Cargando…

Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System

SIMPLE SUMMARY: Marking impalpable areas of breast cancer prior to surgery is an important part of the modern treatment of breast cancer. Traditionally, the target lesion would be marked by a wire just before surgery under image guidance and would help the surgeon locate the tumour during surgery. H...

Descripción completa

Detalles Bibliográficos
Autores principales: Wazir, Umar, Kasem, Iham, Michell, Michael J., Suaris, Tamara, Evans, David, Malhotra, Anmol, Mokbel, Kefah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8156313/
https://www.ncbi.nlm.nih.gov/pubmed/34067552
http://dx.doi.org/10.3390/cancers13102409
_version_ 1783699415611998208
author Wazir, Umar
Kasem, Iham
Michell, Michael J.
Suaris, Tamara
Evans, David
Malhotra, Anmol
Mokbel, Kefah
author_facet Wazir, Umar
Kasem, Iham
Michell, Michael J.
Suaris, Tamara
Evans, David
Malhotra, Anmol
Mokbel, Kefah
author_sort Wazir, Umar
collection PubMed
description SIMPLE SUMMARY: Marking impalpable areas of breast cancer prior to surgery is an important part of the modern treatment of breast cancer. Traditionally, the target lesion would be marked by a wire just before surgery under image guidance and would help the surgeon locate the tumour during surgery. However, this method has some drawbacks, such as patient discomfort, the risk of migration and dislodgement, and the need to couple surgical and radiological schedules. Therefore, there has been a growing interest in this system, thus supporting its potential. In this study, we have evaluated one such system, SAVI SCOUT(®), in 63 consecutive patients. Our experience with this system supported its potential role in modern breast surgery. ABSTRACT: Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT(®) system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0–210). The median deployment duration was 5 min (range: 1–15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0–20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15–55 min) for the therapeutic excision of malignancy and 17 min (range: 15–24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5–70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7–10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT(®) is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance.
format Online
Article
Text
id pubmed-8156313
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81563132021-05-28 Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System Wazir, Umar Kasem, Iham Michell, Michael J. Suaris, Tamara Evans, David Malhotra, Anmol Mokbel, Kefah Cancers (Basel) Article SIMPLE SUMMARY: Marking impalpable areas of breast cancer prior to surgery is an important part of the modern treatment of breast cancer. Traditionally, the target lesion would be marked by a wire just before surgery under image guidance and would help the surgeon locate the tumour during surgery. However, this method has some drawbacks, such as patient discomfort, the risk of migration and dislodgement, and the need to couple surgical and radiological schedules. Therefore, there has been a growing interest in this system, thus supporting its potential. In this study, we have evaluated one such system, SAVI SCOUT(®), in 63 consecutive patients. Our experience with this system supported its potential role in modern breast surgery. ABSTRACT: Wire-guided localisation (WGL) has been the mainstay for localising non-palpable breast lesions before excision. Due to its limitations, various wireless alternatives have been developed. In this prospective study, we evaluate the role of radiation-free wireless localisation using the SAVI SCOUT(®) system at the London Breast Institute. A total of 72 reflectors were deployed in 67 consecutive patients undergoing breast conserving surgery for non-palpable breast lesions. The mean interval between deployment and surgery for the therapeutic cases was 18.8 days (range: 0–210). The median deployment duration was 5 min (range: 1–15 min). The mean distance from the lesion was 1.1 mm (median distance: 0; range: 0–20 mm). The rate of surgical localisation and retrieval of the reflector was 98.6% and 100%, respectively. The median operating time was 28 min (range: 15–55 min) for the therapeutic excision of malignancy and 17 min (range: 15–24) for diagnostic excision. The incidence of reflector migration was 0%. Radial margin positivity in malignant cases was 7%. The median weight for malignant lesions was 19.6 g (range: 3.5–70 g). Radiologists and surgeons rated the system higher than WGL (93.7% and 98.6%, respectively; 60/64 and 70/71). The patient mean satisfaction score was 9.7/10 (n = 47, median = 10; range: 7–10). One instance of signal failure was reported. In patients who had breast MRI after the deployment of the reflector, the MRI void signal was <5 mm (n = 6). There was no specific technique-related surgical complication. Our study demonstrates that wire-free localisation using SAVI SCOUT(®) is an effective and time-efficient alternative to WGL with excellent physician and patient acceptance. MDPI 2021-05-17 /pmc/articles/PMC8156313/ /pubmed/34067552 http://dx.doi.org/10.3390/cancers13102409 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wazir, Umar
Kasem, Iham
Michell, Michael J.
Suaris, Tamara
Evans, David
Malhotra, Anmol
Mokbel, Kefah
Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title_full Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title_fullStr Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title_full_unstemmed Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title_short Reflector-Guided Localisation of Non-Palpable Breast Lesions: A Prospective Evaluation of the SAVI SCOUT(®) System
title_sort reflector-guided localisation of non-palpable breast lesions: a prospective evaluation of the savi scout(®) system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8156313/
https://www.ncbi.nlm.nih.gov/pubmed/34067552
http://dx.doi.org/10.3390/cancers13102409
work_keys_str_mv AT wazirumar reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT kasemiham reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT michellmichaelj reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT suaristamara reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT evansdavid reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT malhotraanmol reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem
AT mokbelkefah reflectorguidedlocalisationofnonpalpablebreastlesionsaprospectiveevaluationofthesaviscoutsystem