Cargando…
Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment
To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively exami...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154376/ https://www.ncbi.nlm.nih.gov/pubmed/34032704 http://dx.doi.org/10.1097/MD.0000000000025947 |
_version_ | 1783698999858954240 |
---|---|
author | Ruby, Lisa Sanabria, Sergio J. Saltybaeva, Natalia Frauenfelder, Thomas Alkadhi, Hatem Rominger, Marga B. |
author_facet | Ruby, Lisa Sanabria, Sergio J. Saltybaeva, Natalia Frauenfelder, Thomas Alkadhi, Hatem Rominger, Marga B. |
author_sort | Ruby, Lisa |
collection | PubMed |
description | To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively examined with ultrasound. A plexiglas-reflector located on the opposite side of the probe with the calf in between was used as a timing reference for SoS (m/s). CT measurements were performed at the level of L3 and included area (cm(2)) and attenuation (HU) of the psoas muscle, abdominal muscles, subcutaneous fat, visceral fat and abdominal area. Correlations between SoS, body mass index (BMI) and CT were determined using Pearson's correlation coefficient. Based on reported CT sarcopenia threshold values, receiver operating characteristic (ROC) analysis was performed for SoS. Inter-examiner agreement was assessed with the median difference, inter-quartile range (IQR) and intraclass correlation coefficients. SoS of the calf correlated moderately with abdominal muscle attenuation (r = 0.48; P < .001), psoas muscle attenuation (r = 0.40; P < .01), abdominal area (r = −0.44; P < .01) and weakly with subcutaneous fat area (r = −0.37; P < .01). BMI correlated weakly with psoas attenuation (r = −0.28; P < .05) and non-significantly with abdominal muscle attenuation. Normalization with abdominal area resulted in moderate correlations with abdominal muscle area for SoS (r = 0.43; P < .01) and BMI (r = −0.46; P < .001). Based on sarcopenia threshold values for skeletal muscle attenuation (SMRA), area under curve (AUC) for SoS was 0.724. Median difference between both examiners was −3.4 m/s with IQR = 15.1 m/s and intraclass correlation coefficient = 0.794. SoS measurements of the calf are moderately accurate based on CT sarcopenia threshold values, thus showing potential for muscle loss quantification. |
format | Online Article Text |
id | pubmed-8154376 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Lippincott Williams & Wilkins |
record_format | MEDLINE/PubMed |
spelling | pubmed-81543762021-05-29 Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment Ruby, Lisa Sanabria, Sergio J. Saltybaeva, Natalia Frauenfelder, Thomas Alkadhi, Hatem Rominger, Marga B. Medicine (Baltimore) 6800 To compare the speed of propagation of ultrasound (US) waves (SoS) of the lower leg with the clinical reference standard computed tomography (CT) at the level of lumbar vertebra 3 (L3) for muscle loss assessment. Both calf muscles of 50 patients scheduled for an abdominal CT were prospectively examined with ultrasound. A plexiglas-reflector located on the opposite side of the probe with the calf in between was used as a timing reference for SoS (m/s). CT measurements were performed at the level of L3 and included area (cm(2)) and attenuation (HU) of the psoas muscle, abdominal muscles, subcutaneous fat, visceral fat and abdominal area. Correlations between SoS, body mass index (BMI) and CT were determined using Pearson's correlation coefficient. Based on reported CT sarcopenia threshold values, receiver operating characteristic (ROC) analysis was performed for SoS. Inter-examiner agreement was assessed with the median difference, inter-quartile range (IQR) and intraclass correlation coefficients. SoS of the calf correlated moderately with abdominal muscle attenuation (r = 0.48; P < .001), psoas muscle attenuation (r = 0.40; P < .01), abdominal area (r = −0.44; P < .01) and weakly with subcutaneous fat area (r = −0.37; P < .01). BMI correlated weakly with psoas attenuation (r = −0.28; P < .05) and non-significantly with abdominal muscle attenuation. Normalization with abdominal area resulted in moderate correlations with abdominal muscle area for SoS (r = 0.43; P < .01) and BMI (r = −0.46; P < .001). Based on sarcopenia threshold values for skeletal muscle attenuation (SMRA), area under curve (AUC) for SoS was 0.724. Median difference between both examiners was −3.4 m/s with IQR = 15.1 m/s and intraclass correlation coefficient = 0.794. SoS measurements of the calf are moderately accurate based on CT sarcopenia threshold values, thus showing potential for muscle loss quantification. Lippincott Williams & Wilkins 2021-05-28 /pmc/articles/PMC8154376/ /pubmed/34032704 http://dx.doi.org/10.1097/MD.0000000000025947 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) |
spellingShingle | 6800 Ruby, Lisa Sanabria, Sergio J. Saltybaeva, Natalia Frauenfelder, Thomas Alkadhi, Hatem Rominger, Marga B. Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title | Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title_full | Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title_fullStr | Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title_full_unstemmed | Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title_short | Comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
title_sort | comparison of ultrasound speed-of-sound of the lower extremity and lumbar muscle assessed with computed tomography for muscle loss assessment |
topic | 6800 |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154376/ https://www.ncbi.nlm.nih.gov/pubmed/34032704 http://dx.doi.org/10.1097/MD.0000000000025947 |
work_keys_str_mv | AT rubylisa comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment AT sanabriasergioj comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment AT saltybaevanatalia comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment AT frauenfelderthomas comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment AT alkadhihatem comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment AT romingermargab comparisonofultrasoundspeedofsoundofthelowerextremityandlumbarmuscleassessedwithcomputedtomographyformusclelossassessment |