Cargando…

Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report

RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for re...

Descripción completa

Detalles Bibliográficos
Autores principales: Blessberger, Hermann, Kellermair, Joerg, Kammler, Juergen, Steinwender, Clemens, Zierer, Andreas F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154387/
https://www.ncbi.nlm.nih.gov/pubmed/34032769
http://dx.doi.org/10.1097/MD.0000000000026148
_version_ 1783699002542260224
author Blessberger, Hermann
Kellermair, Joerg
Kammler, Juergen
Steinwender, Clemens
Zierer, Andreas F.
author_facet Blessberger, Hermann
Kellermair, Joerg
Kammler, Juergen
Steinwender, Clemens
Zierer, Andreas F.
author_sort Blessberger, Hermann
collection PubMed
description RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS: We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P(2))/segment 3 of the posterior mitral valve leaflet (P(3)) 4 years before. DIAGNOSES: Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS: After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES: The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS: As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass.
format Online
Article
Text
id pubmed-8154387
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-81543872021-05-29 Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report Blessberger, Hermann Kellermair, Joerg Kammler, Juergen Steinwender, Clemens Zierer, Andreas F. Medicine (Baltimore) 3400 RATIONALE: Redo surgeries after mitral valve repair are technically demanding. Procedures applying the NeoChord device (NeoChord Inc, St. Louis Park, MN) have proven to be safe and feasible in selected patients requiring mitral valve repair due to a leaflet prolapse or flail. However, its use for redo procedures after conventional surgical repair has not been well established yet. PATIENT CONCERNS: We report the case of a 57-year-old man who presented with dyspnea upon exertion. The patient had undergone a minimally invasive surgical mitral valve repair because of a flail leaflet of the segments segment 2 of the posterior mitral valve leaflet (P(2))/segment 3 of the posterior mitral valve leaflet (P(3)) 4 years before. DIAGNOSES: Transesophageal echocardiography identified a relapse of severe mitral valve regurgitation. The recurring regurgitant jet was caused by a flail leaflet due to newly ruptured native chords. INTERVENTIONS: After discussion in an interdisciplinary heart team, we performed a minimally invasive off-pump redo procedure applying the NeoChord device under three-dimensional transesophageal echocardiographic guidance. OUTCOMES: The echocardiographic result with only trivial residual mitral regurgitation as well as the further clinical course of the patient were favorable. LESSONS: As redo surgery after minimally invasive mitral valve repair is challenging, the NeoChord device represents a novel treatment option that does not require cardiopulmonary bypass. Lippincott Williams & Wilkins 2021-05-28 /pmc/articles/PMC8154387/ /pubmed/34032769 http://dx.doi.org/10.1097/MD.0000000000026148 Text en Copyright © 2021 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. http://creativecommons.org/licenses/by/4.0 (https://creativecommons.org/licenses/by/4.0/)
spellingShingle 3400
Blessberger, Hermann
Kellermair, Joerg
Kammler, Juergen
Steinwender, Clemens
Zierer, Andreas F.
Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title_full Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title_fullStr Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title_full_unstemmed Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title_short Transapical off-pump mitral valve repair following prior mitral valve surgery: A case report
title_sort transapical off-pump mitral valve repair following prior mitral valve surgery: a case report
topic 3400
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154387/
https://www.ncbi.nlm.nih.gov/pubmed/34032769
http://dx.doi.org/10.1097/MD.0000000000026148
work_keys_str_mv AT blessbergerhermann transapicaloffpumpmitralvalverepairfollowingpriormitralvalvesurgeryacasereport
AT kellermairjoerg transapicaloffpumpmitralvalverepairfollowingpriormitralvalvesurgeryacasereport
AT kammlerjuergen transapicaloffpumpmitralvalverepairfollowingpriormitralvalvesurgeryacasereport
AT steinwenderclemens transapicaloffpumpmitralvalverepairfollowingpriormitralvalvesurgeryacasereport
AT ziererandreasf transapicaloffpumpmitralvalverepairfollowingpriormitralvalvesurgeryacasereport