Cargando…

The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium

Background: Stress concentrated at an implant’s neck may affect bone-to-implant contact (BIC). The objective of this study was to evaluate four different implant neck designs using two different drilling protocols on the BIC. Methods: Ninety-six implants were inserted in 12 minipigs calvarium. Impla...

Descripción completa

Detalles Bibliográficos
Autores principales: Cohen, Omer, Bosshardt, Dieter D., Weinberg, Evegeny, Slutzkey, Gil, Moses, Ofer
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8158354/
https://www.ncbi.nlm.nih.gov/pubmed/34070127
http://dx.doi.org/10.3390/ma14102645
_version_ 1783699868947054592
author Cohen, Omer
Bosshardt, Dieter D.
Weinberg, Evegeny
Slutzkey, Gil
Moses, Ofer
author_facet Cohen, Omer
Bosshardt, Dieter D.
Weinberg, Evegeny
Slutzkey, Gil
Moses, Ofer
author_sort Cohen, Omer
collection PubMed
description Background: Stress concentrated at an implant’s neck may affect bone-to-implant contact (BIC). The objective of this study was to evaluate four different implant neck designs using two different drilling protocols on the BIC. Methods: Ninety-six implants were inserted in 12 minipigs calvarium. Implants neck designs evaluated were: type 1–6 coronal flutes (CFs), 8 shallow microthreads (SMs); type 2–6 CFs,4 deep microthreads (DMs); type 3–4 DMs; type 4–2 CFs, 8 SMs. Two groups of forty-eight implants were inserted with a final drill diameter of 2.8 mm (DP1) or 3.2 mm (DP2). Animals were sacrificed after 1 and 3 months, total-BIC (t-BIC) and coronal-BIC (c-BIC) were evaluated by nondecalcified histomorphometry analysis. Results: At 1 month, t-BIC ranged from 85–91% without significant differences between implant types or drilling protocol. Flutes on the coronal aspect impaired the BIC at 3 m. c-BIC of implant types with 6 CFs was similar and significantly lower than that of implant types 3 and 4. c-BIC of implant type 4 with SMs was highest of all implant types after both healing periods. Conclusions: BIC was not affected by the drilling protocol. CFs significantly impaired the -BIC. Multiple SMs were associated with greater c-BIC.
format Online
Article
Text
id pubmed-8158354
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-81583542021-05-28 The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium Cohen, Omer Bosshardt, Dieter D. Weinberg, Evegeny Slutzkey, Gil Moses, Ofer Materials (Basel) Article Background: Stress concentrated at an implant’s neck may affect bone-to-implant contact (BIC). The objective of this study was to evaluate four different implant neck designs using two different drilling protocols on the BIC. Methods: Ninety-six implants were inserted in 12 minipigs calvarium. Implants neck designs evaluated were: type 1–6 coronal flutes (CFs), 8 shallow microthreads (SMs); type 2–6 CFs,4 deep microthreads (DMs); type 3–4 DMs; type 4–2 CFs, 8 SMs. Two groups of forty-eight implants were inserted with a final drill diameter of 2.8 mm (DP1) or 3.2 mm (DP2). Animals were sacrificed after 1 and 3 months, total-BIC (t-BIC) and coronal-BIC (c-BIC) were evaluated by nondecalcified histomorphometry analysis. Results: At 1 month, t-BIC ranged from 85–91% without significant differences between implant types or drilling protocol. Flutes on the coronal aspect impaired the BIC at 3 m. c-BIC of implant types with 6 CFs was similar and significantly lower than that of implant types 3 and 4. c-BIC of implant type 4 with SMs was highest of all implant types after both healing periods. Conclusions: BIC was not affected by the drilling protocol. CFs significantly impaired the -BIC. Multiple SMs were associated with greater c-BIC. MDPI 2021-05-18 /pmc/articles/PMC8158354/ /pubmed/34070127 http://dx.doi.org/10.3390/ma14102645 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cohen, Omer
Bosshardt, Dieter D.
Weinberg, Evegeny
Slutzkey, Gil
Moses, Ofer
The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title_full The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title_fullStr The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title_full_unstemmed The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title_short The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium
title_sort effect of coronal implant design and drilling protocol on bone-to-implant contact: a 3-month study in the minipig calvarium
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8158354/
https://www.ncbi.nlm.nih.gov/pubmed/34070127
http://dx.doi.org/10.3390/ma14102645
work_keys_str_mv AT cohenomer theeffectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT bosshardtdieterd theeffectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT weinbergevegeny theeffectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT slutzkeygil theeffectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT mosesofer theeffectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT cohenomer effectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT bosshardtdieterd effectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT weinbergevegeny effectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT slutzkeygil effectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium
AT mosesofer effectofcoronalimplantdesignanddrillingprotocolonbonetoimplantcontacta3monthstudyintheminipigcalvarium