Cargando…
Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study
OBJECTIVE: The aim of this study was to develop and validate an MRI protocol based on a variable echo time (vTE) sensitive to the short T2* components of the sciatic nerve. MATERIALS AND METHODS: 15 healthy subjects (M/F: 9/6; age: 21–62) were scanned at 3T targeting the sciatic nerve at the thigh b...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154754/ https://www.ncbi.nlm.nih.gov/pubmed/32964300 http://dx.doi.org/10.1007/s10334-020-00886-w |
_version_ | 1783699061562408960 |
---|---|
author | Felisaz, Paolo Florent Belatti, Eugenio Deligianni, Xeni Bergsland, Niels Santini, Francesco Paoletti, Matteo Solazzo, Francesca Germani, Giancarlo Cortese, Andrea Vegezzi, Elisa Bieri, Oliver Bastianello, Stefano Pichiecchio, Anna |
author_facet | Felisaz, Paolo Florent Belatti, Eugenio Deligianni, Xeni Bergsland, Niels Santini, Francesco Paoletti, Matteo Solazzo, Francesca Germani, Giancarlo Cortese, Andrea Vegezzi, Elisa Bieri, Oliver Bastianello, Stefano Pichiecchio, Anna |
author_sort | Felisaz, Paolo Florent |
collection | PubMed |
description | OBJECTIVE: The aim of this study was to develop and validate an MRI protocol based on a variable echo time (vTE) sensitive to the short T2* components of the sciatic nerve. MATERIALS AND METHODS: 15 healthy subjects (M/F: 9/6; age: 21–62) were scanned at 3T targeting the sciatic nerve at the thigh bilaterally, using a dual echo variable echo time (vTE) sequence (based on a spoiled gradient echo acquisition) with echo times of 0.98/5.37 ms. Apparent T2* (aT2*) values of the sciatic nerves were calculated with a mono-exponential fit and used for data comparison. RESULTS: There were no significant differences in aT2* related to side, sex, age, and BMI, even though small differences for side were reported. Good-to-excellent repeatability and reproducibility were found for geometry of ROIs (Dice indices: intra-rater 0.68–0.7; inter-rater 0.70–0.72) and the related aT2* measures (intra-inter reader ICC 0.95–0.97; 0.66–0.85) from two different operators. Side-related signal-to-noise-ratio non-significant differences were reported, while contrast-to-noise-ratio measures were excellent both for side and echo. DISCUSSION: Our study introduces a novel MR sequence sensitive to the short T2* components of the sciatic nerve and may be used for the study of peripheral nerve disorders. |
format | Online Article Text |
id | pubmed-8154754 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-81547542021-06-01 Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study Felisaz, Paolo Florent Belatti, Eugenio Deligianni, Xeni Bergsland, Niels Santini, Francesco Paoletti, Matteo Solazzo, Francesca Germani, Giancarlo Cortese, Andrea Vegezzi, Elisa Bieri, Oliver Bastianello, Stefano Pichiecchio, Anna MAGMA Research Article OBJECTIVE: The aim of this study was to develop and validate an MRI protocol based on a variable echo time (vTE) sensitive to the short T2* components of the sciatic nerve. MATERIALS AND METHODS: 15 healthy subjects (M/F: 9/6; age: 21–62) were scanned at 3T targeting the sciatic nerve at the thigh bilaterally, using a dual echo variable echo time (vTE) sequence (based on a spoiled gradient echo acquisition) with echo times of 0.98/5.37 ms. Apparent T2* (aT2*) values of the sciatic nerves were calculated with a mono-exponential fit and used for data comparison. RESULTS: There were no significant differences in aT2* related to side, sex, age, and BMI, even though small differences for side were reported. Good-to-excellent repeatability and reproducibility were found for geometry of ROIs (Dice indices: intra-rater 0.68–0.7; inter-rater 0.70–0.72) and the related aT2* measures (intra-inter reader ICC 0.95–0.97; 0.66–0.85) from two different operators. Side-related signal-to-noise-ratio non-significant differences were reported, while contrast-to-noise-ratio measures were excellent both for side and echo. DISCUSSION: Our study introduces a novel MR sequence sensitive to the short T2* components of the sciatic nerve and may be used for the study of peripheral nerve disorders. Springer International Publishing 2020-09-22 2021 /pmc/articles/PMC8154754/ /pubmed/32964300 http://dx.doi.org/10.1007/s10334-020-00886-w Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Article Felisaz, Paolo Florent Belatti, Eugenio Deligianni, Xeni Bergsland, Niels Santini, Francesco Paoletti, Matteo Solazzo, Francesca Germani, Giancarlo Cortese, Andrea Vegezzi, Elisa Bieri, Oliver Bastianello, Stefano Pichiecchio, Anna Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title | Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title_full | Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title_fullStr | Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title_full_unstemmed | Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title_short | Variable echo time imaging for detecting the short T2* components of the sciatic nerve: a validation study |
title_sort | variable echo time imaging for detecting the short t2* components of the sciatic nerve: a validation study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154754/ https://www.ncbi.nlm.nih.gov/pubmed/32964300 http://dx.doi.org/10.1007/s10334-020-00886-w |
work_keys_str_mv | AT felisazpaoloflorent variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT belattieugenio variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT deligiannixeni variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT bergslandniels variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT santinifrancesco variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT paolettimatteo variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT solazzofrancesca variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT germanigiancarlo variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT corteseandrea variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT vegezzielisa variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT bierioliver variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT bastianellostefano variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy AT pichiecchioanna variableechotimeimagingfordetectingtheshortt2componentsofthesciaticnerveavalidationstudy |