Cargando…
Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
[Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible s...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2021
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154029/ https://www.ncbi.nlm.nih.gov/pubmed/34056312 http://dx.doi.org/10.1021/acsomega.1c00773 |
_version_ | 1783698928795910144 |
---|---|
author | Verrinder, Elsi Wester, Niklas Leppänen, Elli Lilius, Tuomas Kalso, Eija Mikladal, Bjo̷rn Varjos, Ilkka Koskinen, Jari Laurila, Tomi |
author_facet | Verrinder, Elsi Wester, Niklas Leppänen, Elli Lilius, Tuomas Kalso, Eija Mikladal, Bjo̷rn Varjos, Ilkka Koskinen, Jari Laurila, Tomi |
author_sort | Verrinder, Elsi |
collection | PubMed |
description | [Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5–10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood. |
format | Online Article Text |
id | pubmed-8154029 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-81540292021-05-27 Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood Verrinder, Elsi Wester, Niklas Leppänen, Elli Lilius, Tuomas Kalso, Eija Mikladal, Bjo̷rn Varjos, Ilkka Koskinen, Jari Laurila, Tomi ACS Omega [Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5–10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood. American Chemical Society 2021-04-21 /pmc/articles/PMC8154029/ /pubmed/34056312 http://dx.doi.org/10.1021/acsomega.1c00773 Text en © 2021 The Authors. Published by American Chemical Society Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Verrinder, Elsi Wester, Niklas Leppänen, Elli Lilius, Tuomas Kalso, Eija Mikladal, Bjo̷rn Varjos, Ilkka Koskinen, Jari Laurila, Tomi Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood |
title | Electrochemical Detection of Morphine in Untreated
Human Capillary Whole Blood |
title_full | Electrochemical Detection of Morphine in Untreated
Human Capillary Whole Blood |
title_fullStr | Electrochemical Detection of Morphine in Untreated
Human Capillary Whole Blood |
title_full_unstemmed | Electrochemical Detection of Morphine in Untreated
Human Capillary Whole Blood |
title_short | Electrochemical Detection of Morphine in Untreated
Human Capillary Whole Blood |
title_sort | electrochemical detection of morphine in untreated
human capillary whole blood |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154029/ https://www.ncbi.nlm.nih.gov/pubmed/34056312 http://dx.doi.org/10.1021/acsomega.1c00773 |
work_keys_str_mv | AT verrinderelsi electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT westerniklas electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT leppanenelli electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT liliustuomas electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT kalsoeija electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT mikladalbjorn electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT varjosilkka electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT koskinenjari electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood AT laurilatomi electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood |