Cargando…

Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors

PURPOSE: To evaluate diagnostic performance and safety of ultrasound-guided needle biopsy in the diagnosis of peripheral pulmonary nodules (PPLs) ≤ 2 cm, and the influence factors of sample adequacy and safety. MATERIALS AND METHODS: 194 patients (99 men, 95 women; mean age, 56.2 ± 13.7 years) who r...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Weijun, Ye, Jieyi, Qiu, Yide, Peng, Weiwei, Lan, Ninghui, Huang, Ting, Ou, Yinghui, Deng, Xiaoyun, Li, Yingjia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160365/
https://www.ncbi.nlm.nih.gov/pubmed/34055640
http://dx.doi.org/10.3389/fonc.2021.671884
_version_ 1783700269856456704
author Huang, Weijun
Ye, Jieyi
Qiu, Yide
Peng, Weiwei
Lan, Ninghui
Huang, Ting
Ou, Yinghui
Deng, Xiaoyun
Li, Yingjia
author_facet Huang, Weijun
Ye, Jieyi
Qiu, Yide
Peng, Weiwei
Lan, Ninghui
Huang, Ting
Ou, Yinghui
Deng, Xiaoyun
Li, Yingjia
author_sort Huang, Weijun
collection PubMed
description PURPOSE: To evaluate diagnostic performance and safety of ultrasound-guided needle biopsy in the diagnosis of peripheral pulmonary nodules (PPLs) ≤ 2 cm, and the influence factors of sample adequacy and safety. MATERIALS AND METHODS: 194 patients (99 men, 95 women; mean age, 56.2 ± 13.7 years) who received biopsy for PPLs ≤ 2 cm between January 2014 to January 2019 were included. Variables including patient demographics, lesion location, lesion size, presence of lesion necrosis, presence of emphysema on CT, patient position, biopsy needle size and number of needle passes were recorded. Univariate analysis and multivariate logistic regression analysis were performed to explore the influence factor of sample adequacy and safety. RESULTS: Biopsy specimens were adequate for diagnosis in 161/194 (83%) cases; the diagnostic accuracy was 81.4% (158/194). The overall complication rate was 8.8% (17/194), including pneumothorax, hemoptysis and pleural effusion, which occurred in 2.1% (4/194), 5.2% (10/194), and 1.5% (3/194) of patients, respectively. The incidence of pneumothorax in the 16-gauge-needle group were significantly higher than that of the 18-gauge-needle group (5.6% vs 0%, P=0.018). Adequate sampling of 16-gauge and 18-gauge needles were achieved in 90.3%(65/72) and 78.7%(96/122) cases, respectively. Multivariate logistic regression analysis revealed needle size (16-gauge vs 18-gauge) was an independent influence factors of sample adequacy (P=0.015, odds ratio=3.419). A receiver operating characteristic curve was plotted and the area under the curve was 0.774. CONCLUSION: US-guided percutaneous needle biopsy is a feasible and safe technique for small PPLs ≤ 2 cm. Needle size is an independent influence factor of sample adequacy and post-procedure pneumothorax. Sixteen-gauge needle has the advantage of achieving adequate sample for pathological analysis, though the risk of pneumothorax should be alerted.
format Online
Article
Text
id pubmed-8160365
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-81603652021-05-29 Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors Huang, Weijun Ye, Jieyi Qiu, Yide Peng, Weiwei Lan, Ninghui Huang, Ting Ou, Yinghui Deng, Xiaoyun Li, Yingjia Front Oncol Oncology PURPOSE: To evaluate diagnostic performance and safety of ultrasound-guided needle biopsy in the diagnosis of peripheral pulmonary nodules (PPLs) ≤ 2 cm, and the influence factors of sample adequacy and safety. MATERIALS AND METHODS: 194 patients (99 men, 95 women; mean age, 56.2 ± 13.7 years) who received biopsy for PPLs ≤ 2 cm between January 2014 to January 2019 were included. Variables including patient demographics, lesion location, lesion size, presence of lesion necrosis, presence of emphysema on CT, patient position, biopsy needle size and number of needle passes were recorded. Univariate analysis and multivariate logistic regression analysis were performed to explore the influence factor of sample adequacy and safety. RESULTS: Biopsy specimens were adequate for diagnosis in 161/194 (83%) cases; the diagnostic accuracy was 81.4% (158/194). The overall complication rate was 8.8% (17/194), including pneumothorax, hemoptysis and pleural effusion, which occurred in 2.1% (4/194), 5.2% (10/194), and 1.5% (3/194) of patients, respectively. The incidence of pneumothorax in the 16-gauge-needle group were significantly higher than that of the 18-gauge-needle group (5.6% vs 0%, P=0.018). Adequate sampling of 16-gauge and 18-gauge needles were achieved in 90.3%(65/72) and 78.7%(96/122) cases, respectively. Multivariate logistic regression analysis revealed needle size (16-gauge vs 18-gauge) was an independent influence factors of sample adequacy (P=0.015, odds ratio=3.419). A receiver operating characteristic curve was plotted and the area under the curve was 0.774. CONCLUSION: US-guided percutaneous needle biopsy is a feasible and safe technique for small PPLs ≤ 2 cm. Needle size is an independent influence factor of sample adequacy and post-procedure pneumothorax. Sixteen-gauge needle has the advantage of achieving adequate sample for pathological analysis, though the risk of pneumothorax should be alerted. Frontiers Media S.A. 2021-05-14 /pmc/articles/PMC8160365/ /pubmed/34055640 http://dx.doi.org/10.3389/fonc.2021.671884 Text en Copyright © 2021 Huang, Ye, Qiu, Peng, Lan, Huang, Ou, Deng and Li https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Huang, Weijun
Ye, Jieyi
Qiu, Yide
Peng, Weiwei
Lan, Ninghui
Huang, Ting
Ou, Yinghui
Deng, Xiaoyun
Li, Yingjia
Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title_full Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title_fullStr Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title_full_unstemmed Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title_short Ultrasound-Guided Percutaneous Core Needle Biopsy of Peripheral Pulmonary Nodules ≤ 2 cm: Diagnostic Performance, Safety and Influence Factors
title_sort ultrasound-guided percutaneous core needle biopsy of peripheral pulmonary nodules ≤ 2 cm: diagnostic performance, safety and influence factors
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8160365/
https://www.ncbi.nlm.nih.gov/pubmed/34055640
http://dx.doi.org/10.3389/fonc.2021.671884
work_keys_str_mv AT huangweijun ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT yejieyi ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT qiuyide ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT pengweiwei ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT lanninghui ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT huangting ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT ouyinghui ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT dengxiaoyun ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors
AT liyingjia ultrasoundguidedpercutaneouscoreneedlebiopsyofperipheralpulmonarynodules2cmdiagnosticperformancesafetyandinfluencefactors