Cargando…

Spray coagulation with snare-tip versus argon plasma coagulation: An ex vivo study evaluating tissue effects

Background and study aims  Argon plasma coagulation (APC) is an effective and safe modality for many gastrointestinal conditions requiring hemostasis and/or ablation. However, it can be quite costly. A potentially more cost-effective alternative is snare-tip spray coagulation (SC). This study aimed...

Descripción completa

Detalles Bibliográficos
Autores principales: Fetz, Andrew, Farnell, David, Irani, Shayan, Gan, S. Ian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2021
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8159595/
https://www.ncbi.nlm.nih.gov/pubmed/34079859
http://dx.doi.org/10.1055/a-1373-4162
Descripción
Sumario:Background and study aims  Argon plasma coagulation (APC) is an effective and safe modality for many gastrointestinal conditions requiring hemostasis and/or ablation. However, it can be quite costly. A potentially more cost-effective alternative is snare-tip spray coagulation (SC). This study aimed to determine whether SC would be a safe and effective alternative to APC using an ex-vivo model. Methods  Using two resected porcine stomach, 36 randomized gastric areas were ablated for 2 seconds with either APC at 1.0 L/min 20 W (APC20) and 1.4 L/min 40 W (APC40) or SC with Effect 2 60 W (SC60) and 80 W (SC80) from 3 mm. Extent of tissue injury was then analyzed histopathologically. Results  The mean coagulation depth was 790 ± 159 µm and 825 ± 467 µm for SC60 (n = 9) and SC80 (n = 8), respectively. This was compared to 539 ± 151 µm for APC20 (n = 8) and 779 ± 267 µm for APC40 (n = 9). Mean difference (MD) in coagulation depth between SC60 and APC40 was 12 µm (95 % confidence interval [CI], –191 to 214 µm; P  = 0.91) and was 47 µm (95 %CI, –162 to 255 µm; P  = 0.81) between SC80 and APC40. There was a greater depth of injury with APC40 (MD, 240 µm; 95 %CI, 62 to 418 µm; P  = 0.04) and with SC60 (MD, 252 µm; 95 %CI, 141 to 362 µm; P  = 0.004) when compared to APC20. Mean cross-sectional area of coagulation was 2.39 ± 0.852 mm² for SC60 and 2.54 ± 1.83 mm² for SC80 compared to 1.22 ± 0.569 mm² for APC20 and 1.99 ± 0.769 mm² for APC40. Seventy-eight percent reached the muscularis mucosa (MM) and 11 % the submucosa in the SC60 group compared to 50 % and 38 % in SC80 and 56 % and 11 % in APC40, respectively. Thirty-eight percent of APC20 specimens reached the MM. The muscularis propria was unaffected. Conclusions  This small ex-vivo study suggests that SC60 and SC80 may be safe alternatives to APC40 with comparable coagulation depths and area effects.