-scattering, a quick and element-selective radiography to detect e.g. a few kg of U which is shielded in a thick Fe container or hidden within 2–3 m of low-Z material. A source of such an ideal beam of muons can be realized in transportable form via truck trailers, by combining a compact 400 MeV electron accelerator for photo π/μ production, a superconducting solenoid for full-solid-angle π/μ capture and transport, a stopping in hot tungsten metal for cooling of energetic μ(+) to sub-eV μ(+), and finally a compact linear accelerator for rapid acceleration to 600 MeV. Principle and some details are described. |
---|