Cargando…

Engineering base-excised aptamers for highly specific recognition of adenosine

The DNA aptamer for adenosine and ATP has been used as a model system for developing analytical biosensors. For practical reasons, it is important to distinguish adenosine from ATP, although this has yet to be achieved despite extensive efforts made on selection of new aptamers. We herein report a s...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Yuqing, Liu, Biwu, Huang, Zhicheng, Liu, Juewen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Royal Society of Chemistry 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8157715/
https://www.ncbi.nlm.nih.gov/pubmed/34084332
http://dx.doi.org/10.1039/d0sc00086h
_version_ 1783699743544705024
author Li, Yuqing
Liu, Biwu
Huang, Zhicheng
Liu, Juewen
author_facet Li, Yuqing
Liu, Biwu
Huang, Zhicheng
Liu, Juewen
author_sort Li, Yuqing
collection PubMed
description The DNA aptamer for adenosine and ATP has been used as a model system for developing analytical biosensors. For practical reasons, it is important to distinguish adenosine from ATP, although this has yet to be achieved despite extensive efforts made on selection of new aptamers. We herein report a strategy of excising an adenine nucleotide from the backbone of a one-site adenosine aptamer, and the adenine-excised aptamer allowed highly specific binding of adenosine. Cognate analytes including AMP, ATP, guanosine, cytidine, uridine, and theophylline all failed to bind to the engineered aptamer according to the SYBR Green I (SGI) fluorescence spectroscopy and isothermal titration calorimetry (ITC) results. Our A-excised aptamer has two binding sites: the original aptamer binding site in the loop and the newly created one due to base excision from the DNA backbone. ITC demonstrated that the A-excised aptamer strand can bind to two adenosine molecules, with a K(d) of 14.8 ± 2.1 μM at 10 °C and entropy-driven binding. Since the wild-type aptamer cannot discriminate adenosine from AMP and ATP, we attributed this improved specificity to the excised site. Further study showed that these two sites worked cooperatively. Finally, the A-excised aptamer was tested in diluted fetal bovine serum and showed a limit of detection of 46.7 μM adenosine. This work provides a facile, cost-effective, and non-SELEX method to engineer existing aptamers for new features and better applications.
format Online
Article
Text
id pubmed-8157715
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-81577152021-06-02 Engineering base-excised aptamers for highly specific recognition of adenosine Li, Yuqing Liu, Biwu Huang, Zhicheng Liu, Juewen Chem Sci Chemistry The DNA aptamer for adenosine and ATP has been used as a model system for developing analytical biosensors. For practical reasons, it is important to distinguish adenosine from ATP, although this has yet to be achieved despite extensive efforts made on selection of new aptamers. We herein report a strategy of excising an adenine nucleotide from the backbone of a one-site adenosine aptamer, and the adenine-excised aptamer allowed highly specific binding of adenosine. Cognate analytes including AMP, ATP, guanosine, cytidine, uridine, and theophylline all failed to bind to the engineered aptamer according to the SYBR Green I (SGI) fluorescence spectroscopy and isothermal titration calorimetry (ITC) results. Our A-excised aptamer has two binding sites: the original aptamer binding site in the loop and the newly created one due to base excision from the DNA backbone. ITC demonstrated that the A-excised aptamer strand can bind to two adenosine molecules, with a K(d) of 14.8 ± 2.1 μM at 10 °C and entropy-driven binding. Since the wild-type aptamer cannot discriminate adenosine from AMP and ATP, we attributed this improved specificity to the excised site. Further study showed that these two sites worked cooperatively. Finally, the A-excised aptamer was tested in diluted fetal bovine serum and showed a limit of detection of 46.7 μM adenosine. This work provides a facile, cost-effective, and non-SELEX method to engineer existing aptamers for new features and better applications. The Royal Society of Chemistry 2020-02-10 /pmc/articles/PMC8157715/ /pubmed/34084332 http://dx.doi.org/10.1039/d0sc00086h Text en This journal is © The Royal Society of Chemistry https://creativecommons.org/licenses/by/3.0/
spellingShingle Chemistry
Li, Yuqing
Liu, Biwu
Huang, Zhicheng
Liu, Juewen
Engineering base-excised aptamers for highly specific recognition of adenosine
title Engineering base-excised aptamers for highly specific recognition of adenosine
title_full Engineering base-excised aptamers for highly specific recognition of adenosine
title_fullStr Engineering base-excised aptamers for highly specific recognition of adenosine
title_full_unstemmed Engineering base-excised aptamers for highly specific recognition of adenosine
title_short Engineering base-excised aptamers for highly specific recognition of adenosine
title_sort engineering base-excised aptamers for highly specific recognition of adenosine
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8157715/
https://www.ncbi.nlm.nih.gov/pubmed/34084332
http://dx.doi.org/10.1039/d0sc00086h
work_keys_str_mv AT liyuqing engineeringbaseexcisedaptamersforhighlyspecificrecognitionofadenosine
AT liubiwu engineeringbaseexcisedaptamersforhighlyspecificrecognitionofadenosine
AT huangzhicheng engineeringbaseexcisedaptamersforhighlyspecificrecognitionofadenosine
AT liujuewen engineeringbaseexcisedaptamersforhighlyspecificrecognitionofadenosine