Cargando…
Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads
We evaluated the clinical and radiographic outcomes of femoral head penetration and total hip arthroplasties with untreated and poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted highly cross-linked polyethylene (HXLPE) acetabular liners against 26-, 28-, and 32-mm cobalt–chromium alloy...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Japan
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154771/ https://www.ncbi.nlm.nih.gov/pubmed/33449228 http://dx.doi.org/10.1007/s10047-020-01246-0 |
_version_ | 1783699065554337792 |
---|---|
author | Mouri, Kanto Karita, Tatsuro |
author_facet | Mouri, Kanto Karita, Tatsuro |
author_sort | Mouri, Kanto |
collection | PubMed |
description | We evaluated the clinical and radiographic outcomes of femoral head penetration and total hip arthroplasties with untreated and poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted highly cross-linked polyethylene (HXLPE) acetabular liners against 26-, 28-, and 32-mm cobalt–chromium alloy femoral heads 3 years after the index surgery. Three combinations of the articulating surfaces were evaluated in the present study: untreated or PMPC-grafted HXLPE liner against 26- or 28-mm femoral heads (n = 16, 24) [control (26 or 28 mm) and PMPC (26 or 28 mm)] and PMPC-grafted HXLPE liner against 32-mm femoral heads (n = 64) [PMPC (32 mm)]. The clinical outcomes improved at 3 years postoperatively for the groups. No periprosthetic osteolysis or acetabular component migration was detected, and no revision surgery was performed among the groups. The steady-state wear rate of the PMPC (26 or 28 mm) group (0.021 mm/year) was lower than that of the control (26 or 28 mm) group (− 0.015 mm/year); the steady-state wear was under the clinical threshold. In contrast, the steady-state wear rate of the PMPC (32 mm) group (-0.006 mm/year) showed no significant difference when compared to that of the PMPC (26 or 28 mm) group (p < 0.01). The results obtained in the present study clearly demonstrate that PMPC-grafting onto an HXLPE surface improved the wear resistance of acetabular liners, even when coupled with larger femoral heads. Although further follow-up evaluations are required, PMPC-grafted HXLPE acetabular liners may be a promising approach to extend the longevity of artificial joints. |
format | Online Article Text |
id | pubmed-8154771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Japan |
record_format | MEDLINE/PubMed |
spelling | pubmed-81547712021-06-01 Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads Mouri, Kanto Karita, Tatsuro J Artif Organs Original Article We evaluated the clinical and radiographic outcomes of femoral head penetration and total hip arthroplasties with untreated and poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC)-grafted highly cross-linked polyethylene (HXLPE) acetabular liners against 26-, 28-, and 32-mm cobalt–chromium alloy femoral heads 3 years after the index surgery. Three combinations of the articulating surfaces were evaluated in the present study: untreated or PMPC-grafted HXLPE liner against 26- or 28-mm femoral heads (n = 16, 24) [control (26 or 28 mm) and PMPC (26 or 28 mm)] and PMPC-grafted HXLPE liner against 32-mm femoral heads (n = 64) [PMPC (32 mm)]. The clinical outcomes improved at 3 years postoperatively for the groups. No periprosthetic osteolysis or acetabular component migration was detected, and no revision surgery was performed among the groups. The steady-state wear rate of the PMPC (26 or 28 mm) group (0.021 mm/year) was lower than that of the control (26 or 28 mm) group (− 0.015 mm/year); the steady-state wear was under the clinical threshold. In contrast, the steady-state wear rate of the PMPC (32 mm) group (-0.006 mm/year) showed no significant difference when compared to that of the PMPC (26 or 28 mm) group (p < 0.01). The results obtained in the present study clearly demonstrate that PMPC-grafting onto an HXLPE surface improved the wear resistance of acetabular liners, even when coupled with larger femoral heads. Although further follow-up evaluations are required, PMPC-grafted HXLPE acetabular liners may be a promising approach to extend the longevity of artificial joints. Springer Japan 2021-01-15 2021 /pmc/articles/PMC8154771/ /pubmed/33449228 http://dx.doi.org/10.1007/s10047-020-01246-0 Text en © Authors 2021, corrected publication 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Mouri, Kanto Karita, Tatsuro Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title | Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title_full | Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title_fullStr | Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title_full_unstemmed | Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title_short | Short-term clinical and radiographic outcomes of total hip arthroplasty with PMPC-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
title_sort | short-term clinical and radiographic outcomes of total hip arthroplasty with pmpc-grafted highly cross-linked polyethylene liners against 32-mm femoral heads |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8154771/ https://www.ncbi.nlm.nih.gov/pubmed/33449228 http://dx.doi.org/10.1007/s10047-020-01246-0 |
work_keys_str_mv | AT mourikanto shorttermclinicalandradiographicoutcomesoftotalhiparthroplastywithpmpcgraftedhighlycrosslinkedpolyethylenelinersagainst32mmfemoralheads AT karitatatsuro shorttermclinicalandradiographicoutcomesoftotalhiparthroplastywithpmpcgraftedhighlycrosslinkedpolyethylenelinersagainst32mmfemoralheads |