Cargando…

Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood

[Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible s...

Descripción completa

Detalles Bibliográficos
Autores principales: Verrinder, Elsi, Wester, Niklas, Leppänen, Elli, Lilius, Tuomas, Kalso, Eija, Mikladal, Bjo̷rn, Varjos, Ilkka, Koskinen, Jari, Laurila, Tomi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154029/
https://www.ncbi.nlm.nih.gov/pubmed/34056312
http://dx.doi.org/10.1021/acsomega.1c00773
_version_ 1783698928795910144
author Verrinder, Elsi
Wester, Niklas
Leppänen, Elli
Lilius, Tuomas
Kalso, Eija
Mikladal, Bjo̷rn
Varjos, Ilkka
Koskinen, Jari
Laurila, Tomi
author_facet Verrinder, Elsi
Wester, Niklas
Leppänen, Elli
Lilius, Tuomas
Kalso, Eija
Mikladal, Bjo̷rn
Varjos, Ilkka
Koskinen, Jari
Laurila, Tomi
author_sort Verrinder, Elsi
collection PubMed
description [Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5–10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood.
format Online
Article
Text
id pubmed-8154029
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-81540292021-05-27 Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood Verrinder, Elsi Wester, Niklas Leppänen, Elli Lilius, Tuomas Kalso, Eija Mikladal, Bjo̷rn Varjos, Ilkka Koskinen, Jari Laurila, Tomi ACS Omega [Image: see text] Disposable single-use electrochemical sensor strips were used for quantitative detection of small concentrations of morphine in untreated capillary whole blood. Single-walled carbon nanotube (SWCNT) networks were fabricated on a polymer substrate to produce flexible, reproducible sensor strips with integrated reference and counter electrodes, compatible with industrial-scale processes. A thin Nafion coating was used on top of the sensors to enable direct electrochemical detection in whole blood. These sensors were shown to detect clinically relevant concentrations of morphine both in buffer and in whole blood samples. Small 38 μL finger-prick blood samples were spiked with 2 μL of morphine solution of several concentrations and measured without precipitation of proteins or any other further pretreatment. A linear range of 0.5–10 μM was achieved in both matrices and a detection limit of 0.48 μM in buffer. In addition, to demonstrate the applicability of the sensor in a point-of-care device, single-determination measurements were done with capillary samples from three subjects. An average recovery of 60% was found, suggesting that the sensor only measures the free, unbound fraction of the drug. An interference study with other opioids and possible interferents showed the selectivity of the sensor. This study clearly indicates that these Nafion/SWCNT sensor strips show great promise as a point-of-care rapid test for morphine in blood. American Chemical Society 2021-04-21 /pmc/articles/PMC8154029/ /pubmed/34056312 http://dx.doi.org/10.1021/acsomega.1c00773 Text en © 2021 The Authors. Published by American Chemical Society Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Verrinder, Elsi
Wester, Niklas
Leppänen, Elli
Lilius, Tuomas
Kalso, Eija
Mikladal, Bjo̷rn
Varjos, Ilkka
Koskinen, Jari
Laurila, Tomi
Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title_full Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title_fullStr Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title_full_unstemmed Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title_short Electrochemical Detection of Morphine in Untreated Human Capillary Whole Blood
title_sort electrochemical detection of morphine in untreated human capillary whole blood
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154029/
https://www.ncbi.nlm.nih.gov/pubmed/34056312
http://dx.doi.org/10.1021/acsomega.1c00773
work_keys_str_mv AT verrinderelsi electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT westerniklas electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT leppanenelli electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT liliustuomas electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT kalsoeija electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT mikladalbjorn electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT varjosilkka electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT koskinenjari electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood
AT laurilatomi electrochemicaldetectionofmorphineinuntreatedhumancapillarywholeblood