Cargando…

P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?

INTRODUCTION: A survey completed by junior doctors who routinely run eye casualty clinics identified Goldmann applanation tonometry (GAT) as the single most time-consuming element of a standard consultation. IOP can be measured with a range of devices in the eye clinic. By identifying the most accur...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Chanelle, Mamtora, Sunil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153816/
http://dx.doi.org/10.1093/bjsopen/zrab032.068
_version_ 1783698881008107520
author Smith, Chanelle
Mamtora, Sunil
author_facet Smith, Chanelle
Mamtora, Sunil
author_sort Smith, Chanelle
collection PubMed
description INTRODUCTION: A survey completed by junior doctors who routinely run eye casualty clinics identified Goldmann applanation tonometry (GAT) as the single most time-consuming element of a standard consultation. IOP can be measured with a range of devices in the eye clinic. By identifying the most accurate and time efficient method we can save time in consultations as well as provide better outcomes for the patient. PURPOSE: To compare four tonometry techniques: Goldmann applanation tonometer(GAT), Non-contact tonometer(NCT), Tonopen(TP) and Icare tonometer(ICT) to determine the most accurate and efficient method. METHOD: 20 subjects presenting in the casualty eye clinic were used in the study ranging between 36-75 years. Once undergoing routine ophthalmic examination from the same clinician, IOP was recorded with all devices. Three readings were taken before calculating an average value and time taken for each device for each patient. No patients were excluded from the study. RESULTS: The average IOP with GAT, NCT, TP and ICT was 8.5 ± 2.7, 10.3 ± 4.2, 8.6 ± 3.1, and 8.4 ± 4.5 mmHg, respectively. The average time taken with GAT, NCT, TP and ICT was 56, 132, 38 and 23 seconds, respectively. There was no significant difference in IOP measured by GAT and TP and ICT however, NCT (10.3 mm Hg, P < 0.01) measured significantly higher IOPs compared to GAT. CONCLUSION: When compared to Goldmann applanation tonometer, Icare was the most accurate and efficient method. While Tonopen was fairly accurate some patients were unable to tolerate it. NCT was significantly slower compared to other devices.
format Online
Article
Text
id pubmed-8153816
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-81538162021-05-28 P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All? Smith, Chanelle Mamtora, Sunil BJS Open Poster Presentation INTRODUCTION: A survey completed by junior doctors who routinely run eye casualty clinics identified Goldmann applanation tonometry (GAT) as the single most time-consuming element of a standard consultation. IOP can be measured with a range of devices in the eye clinic. By identifying the most accurate and time efficient method we can save time in consultations as well as provide better outcomes for the patient. PURPOSE: To compare four tonometry techniques: Goldmann applanation tonometer(GAT), Non-contact tonometer(NCT), Tonopen(TP) and Icare tonometer(ICT) to determine the most accurate and efficient method. METHOD: 20 subjects presenting in the casualty eye clinic were used in the study ranging between 36-75 years. Once undergoing routine ophthalmic examination from the same clinician, IOP was recorded with all devices. Three readings were taken before calculating an average value and time taken for each device for each patient. No patients were excluded from the study. RESULTS: The average IOP with GAT, NCT, TP and ICT was 8.5 ± 2.7, 10.3 ± 4.2, 8.6 ± 3.1, and 8.4 ± 4.5 mmHg, respectively. The average time taken with GAT, NCT, TP and ICT was 56, 132, 38 and 23 seconds, respectively. There was no significant difference in IOP measured by GAT and TP and ICT however, NCT (10.3 mm Hg, P < 0.01) measured significantly higher IOPs compared to GAT. CONCLUSION: When compared to Goldmann applanation tonometer, Icare was the most accurate and efficient method. While Tonopen was fairly accurate some patients were unable to tolerate it. NCT was significantly slower compared to other devices. Oxford University Press 2021-04-08 /pmc/articles/PMC8153816/ http://dx.doi.org/10.1093/bjsopen/zrab032.068 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of BJS Society Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercialre-use, please contact journals.permissions@oup.com
spellingShingle Poster Presentation
Smith, Chanelle
Mamtora, Sunil
P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title_full P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title_fullStr P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title_full_unstemmed P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title_short P69 Intra-ocular pressure measurement in eye casualty: Which is the Fairest of Them All?
title_sort p69 intra-ocular pressure measurement in eye casualty: which is the fairest of them all?
topic Poster Presentation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8153816/
http://dx.doi.org/10.1093/bjsopen/zrab032.068
work_keys_str_mv AT smithchanelle p69intraocularpressuremeasurementineyecasualtywhichisthefairestofthemall
AT mamtorasunil p69intraocularpressuremeasurementineyecasualtywhichisthefairestofthemall