Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study
BACKGROUND: The aims of this pilot study were (1) to assess the efficacy of 3D-printed custom-made hemipelvic endoprosthesis in restoring the natural location of acetabulum for normal bodyweight transmission; (2) to evaluate the short-term function of the revision with this endoprosthesis and (3) to...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8157625/ https://www.ncbi.nlm.nih.gov/pubmed/34039325 http://dx.doi.org/10.1186/s12893-021-01257-5 |
_version_ | 1783699724982812672 |
---|---|
author | Wang, Jie Min, Li Lu, Minxun Zhang, Yuqi Lin, Jingqi Luo, Yi Zhou, Yong Tu, Chongqi |
author_facet | Wang, Jie Min, Li Lu, Minxun Zhang, Yuqi Lin, Jingqi Luo, Yi Zhou, Yong Tu, Chongqi |
author_sort | Wang, Jie |
collection | PubMed |
description | BACKGROUND: The aims of this pilot study were (1) to assess the efficacy of 3D-printed custom-made hemipelvic endoprosthesis in restoring the natural location of acetabulum for normal bodyweight transmission; (2) to evaluate the short-term function of the revision with this endoprosthesis and (3) to identify short-term complications associated with the use of this endoprosthesis. METHODS: Between February 2017 and December 2017, seven patients received revision with 3D-printed custom-made hemipelvic endoprosthesis. The body weight moment arm (BWMA) and cup height discrepancy (CHD) after primary and revisional surgery were analyzed to assess acetabulum location with plain radiography. After a median follow-up duration of 29 months (range 24–34), the function was evaluated with the Musculoskeletal Tumor Society (MSTS-93) score and Harris hip score (HHS). Complications were recorded by chart review. RESULTS: The acetabulum locations were deemed reasonable, as evaluated by median BWMA (primary vs. revision, 10 cm vs. 10 cm) and median CHD (primary vs. revision, 10 mm vs. 8 mm). The median MSTS-93 score and HHS score were 21 (range 18–23) and 78 (range 75–82) after the revision. No short or mid-term complication was observed in the follow-up of this series. CONCLUSIONS: Revision with 3D-printed custom-made hemipelvic endoprostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening and fracture of modular hemipelvic endoprosthesis. The revision surgery and appropriate rehabilitation program improved patients’ function to a median MSTS score of 22 and pain-free ambulation. The incidence of the complications was low via this individualized workflow. |
format | Online Article Text |
id | pubmed-8157625 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-81576252021-05-28 Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study Wang, Jie Min, Li Lu, Minxun Zhang, Yuqi Lin, Jingqi Luo, Yi Zhou, Yong Tu, Chongqi BMC Surg Research Article BACKGROUND: The aims of this pilot study were (1) to assess the efficacy of 3D-printed custom-made hemipelvic endoprosthesis in restoring the natural location of acetabulum for normal bodyweight transmission; (2) to evaluate the short-term function of the revision with this endoprosthesis and (3) to identify short-term complications associated with the use of this endoprosthesis. METHODS: Between February 2017 and December 2017, seven patients received revision with 3D-printed custom-made hemipelvic endoprosthesis. The body weight moment arm (BWMA) and cup height discrepancy (CHD) after primary and revisional surgery were analyzed to assess acetabulum location with plain radiography. After a median follow-up duration of 29 months (range 24–34), the function was evaluated with the Musculoskeletal Tumor Society (MSTS-93) score and Harris hip score (HHS). Complications were recorded by chart review. RESULTS: The acetabulum locations were deemed reasonable, as evaluated by median BWMA (primary vs. revision, 10 cm vs. 10 cm) and median CHD (primary vs. revision, 10 mm vs. 8 mm). The median MSTS-93 score and HHS score were 21 (range 18–23) and 78 (range 75–82) after the revision. No short or mid-term complication was observed in the follow-up of this series. CONCLUSIONS: Revision with 3D-printed custom-made hemipelvic endoprostheses benefited in reconstructing stable pelvic ring and natural bodyweight transmission for patients encountering the aseptic loosening and fracture of modular hemipelvic endoprosthesis. The revision surgery and appropriate rehabilitation program improved patients’ function to a median MSTS score of 22 and pain-free ambulation. The incidence of the complications was low via this individualized workflow. BioMed Central 2021-05-26 /pmc/articles/PMC8157625/ /pubmed/34039325 http://dx.doi.org/10.1186/s12893-021-01257-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Wang, Jie Min, Li Lu, Minxun Zhang, Yuqi Lin, Jingqi Luo, Yi Zhou, Yong Tu, Chongqi Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title | Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title_full | Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title_fullStr | Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title_full_unstemmed | Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title_short | Three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
title_sort | three-dimensional-printed custom-made hemipelvic endoprosthesis for the revision of the aseptic loosening and fracture of modular hemipelvic endoprosthesis: a pilot study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8157625/ https://www.ncbi.nlm.nih.gov/pubmed/34039325 http://dx.doi.org/10.1186/s12893-021-01257-5 |
work_keys_str_mv | AT wangjie threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT minli threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT luminxun threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT zhangyuqi threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT linjingqi threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT luoyi threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT zhouyong threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy AT tuchongqi threedimensionalprintedcustommadehemipelvicendoprosthesisfortherevisionoftheasepticlooseningandfractureofmodularhemipelvicendoprosthesisapilotstudy |